Safety Information
IMPORTANT
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE COMMENCING INSTALLATION.
- READ THE SAFETY INSTRUCTIONS ON PAGE 2 OF THE SENTINEL KINETIC MVHR INSTALLATION & COMMISSIONING AND OPERATION & MONITORING DOCUMENTS.
- IF THE EXTRACTOR HOOD IS INSTALLED IN A ROOM CONTAINING A FUEL-BURNING APPLIANCE, THE INSTALLER MUST ENSURE THAT AIR REPLACEMENT IS ADEQUATE FOR BOTH THE EXTRACTOR HOOD FAN AND THE FUEL-BURNING APPLIANCE.
- DO NOT CONNECT THE EXTRACTOR HOOD DUCTING TO CHIMNEYS, FLUES OR AIR DUCTS SERVING THE ROOM.
- DO NOT SITE WHERE AMBIENT TEMPERATURES ARE LIKELY TO EXCEED 50°C. DO NOT DO ANY FLAMBÉ COOKING UNDERNEATH THE HOOD. WHEN FRYING, NEVER LEAVE THE PAN UNATTENDED IN CASE OF FIRE. THIS APPLIANCE IS NOT SUITABLE FOR USE ABOVE AN EYE LEVEL GRILL.
- WARNING: FAILURE TO COMPLY WITH THE CLEANING INSTRUCTIONS MAY RESULT IN A RISK OF FIRE. THE APPLIANCE EFFICIENCY DEPENDS ON THE CONDITION OF THE FILTERS.
- All regulations and requirements MUST be strictly followed to prevent hazards to life and property both during and after installation, and during any subsequent servicing and maintenance.
Disposal
♻️ This product should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority for recycling advice.
About this Document
Contents
- Product Description: Pull-out System Hood, User Information
- Technical Specification: Pull-out System Cooker Hood Technical Specification
- Installation: Overview, Before Installing the Unit, Unit Installation, Fitting the Cooker Hood to the Metal Duct Unit, Attach Ducting, Electrical Installation, Maintenance, Cooker Hood Cleaning Interval, Removing Filters, Spares
Product Description
Pull-out System Hood
The Vent-Axia Pull-out System Hood unit is a Cooker Hood designed for use with Vent-Axia's residential MVHR & MEV units in the energy efficient ventilation of houses and similar dwellings; conforming to the latest requirements of the Building Regulations document F 2010. In case of a fire or severe overheating on the hob, the unit is fitted with an intumescent fire damper to close the duct as required by BRE Digest 398. The cooker hood is designed to be mounted in the kitchen above a cooker hob in a standard cupboard space. The unit connected to the cooker hood should be switched to boost mode by extending the cooker hood during cooking.
Models
- 407509 - White Pull-out System Hood
- 407206 - Aluminium Pull-out System Hood
User Information
Operation of Cooker Hood
The unit is operated in boost mode when the telescopic hood is pulled out. Close it to return the unit to its Normal Flow Rate.
Important Note: Do not hold on to or place any object on telescopic hood whilst it is open, as this can cause damage.
Operation of Cooker Hood Light
Access can be gained to the light switch when the telescopic hood is opened. The light may be left on with the hood closed if required. However, make sure you switch it off when you have finished using it.
Cleaning Instruction
Refer to page 9 of this document.
Technical Specification
Pull-out System Cooker Hood Technical Specification
Category | Specification |
---|---|
Power | |
AC Voltage Input | 220-240 V AC (single phase) |
AC Frequency Input | 50 Hz nominal |
Supply Fuse | 3 A (located in fused spur) |
Rated Power | Total 8W (2x4W cooker hood low energy lamps) |
Physical | |
Weight | 5.15 kg |
Spigot diameter | 125 mm |
Environmental | |
IP Rating | IP22 |
Operating Temperature | -10°C to +45°C |
Storage Temperature | -10°C to +45°C |
Storage Humidity | 0% to 95% RH |
Dimensions (mm)
Top View Diagram: Shows the dimensions of the cooker hood from above, with labels A through L indicating various measurements. Key dimensions include A (598mm), B (570mm), C (280mm), D (299mm), E (126mm), F (300mm), G (158mm), H (41mm), I (50mm), J (40mm), K (120mm), L (110mm).
Side View Diagram: Illustrates the cooker hood from the side, showing depth and height measurements.
Front View Diagram: Displays the front of the cooker hood, indicating width and mounting points.
Underneath of Cooker Hood: Indicates the underside of the cooker hood.
Vertical Distances from Hob: Shows required minimum vertical distances from the hob: 650mm for electric hobs and 750mm for gas hobs.
Installation
Overview
The following instructions are intended to help prevent potential hazards and should be carried out only by a qualified electrician and installer.
Before Installing the Unit
Inspect the Unit
When taking delivery of the unit, check the items delivered against the delivery note. Inspect the unit for damage in transit. If in doubt, contact Customer Services. The box containing the cooker hood should contain an accessory pack consisting of black protective box for cooker hood socket and plug connection, screws, cable receptors and product documentation.
Check Site Requirements and Safety Notices
Check that the physical and environmental conditions for the site meet, or exceed, the requirements detailed in the Technical Specification on page 5. Read and observe the safety notices listed in IMPORTANT on page 2.
Unit Installation
The Pull-Out System Hood is only suitable for installation above a domestic cooker or cooker hob. The unit with cooker hood must be sited a minimum of 650mm above an electric hob and 750mm above a gas hob. It will fit in a 600 mm (external) x 300 mm deep (internal) kitchen wall cupboard space above the hob. The wall should have sufficient strength to support the unit. Take into consideration the position of the electrical services. Ensure there is adequate access for installation, operation and maintenance. Do not use this unit as a support for any other equipment.
Front Panel Adjustment
The front panel of the Pull-Out System Hood is adjustable; allowing it to align with the cabinet above. To make this adjustment first remove the grease filters. There are three screws located on the inside of the unit behind the front panel, unscrewing these will allow the front panel to be adjusted. Tighten the screws when the panel is in the desired position.
Diagram showing screw locations for front panel adjustment on the inside of the unit.
Fitting the Cooker Hood to the Metal Duct Unit
- Before fitting the unit to the wall, unpack the cooker hood, locate the four self-cutting screws and protective box for the cooker hood cable plug and socket.
- Pull out the telescopic hood and remove the two metal filters by releasing the grey plastic springs and sliding. (See Figure 1: Telescopic extractor hood)
- Rest the unit on its back ready to connect the cooker hood to the bottom of metal ducting.
- First lead the cooker hood cable through the hole at the bottom of the metal duct adaptor (See Figure 2: Inserting with plug through the hole). Then align the cooker hood with the hole positions, then fix it to the metal duct unit using four screws provided.
- Connect the plug into the socket ensuring that the locating lugs align. It is important that the cable is routed away from the fire damper. For wiring the socket to the MVHR unit see the Electrical Installation section on page 8.
- Place the assembled socket and plug in the protective box provided (See Figure 3: Placing the socket and plug in the connection box). Ensure the grommet is lined up with the rib and tuck in cable assembly shown by arrow before putting the cover together. Put the boxes together and secure using the screws provided.
Mounting
- The Pull-Out System Hood fits in a 600mm wide by 300mm deep kitchen cupboard space. Carefully mark the location for the five wall mounting screws (See Figure 4: Screw locations for wall mounting).
- Drill and plug the holes.
- Screw the cooker hood to the wall.
- There are also holes that allow the hood to be secured to the inside of cupboard walls. Use these mounting holes as well to secure the hood to the cupboard (See Figure 5: Screw locations for cupboard mounting).
Figure 1: Telescopic extractor hood showing the pull-out mechanism.
Figure 2: Inserting the plug through the hole, illustrating cable routing.
Figure 3: Placing the socket and plug in the connection box, showing how the protective box is assembled.
Figure 4: Screw locations for wall mounting, detailing the positions for securing the hood to the wall.
Figure 5: Screw locations for cupboard mounting, showing additional holes for securing the hood to the inside of cupboard walls.
Attach Ducting
Attach rigid or flexible ducting to the spigot using a worm drive clip or suitable cable tie.
Electrical Installation
Electrical Installation Diagram: Shows the wiring connections from the power board to a 3-pole local isolator, and then to the socket and plug connection for the cooker hood. It illustrates the routing of the cooker hood cable.
Wiring to the socket Diagram: Details how to wire the socket from the rear, indicating connections for L (Brown), N (Purple), and LS (Blue) wires from the cooker hood plug.
Connecting to Sentinel Kinetic Unit
- Remove a blind grommet from the Cable Inlet plate and insert the 3 core cable from Cooker hood.
- Connect the 3 wires to the terminal block marked J12.
Close-up view of a terminal block (J12) where the 3-core cable from the cooker hood is connected.
Maintenance
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE.
Cooker Hood Cleaning Interval
Item | Action |
---|---|
Cooker Hood Filters | Clean Filters every six months or more frequently if the style of cooking requires it. For instructions on how to remove filters see below. |
Cooker Hood Adaptor | Switch off the unit at the wall isolator before cleaning any component. Remove cover and wipe the interior clean every six months or more frequently if the style of cooking requires it. After cleaning ensure that the cover is replaced correctly and screws tightened. Do not use water or spray cleaning agents for cleaning the space, however a damp or dry cloth may be used. |
Removing Filters
a) Rear Filter - To remove the rear filter grip and pull inwards the grey levers at either side and slide the filter forwards and downwards.
b) Front Filter - To remove the front filter grip and pull inwards the grey levers at either side and drop the filters downwards.
c) The filters can be washed in a dishwasher or soapy water. Thoroughly dry the filters and reassemble in reverse order.
Image of the cooker hood filters, showing their structure and how they are removed.
Spares
The following spares may be ordered from Vent-Axia:
Part No | Description |
---|---|
456510 | Thermal Cut-out Fuse |
476071 | Low Energy LED Lamp |
372778 | Light Cover |
372774 | Cooker hood filters (set of two) |
Contact Information
Vent-Axia
Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX.
UK NATIONAL CALL CENTRE, Newton Road, Crawley, West Sussex, RH10 9JA
SALES ENQUIRIES: Tel: 0844 8560590, Fax: 01293 565169
TECHNICAL SUPPORT: Tel: 0344 8560594, Fax: 01293 532814
For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX.
Document reference: 474525 D. © 2016 Vent-Axia Limited. All rights reserved.