Vent-Axia MultiVent Continuous Extract Ventilation

Product Description

Product Code: FAN7200

The MultiVent continuous extract ventilation is designed for the simultaneous ventilation of separate areas in the home and as a multipoint extraction system for a wide range of commercial applications. The units can be wall, ceiling or loft mounted. Where the ambient air has a high humidity content, condensate drains are provided.

Thank you for purchasing this quality MultiVent continuous extract ventilation system. To ensure correct function and safety, please read all instructions before using the product and keep all instructions for future reference.

⚠️ When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electrical shock and personal injury.

Specifications

Duct (mm)Max. Fan Watts (W)Max. Fan Pressure (Pa)Free Air Fan Performance (l/s)Free Air Fan Performance (m³/hr)Performance at 200 Pa (l/s)Minimum Specific Fan Power (W/l/s)Sound dB(A)
125mm & 150mm858101595721230.1452
SEC ClassValue AverageValue WarmValue ColdFactorControl TypologyMax. Leakage Rates Internal %Max. Leakage Rates External %Annual Electricity Consumption (kWh/a) AverageAnnual Electricity Consumption (kWh/a) WarmAnnual Electricity Consumption (kWh/a) ColdAnnual Heating Saved (kWh/a)
B-26.9-11.4-54.00.65Local Demand Control<5<50.628.312.855.4

Compliance: AS/NZS60335-2.80:2016

Typical Extraction Locations

The unit uses a highly efficient backward curved centrifugal motor impeller set and is designed for continuous 24-hour use. Four settable speeds can be configured to change based on an integrated sensor or separate switch inputs (not supplied). The unit will run at a normal flow rate until the humidity sensor or external switch input triggers a speed change. In the case of switched live and digital inputs, the units will perform a step change in speed. For analog inputs and humidity sensors, the unit can be programmed for a proportional response.

The extracted air is replaced through natural airflow via gaps around doors and windows, trickle inlet slots, or the Manrose Puro Filtered Passive Vent Kit (DCT4565) with typhoon cowl, which has an effective aerodynamic area of 3000mm² without the filter and 1400mm² with the filter fitted.

Puro Filtered Passive Vent Kit DCT4565Effective Aerodynamic Area
with Filterwithout Filter
1400mm²3000mm²
Diagram showing dimensions A-F for the Puro Filtered Passive Vent Kit. A=330mm, B=390mm, C=111mm, D=250mm, E=96mm, ØF=125mm.
SupplyMax. Operating TempIP RatingMotor HousingImpeller & Outer RotorWeatherproof CowlDucting
220-240V AC, 50Hz40°CIPX2Die Cast AluminiumPBT Plastic150mm Stainless SteelAluminium Foil

Safety Precautions

⚠️ CAUTION

⚠️ BEFORE INSTALLING THE MULTIVENT CONTINUOUS EXTRACT VENTILATION SYSTEM, MAKE SURE YOU HAVE TURNED OFF THE MAIN ELECTRICITY SUPPLY. DO NOT TURN IT BACK ON UNTIL THE MULTIVENT CONTINUOUS EXTRACT VENTILATION SYSTEM IS FULLY INSTALLED AND READY TO USE.

ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN IN ACCORDANCE WITH THE LATEST WIRING RULES AS/NZS3000.

IMPORTANT

Installation

Position the unit, taking into consideration the position of the rooms to be ventilated, the exhaust position and the electrical services. Ensure there is adequate access for installation and maintenance.

If the unit is sited in the heated void of the dwelling, a condensate drain should not be necessary. When sited in a roof cavity, consideration should be given to fitment of a condensate drain. Alternatively, the unit and ducting can be externally insulated to minimize condensation within the unit's housing.

Ducting Guidelines

To reduce system resistance in your duct system, and therefore lower speed, power consumption, and noise, follow these guidelines:

Diagram illustrating ducting principles. Shows a flexible ducting route with supports, sleeve, interior grille, exterior grille, airflow, sealant, cavity, and a preferred flexible ducting route. It also depicts peaks and troughs, restrictions, and indicates that the minimum bend radius (measured to the inside) should be at least 1x the duct diameter.

Mounting Instructions

Securely mount the unit through the mounting holes on the casing using appropriate fixings (not supplied) for the mounting substrate. Fixings must be capable of securing 4x the weight of the unit. Unit weight: 4.1kg. Anti-vibration mounts, acoustic mats, or rubber bushes can also be used. An installation example is shown below.

To maintain the IPx2 rating of the unit, it must not be mounted with the cover removal slots facing upwards (as indicated by the red arrows), or at an angle where they are visible from above. All other orientations are acceptable.

Diagram showing the main power connections and low voltage connections ports on the unit.

Installation Steps (Room Extraction Points)

Illustration of a house interior showing the MultiVent fan positioned centrally, with airflow arrows indicating extraction from various rooms including a kitchen, bathroom, and toilet. The main exhaust ducting is shown leading to an external cowl.
  1. Cut a 126mm (minimum) hole in the required locations in the kitchen (minimum 2m away from the stove top), bathroom, and toilet.
  2. Disassemble the 125mm diffusers (DCT0186) and mount the 125mm spigots to the ceiling in each location using the four screws supplied.
  3. Fit the diffuser escutcheon by pushing it into the spigot.
  4. Extend the 125mm aluminium foil ducting and slide the spigot collar over the ducting by approximately 150mm.
  5. Slide the 125mm aluminium foil ducting over the spigot.
  6. Slide the spigot collar over the ducting, pressing it firmly all the way down the spigot to clamp the aluminium foil ducting in place. To prevent the spigot being pushed out, have another person pushing up from below. Complete the other two rooms following the same instructions.

Installation Steps (Main Unit and Ducting)

A series of images showing the connection of a 125mm duct joiner to the exhaust port, fitting a 150mm to 125mm reducer, attaching 150mm aluminium foil ducting to a 150mm waterproof cowl, and routing the ducting through an external wall opening.
  1. Mount the 125mm duct joiner (DCT0037) to the exhaust port of the MultiVent.
  2. Fit the 150mm to 125mm reducer (DCT3239) to the 125mm duct joiner and tape both joints using the supplied duct tape.
  3. Fit the 150mm aluminium foil ducting (DCT0214) to the 150mm waterproof cowl with mesh (DCT3619) and tape it to the spigot.
  4. From outside the building, cut a 150mm (minimum) hole in the outside cladding of the home and push the 150mm ducting through the hole.
  5. Fit the waterproof cowl to the building exterior and then, from the roof space, pull the ducting taut and tape it off at the 150mm to 125mm reducer.
  6. Extend each length of the 125mm aluminium foil ducting, pulling it taut, and tape off the three extraction points to the MultiVent unit.
  7. Install electrical wiring as per page 3 of the instruction manual.

Electrical Connections

1. To remove the cover, use a coin or similar; depress the retaining tabs via the slots in the side of the unit.

2. With the power off, connect a suitable mains power cable (preferably to an existing lighting circuit) to the screw terminal block (L, N, Earth) connections. Use the cable clamps and clip provided to secure the lead.

3. Two mains voltage Live Switched (LS1 and LS2) connections are provided and can be used to trigger a change in speed. Common inputs would be from a bathroom lighting circuit. When commissioning the unit, a delay on timer and an overrun timer can be selected and adjusted in the software using the buttons and screen. See Commissioning section on page 10 of this document for details.

4. The switched live output (230V AC) from any other switch or controller (such as a simple latching pullcord or push button switch, humidistat, or PIR detector) can be connected to the LS terminal instead of connecting to a lighting circuit.

Diagram of the electrical terminal block with labels L, N, E, LS1, LS2, and NS. Below the terminals, a table lists the terminal number, description, and corresponding wire color or connection.
TerminalDescriptionConnectionTerminalDescriptionConnection
1L Live (220-240V AC)L3 (Brown)4LS1 Live Switched 1, (220-240V AC), isolatedL2 (Black)
2N NeutralN (Blue)5LS2 Live Switched 2 (220-240V AC), isolatedL1 (Grey)
3Protective EarthE (Green/Yellow)6NS Neutral Switched, isolatedLink to N

NOTE: LS1, LS2 and NS terminals are electrically isolated. If the LS connections are used, a connection must be made with the NS terminal. This can be via a jumper or dedicated neutral connection.

Low Voltage Connections

1. Important: Use 4-core, low voltage, twisted pair, telecoms type cable for accessories. Accessories are connected via the IO (Input Output) PCB; see the Low Voltage Connections diagram in the Main fitting and wiring guide.

Diagram of the Input Output (IO) PCB showing various connection points labeled A through P. A table details the Pos/Label, Description, and Action for each terminal, including 5V Output, RS485, Digital Inputs, Digital Outputs, and Analog Inputs.
Pos/LabelDescriptionAction
A (5V)5V Output, Max 250mARS485 communication to wired accessories. Data connection (B, C) if available. The 5V and Ground connections are available on all units.
B (A+)DataGo to Boost speed (Min.1V, max. 6V). The 5V output from the RS485 connection can be used as a power supply.
C (B-)DataGo to Low speed (Min.1V, max. 6V). The 5V output from the RS485 connection can be used as a power supply.
D (GND)Ground
E (COM)Digital input common
F (+)Digital input 2
G (COM)Digital input common
H (+)Digital input 1
I (COM)Digital output commonUnpowered Boost indicator Switch (switching 6V 50mA max)
J (+)Digital output 2
K (COM)Digital output commonUnpowered LED fault indicator switch (switching 6V 50mA max)
L (+)Digital output 1
M (+)Analog input 20-10V analogue input
N (GND)GroundTwo user settable voltage thresholds with two user settable actions. The unit will run at normal when supplied voltage is between the two thresholds.
O (+)Analog input 1
P (GND)Ground

2. RS485 Wired Inputs

The RS485 terminals are used to connect compatible sensors and switches. The connection allows sensors to be daisy-chained to simplify wiring. The maximum length of cable run is limited to 250m. Once accessories are wired to the unit, they must be paired to the unit to function correctly.

Schematic diagram illustrating a low voltage switch with options for 'BOOST' and 'LOW SPEED' control, connected to RS485 and digital input terminals.

Feature Descriptions

Comfort Mode

TriggerAction
LS input active less than 5 minutesNo action (continue to run at Normal speed)
LS input active more than 5 minutes but less than 20 minutesOnce LS input is removed, fan will run at user selected speed for the length of time LS was present plus the set over-run time (if over run is enabled).
LS input active more the 20 minutesUnit will Boost after 20mins. Once LS input is removed, fan will run at user selected speed for 20 minutes plus the set overrun time (if over run is enabled).

The above applies to all LS inputs. The times are not adjustable by the user.

Delay On: A delay can be set so that the unit will not respond to an input until after the set delay has elapsed; applies to LS inputs only.

Overrun Timer: The unit can be set to run for a defined period after the input is removed; applies to LS inputs only.

Humidity Control

Humidity – Rapid rise*: Rapid Rise humidity response functions to detect rapid rises in humidity when the ambient %RH is under the threshold setting. If a rapid rise is detected, the fan will boost until the humidity lowers again.

Humidity – Ambient response*: When ambient response is enabled, the threshold set point is modified based on the ambient temperature. This helps to prevent nuisance boosting of the unit as temperatures change during the day.

Humidity – Threshold*: The unit will boost when the RH is above the threshold set point.

Analogue and Digital Inputs

Both analogue inputs have adjustable low and high trigger voltages within the 0-10V range. The response to being above or below either of the threshold voltages is user settable. Note: The display doesn't show a decimal point; for example, a threshold voltage of 5.2V is displayed as “52” on the unit.

The unit can be set to change speed (selectable), based on whether the digital inputs are above or below the threshold voltage. See the table of Low Voltage Connections for details.

Display Lock

To protect the settings on the MultiVent unit, a pin code can be enabled via the main menu. Once the lock function has been enabled, the Pin code can be set. The 3-digit pin is A to F, 0 to 9, and the default is LoC.

Unit Adjustment

1. Commissioning and configuration on all products is supported by the 3-digit user interface and associated push buttons.

2. When powered on, the unit will display the firmware revision number. After a few seconds, the unit will display the first option in the menu structure.

3. The display will enter standby mode after 30 seconds; press the Mode button to turn the display back on.

4. Changes to the settings can be made via the + and – buttons. The Mode button will accept changes and move onto the next menu option.

5. When setting the speeds, there is an internal logic: Low < Normal < Boost < Purge. I.e., Boost is always higher than Normal.

6. The actions for each of the Live Switched (LS) inputs are selectable. The settings for delays and over-run timers are applicable to all inputs.

7. To restore factory settings, press and hold the “Mode” button for 10 seconds.

User Configurable Parameters

Display TextFunctionSelectionsDefault
L10Low Speed1 to 97% motor speed10%
n35Normal Speed2 to 98% motor speed35%
b70Boost Speed3 to 99% motor speed70%
P100Purge Speed4 to 100% motor speed100%
LS1Live Switch 1Low, boost or purge speedLow
LS2Live Switch 2Low, boost or purge speedBoost
LS3Live Switch 1 & 2Low, boost or purge speedPurge
c-nComfort ModeComfort mode - Yes or NoNo
d-nDelay OnDelay on - Yes or NoNo
d10Delay On TimeDelay to boost duration - 1 to 60 minutes10m
o-nOverrunOverrun - Yes or NoNo
o10Overrun TimeOverrun duration - 1 to 60 minutes10m
r-yHumidity - Rapid RiseRapid Rise Rapid rise - Yes or NoYes
A-nHumidity - Ambient ResponseAmbient response - Yes or NoNo
h70Humidity - Ambient Response ThresholdAmbient response threshold - 40 to 80% RH70%
C2bCO2 - Boost ThresholdBoost threshold 650 - 4950 PPM950
C2PCO2 - Purge ThresholdPurge threshold 700 - 5000 PPM2000
A1LAAnalogue 1 - Low ActionLow, normal, boost or purge speedLow
A1HAAnalogue 1 - High ActionLow, normal, boost or purge speedBoost
A1tLAnalogue 1 - Low ThresholdLow threshold - 1 - 9915
A1tHAnalogue 1 - High ThresholdHigh threshold - 1-9975
A2LAAnalogue 2 - Low ActionLow, normal, boost or purge speedLow
A2HAAnalogue 2 - High ActionLow, normal, boost or purge speedBoost
A2tLAnalogue 2 - Low ThresholdLow threshold - 1 - 9915
A2tHAnalogue 2 - High ThresholdHigh threshold - 1 - 9975
D1Digital input 1 - ActionLow, boost or purge speedLow
D2Digital input 2 - ActionLow, boost or purge speedBoost
unlUnlock CodeTurn the menu lock OFF/ON
PlnDisplay Pin3 characters A to 9LoC
dt30Display TimeAdjust display illumination period30 s
rotRotate DisplayInvert the displayrot
huHumidityShow the current internal humidity%
tuTemperatureShow the current internal temperature°C
CO2CO2Show the current CO2 levelPPM
endEndEnd of menu (loop to start)

Commissioning - Typical 3 Room System

This section provides an example of how to wire and control an MultiVent system hardwired to a Bathroom, Kitchen, and Toilet. The MultiVent will utilize Humidity – Rapid Rise in its response, and the 2 larger rooms (Bathroom and Kitchen) will also provide a PURGE speed function if these 2 rooms are switched on together.

Before commencing, please ensure that all power is OFF and that it is electrically safe before starting.

Wire the 230VAC connections as per the diagram below. Wire mains connections from a suitable source (lighting circuit) or add a new dedicated circuit from an RCD protected 10A MCB with the cable to L (live - BROWN), N (neutral - BLUE), and E (protective earth – GREEN/YELLOW). Wire a 230V connection from a switch located in the Bathroom that could be either a dedicated FAN switch (or a connection from a LIGHT switch) and connect the L (BROWN) wire back to LS1. Do the same from a switch located in the Kitchen and connect the L (BROWN) wire back to LS2. Hardwire a NEUTRAL LINK (BLUE or BLACK) from the N (neutral - BLUE) mains connection to the connection labelled NS (neutral switched).

Wiring diagram for a typical 3-room system. It shows the mains power connections (L, N, E) and switched live connections (LS1 from Bathroom, LS2 from Kitchen) feeding into the unit. A neutral link is shown connecting the N terminal to the NS terminal.

Toilet Control Wiring

For the toilet, the MultiVent will use its Extra Low Voltage connections for control. Using a short piece of wire, connect a 0.5mm (or similar sized wire) from the GND terminal at the RS485 connection to the COM terminal adjacent to DIN 2 (digital input 2) + connector. Using a twin red TPS cable, connect one RED core to the + connector at DIN 2 and connect the other RED core to the 5V terminal at the RS485 connection. Run the other end of the cable to the toilet FAN switch and connect the 2 red cores to the C (common) and the normally open (usually labelled 1) connections at this switch. See diagram below.

Diagram showing low voltage wiring for toilet control. It shows connections from the RS485 GND and 5V terminals to the toilet switch's common (C) and normally open (1) terminals, via digital input 2 (DIN 2).

Using instructions from the section “UNIT ADJUSTMENT”, make the following changes:

With this completed, the MultiVent, once switched ON, will operate in NORMAL speed (35%). When the bathroom FAN switch is turned on, the MultiVent will operate at BOOST (70%) speed clearing away steam and humidity. If the kitchen FAN switch is turned on, the MultiVent will operate at BOOST (70%). If both bathroom and kitchen FAN switches are turned on together, the MultiVent will operate at PURGE (100%) speed, helping to clear away steam and cooking odours. The toilet FAN switch will also turn the MultiVent on to BOOST (70%). Please note that only having the 2 larger rooms (bathroom and kitchen) switched on will activate PURGE (100%) speed.

Compliance

For compliance with G4/AS1 Clause 1.5: These applications are to be installed and maintained to the requirements of AS/NZS 3666.1 and AS/NZS 3666.2.

Fault Codes

If the MultiVent unit detects a fault, it will display an error message on the HMI display.

Fault CodeDescription
F01Control fault – Unit failed startup check
F02Motor Fault – No RPM
F03Humidity/Temp sensor Fault – No value
F04Temp or Humidity sensor connected via RF/RS485 is offline/Lost

Spare Parts

⚠️ WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING PART REPLACEMENT.

  1. Individual faulty parts should not be replaced due to complexity of assembly. Only the full scroll assembly is replaceable.
  2. To remove the scroll assembly, isolate the power, then use a coin or similar to depress the cover retention clips and remove the cover.
  3. Disconnect and remove the power supply and signal leads.
  4. Remove the scroll assembly by unscrewing the two screws and unclipping the clips in the opposite two corners and lift the scroll assembly out of the housing.
  5. The fan has sealed for life bearings, which do not require lubrication. Expected service life is at least 45,000 hours continuous running.
  6. Upon reassembly, check all fixings are tight and secure.
Models: FAN7200, FAN7200 Continuous Extract Ventilation System, Continuous Extract Ventilation System, Extract Ventilation System, Ventilation System, System

File Info : application/pdf, 12 Pages, 1.70MB

PDF preview unavailable. Download the PDF instead.

PUB1644 2210 FAN7200 MultiVent Kit Vent-Axi Installation Instructions

References

Adobe PDF Library 16.0.7 Adobe InDesign 17.4 (Windows)

Related Documents

PreviewVent-Axia MultiVent Continuous Extract Ventilation FAN7200 Installation Guide
Comprehensive installation instructions, technical specifications, and feature descriptions for the Vent-Axia MultiVent Continuous Extract Ventilation System (FAN7200). Covers setup, wiring, operation, and troubleshooting for residential and commercial applications.
PreviewVent-Axia VA150 Window Extract Fan Installation and Wiring Instructions
Comprehensive installation, wiring, and maintenance guide for the Vent-Axia VA150A and VA150P window extract fans, including product specifications and guarantee information.
PreviewVent-Axia Lo-Carbon MVDC & Sentinel Multivent Range: Installation and Wiring Instructions
Comprehensive installation and wiring guide for Vent-Axia's Lo-Carbon MVDC and Sentinel Multivent range of ventilation systems, covering setup, wiring, configuration, and troubleshooting.
PreviewVent-Axia Lo-Carbon Response 7 Home Owner Guide: Reduce Condensation and Mould
A comprehensive guide for homeowners on the Vent-Axia Lo-Carbon Response 7 ventilation system, explaining how it prevents condensation and mould, improves air quality, and its low running costs.
PreviewVent-Axia Centra Lo-Carbon SELV Extractor Fan Installation and Wiring Instructions
Comprehensive installation and wiring guide for the Vent-Axia Centra Lo-Carbon SELV 100mm continuous extract fan, covering safety, mounting, wiring, and setup for models 443175A, 443176A, 443177A, and 447128A.
PreviewVent-Axia Energysaver IVDC Vertical Discharge Roof Extract Fan - Technical Overview
Comprehensive technical overview of the Vent-Axia Energysaver IVDC Vertical Discharge Roof Extract Fan, detailing its energy-efficient EC/DC motor technology, performance specifications, dimensions, advanced control features, and suitability for non-residential ventilation applications.
PreviewVent-Axia Response SELV Continuous Extract Fan Installation and Wiring Instructions
Comprehensive installation, wiring, setup, and troubleshooting guide for the Vent-Axia Response SELV continuous extract fan, including technical specifications and safety information.
PreviewVent-Axia Lo-Carbon Revive Home Owner Guide
A guide for homeowners on the Vent-Axia Lo-Carbon Revive ventilation system, explaining its benefits for reducing condensation and mould, how it works, and its low running costs.