Lo-Carbon Sentinel Kinetic High Flow
Acoustic Enclosure option for reduced breakout noise
Acoustic Top Box option for reduced in-duct noise
Recognised in SAP PCDB
180mm/200mm spigots
Horizontal duct option for space-saving installations
High airflow, ideal for student accommodation clusters
Unique folding filter for removal when access is restricted
Integrated digital controller for simple and accurate commissioning
Plug and play controls; Humidistat
BMS connectivity
LS inputs (Light Switch)
Volt-free inputs
Increased Performance
The Sentinel Kinetic High Flow benefits from the latest high efficiency, backward curved impeller design, ensuring the lowest possible energy consumption, and an exceptional performance range covering small one-bed apartments to the largest of houses.
For scenarios where noise is a critical issue, an Acoustic Enclosure is available to reduce breakout noise and the Acoustic Top Box will reduce in-duct noise at key frequencies.
Care Homes & Student Accommodation
The Sentinel Kinetic High Flow is ideal for larger homes and multiple occupancy units such as care homes and student accommodation. Capable of 175 l/s at 150Pa, the unit can extract from up to fourteen bathrooms and a communal kitchen while still achieving almost 90% heat recovery. The fully automatic capability of the Kinetic range means that adequate ventilation is always achieved.
The Kinetic's BMS capability is also ideal for those commercial applications where landlords or property managers want to monitor and optimise building performance and maintenance. The Kinetic BMS can provide status information and its self-diagnostics can report if any fault is found.
Spigot Options
180mm/200mm Spigots may be re-positioned to give horizontal connection or a combination of vertical and horizontal connection.
Quick Change Filter
As many systems are placed within cupboards, the unique filter design folds as you remove it to ensure easy access in restricted spaces.
Integral Humidity Sensor
The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature.
Models
- Kinetic High Flow Right - Stock Ref: 408449
- Kinetic High Flow Right with Acoustic Top Box & Enclosure - Stock Ref: 479544
- Kinetic High Flow Right with Acoustic Top Box - Stock Ref: 479543
- Kinetic High Flow Right with Acoustic Enclosure - Stock Ref: 479542
- Kinetic High Flow Left - Stock Ref: 408451
- Kinetic High Flow Left with Acoustic Top Box & Enclosure - Stock Ref: 479547
- Kinetic High Flow Left with Acoustic Top Box - Stock Ref: 479546
- Kinetic High Flow Left with Acoustic Enclosure - Stock Ref: 479545
For further details, see Sentinel Kinetic Plus.
Accessories
- Wired Remote Controller - Stock Ref: 443283
- LED Alarm with 15m cable - Stock Ref: 448356
- Opto-coupler for volt-free BMS connection - Stock Ref: 447340
- ISO 45% Coarse (G3) 2x Filter - Stock Ref: 403702
- ISO ePM10 50% Pollen (M5) 1x Filter - Stock Ref: 444201
- Anti Vibration Mounts - Stock Ref: 68MP033G
- Acoustic Purge Fan - Stock Ref: 477988
- Acoustic Purge Fan XL - Stock Ref: 479829
SAP PCDB Test Results
SAP 2009 | Thermal Efficiency % | SFP (W/l/s) | SAP 2012 | Thermal Efficiency % | SFP (W/l/s) |
---|---|---|---|---|---|
K+1 | 88 | 0.65 | 88 | 0.58 | 34.1 |
K+2 | 88 | 0.54 | 90 | 0.55 | 27.9 |
K+3 | 90 | 0.52 | 91 | 0.60 | 25.1 |
K+4 | 90 | 0.55 | 91 | 0.69 | 43.7 |
K+5 | 91 | 0.6 | 90 | 0.78 | 34.3 |
K+6 | 91 | 0.66 | 90 | 0.92 | 34.8 |
K+7 | 90 | 0.74 | 90 | 1.09 | 51.7 |
SEC Rating
Model | SEC Class |
---|---|
Kinetic High Flow | A |
Performance
Graph showing airflow (l/s and m³/hr) versus static pressure (Pa) with various efficiency curves indicated.
Dimensions (mm)
Unit:
A | B | C | D | EØ | F | G | |
---|---|---|---|---|---|---|---|
785 | 635 | 722 | 550 | 180/200 | 520 | 275 |
Weight: 31kg
Acoustic Solution:
A | B | C | D | E | F | G | kg | kg | Spigot | |
---|---|---|---|---|---|---|---|---|---|---|
80 | 733 | 501 | 71 | 855 | 583 | 40 | 17 | 33 | 180 |
Diagrams showing unit dimensions and acoustic solution dimensions with labels for Acoustic Top Box and Acoustic Enclosure.
Sound Data (Unit only)
Flow % | Mode | 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1K | 2K | 4K | 8K | LwA | SPL dB(A) @3m |
---|---|---|---|---|---|---|---|---|---|---|---|
20 | Supply | 55.1 | 65.9 | 55.2 | 53.8 | 44.4 | 37.4 | 25.3 | 24.9 | 66.8 | 34.1 |
Extract | 58.2 | 57.4 | 48.0 | 45.6 | 43.8 | 34.5 | 20.0 | 24.5 | 61.3 | 27.9 | |
Breakout | 43.3 | 46.6 | 44.9 | 44.7 | 41.8 | 30.4 | 21.6 | 22.5 | 51.6 | 20 | |
40 | Supply | 63.1 | 69.0 | 67.1 | 64.0 | 55.0 | 51.6 | 39.7 | 32.4 | 64.2 | 43.7 |
Extract | 58.6 | 58.4 | 60.0 | 53.7 | 41.9 | 41.5 | 31.7 | 25.1 | 54.9 | 34.3 | |
Breakout | 55.4 | 49.6 | 60.6 | 53.8 | 46.5 | 41.5 | 33.2 | 27.4 | 55.4 | 34.8 | |
60 | Supply | 70.3 | 74.3 | 81.4 | 71.5 | 63.6 | 59.9 | 49.6 | 43.1 | 74.8 | 54.3 |
Extract | 64.4 | 64.2 | 72.6 | 59.1 | 48.7 | 45.7 | 37.8 | 29.3 | 64.9 | 44.4 | |
Breakout | 62.8 | 54.6 | 65.7 | 57.2 | 55.5 | 49.2 | 41.4 | 36.4 | 61.0 | 40.5 | |
80 | Supply | 75.3 | 77.9 | 88.1 | 78.7 | 68.4 | 65.1 | 56.0 | 50.1 | 81.4 | 60.9 |
Extract | 71.1 | 68.2 | 73.6 | 61.8 | 51.9 | 49.5 | 42.7 | 37.6 | 66.4 | 45.9 | |
Breakout | 66.2 | 59.0 | 73.4 | 61.8 | 57.0 | 54.6 | 47.3 | 43.1 | 66.8 | 46.2 | |
100 | Supply | 90.9 | 80.9 | 84.4 | 80.1 | 71.5 | 68.0 | 59.3 | 54.5 | 80.7 | 60.1 |
Extract | 92.4 | 71.8 | 78.1 | 67.4 | 54.9 | 51.5 | 44.6 | 41.4 | 72.2 | 48.8 | |
Breakout | 69.3 | 62.9 | 74.9 | 67.5 | 59.2 | 56.6 | 49.1 | 44.7 | 69.3 | 51.7 |
Sound Data (Unit with Acoustic Enclosure)
Flow % | Mode | 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1K | 2K | 4K | 8K | LwA | SPL dB(A) @3m |
---|---|---|---|---|---|---|---|---|---|---|---|
20 | Supply | 55.2 | 57.0 | 46.1 | 38.8 | 24.0 | 15.4 | 18.0 | 23.2 | 43.6 | 26.1 |
Extract | 50.4 | 53.6 | 37.0 | 32.3 | 18.2 | 15.1 | 18.0 | 23.2 | 38.7 | 21.2 | |
Breakout | 41.3 | 51.8 | 39.2 | 32.3 | 20.5 | 15.8 | 18.1 | 23.2 | 37.7 | 17.2 | |
40 | Supply | 64.1 | 59.6 | 59.7 | 51.9 | 35.5 | 22.8 | 19.9 | 23.5 | 53.3 | 35.8 |
Extract | 56.6 | 50.7 | 49.0 | 41.9 | 24.5 | 17.7 | 18.1 | 23.2 | 43.3 | 25.8 | |
Breakout | 46.7 | 50.5 | 53.0 | 44.8 | 32.2 | 22.2 | 18.5 | 23.3 | 45.6 | 25.1 | |
60 | Supply | 67.3 | 64.0 | 67.7 | 58.6 | 43.2 | 30.6 | 26.5 | 25.9 | 61.0 | 43.5 |
Extract | 61.6 | 56.7 | 55.5 | 49.0 | 32.2 | 25.3 | 19.7 | 23.4 | 50.2 | 32.7 | |
Breakout | 53.0 | 54.4 | 60.2 | 48.8 | 40.6 | 33.2 | 23.4 | 23.4 | 53.0 | 32.5 | |
80 | Supply | 70.3 | 67.7 | 74.6 | 61.8 | 48.5 | 36.2 | 33.0 | 31.4 | 67.5 | 50.0 |
Extract | 66.7 | 60.0 | 67.2 | 50.9 | 38.1 | 32.8 | 24.0 | 24.1 | 59.7 | 42.2 | |
Breakout | 58.0 | 58.0 | 64.7 | 52.4 | 45.7 | 39.9 | 31.2 | 24.3 | 58.7 | 40.2 | |
100 | Supply | 73.0 | 70.1 | 77.1 | 65.1 | 51.4 | 39.5 | 37.0 | 36.4 | 70.1 | 52.6 |
Extract | 69.6 | 62.5 | 67.3 | 56.2 | 41.7 | 37.0 | 28.1 | 25.3 | 60.5 | 43.0 | |
Breakout | 61.0 | 61.2 | 65.9 | 57.7 | 48.5 | 43.8 | 36.3 | 26.3 | 60.7 | 40.2 |
Tested according to BS EN 13141-7:2010. Breakout quoted spherical. Supply and Extract quoted hemispherical.
Consultant's Specification
Operation
The supply and extract ventilation unit shall be as Sentinel Kinetic High Flow as manufactured by Vent-Axia and shall be sized as indicated on the drawings and shall be in accordance with the particular specification.
Supply air to the room shall be pre-heated by the extract air via the integrated composite plastic counterflow heat recovery cell. The Sentinel Kinetic High Flow shall automatically vary the ventilation rate via EC/DC motors, as it receives signals from one of the optional interconnected sensors.
When a signal is received, the fans shall either vary their speed proportionally or on a trickle and boost principle.
The unit shall have the facility to commission the supply and extract fans individually via in-built minimum and maximum speed adjustment, or alternative wired remote control unit. The fans themselves shall have independent, infinitely variable speed control.
Unit Specification
The unit shall be manufactured with an ABS outer case construction, and incorporate a reversible core to allow for left or right hand mounting. The unit shall have a high efficiency composite plastic counterflow heat exchanger, supply and extract filters, automatic summer bypass, integral minimum and maximum infinitely variable speed controls with facia mounted failure indication.
The unit shall have low energy, high efficiency EC/DC fan/motor assemblies with sealed for life bearings. The impellers shall be high efficiency backward curved centrifugal type.
The unit shall have a heat exchanger cell with a thermal efficiency of up to 92% when tested to EN 308. This shall be protected by ISO 45% Coarse (G3) grade synthetic filters on supply and extract. Complete with a condensate drip tray and drain connection.
To reduce breakout noise, the MVHR unit shall be provided with an Acoustic Enclosure of steel construction lined with class '0' acoustic foam. To reduce in-duct noise, the top of the MVHR shall be fitted with an Acoustic Top Box to provide attenuation to the 4 ducts of the unit. This Acoustic Top Box shall be of steel construction lined with acoustic class 'O' foam with the MVHR spigots linked to the Top Box via 4 separate attenuated ducts. The acoustic enclosure and top box shall each be independently tested for noise to BS EN 13141-7.
The unit shall be constructed with a removable Core allowing full maintenance access. The removable Core shall provide access to the following:
- ✓ Supply and extract filter
- ✓ Heat exchanger
- ✓ Access to the electrical connections
Access shall be provided for wiring termination and setup/commissioning. The backlit LCD user interface therein may be duplicated for remote mounting if required.
Units shall be as manufactured by Vent-Axia Ltd.
The MVHR unit shall incorporate an Expanded Polystyrene (EPS) inner chassis with custom motor and impeller mounting features. The inner chassis will assist in reducing noise and act as a large anti-vibration mount to avoid transmission through to the back mounting plate or the base of the unit.
The MVHR unit shall be tested to ensure it meets the maximum allowable vibration of no more than 1mm/s, measured on the unit wall fixing points.
Sound tested to BS EN 13141-7:2010
Standard Controls
All Sentinel Kinetic units shall incorporate the following functions integrally mounted, pre-wired and factory fitted by the manufacturer:
- ✓ Integral infinitely variable fan speed control on supply and extract
- ✓ Integral min/max ventilation control/set point
- ✓ Integral BMS input/output interfaces - control and status indication
- ✓ Heating interlocks
- ✓ 0-10V proportional speed adjustment
- ✓ Volt free contacts
- ✓ 24V sensor supply
- ✓ Integral on/off or trickle boost function from remote switch, e.g. PIR occupancy detector
- ✓ Fully automatic summer bypass
- ✓ Switched Live input with adjustable 'delay-on' feature
- ✓ Fan failure or component failure indicated via individual fault code display
- ✓ Running time counter
- ✓ Control panel PIN number lock
- ✓ Automatic frost protection effective to -20°C
The unit shall incorporate an integral humidity sensor with the following features:
- Ambient Response: Raises the humidity trigger point as dwelling temperature reduces
- Rapid Response: Monitors the rate of change in humidity and triggers increased airflow even if the humidity trigger threshold is not reached
- Proportional Response: Incrementally increases the fan speed to reduce noise and reduce energy consumption
The unit shall be controlled by the 'Sentinel' control devices (enablers and sensors) as detailed in the schedule or on the drawings.
Tool free filter access
Mounting Option
Airflow Direction
[Diagram illustrating airflow directions for supply, extract, and optional acoustic ducting from different perspectives: Plan View, Front (RH), Front (LH)]
Electrical Connection
Please note: Electrical connection should be carried out by an appropriately qualified person and in accordance with current wiring regulations.
Trickle to Boost by two lighting circuits or Trickle/Boost Switch
File Info : application/pdf, 4 Pages, 414.85KB
DocumentDocumentRelated Documents
![]() |
Vent-Axia Sentinel Kinetic MVHR Installation and Commissioning Guide Comprehensive guide for installing and commissioning Vent-Axia Sentinel Kinetic Mechanical Ventilation with Heat Recovery (MVHR) units, covering safety, technical data, and operational setup for residential properties. |
![]() |
Sentinel Kinetic MVHR Range Quick Installation Guide A quick installation guide for Vent-Axia's Sentinel Kinetic MVHR range, detailing product descriptions, installation dimensions, and wiring diagrams. Includes contact information for BPC Ventilation. |
![]() |
Vent-Axia Lo-Carbon Sentinel Kinetic Advance MVHR System Detailed information on the Vent-Axia Lo-Carbon Sentinel Kinetic Advance, a next-generation heat recovery ventilation system offering high efficiency, low noise, and advanced control features for improved indoor air quality and comfort. |
![]() |
Vent-Axia Sentinel Kinetic MVHR Range: Installer & Homeowner Guide This guide provides essential information for installing and operating the Vent-Axia Sentinel Kinetic MVHR system. Learn about safety, maintenance, technical specifications, and benefits for homeowners and installers. |
![]() |
Vent-Axia Ventilation for New Build Residential Guide Comprehensive guide to ventilation solutions for new build residential properties from Vent-Axia, covering building regulations, product types, and installation best practices. |
![]() |
Vent-Axia Lo-Carbon Sentinel Multivent/Plus: Efficient MEV Ventilation Discover the Vent-Axia Lo-Carbon Sentinel Multivent/Plus, a high-efficiency mechanical extract ventilation (MEV) system designed for homes and commercial spaces. Features include low SFP, SAP PCDB recognition, and advanced control options for improved air quality and energy savings. |
![]() |
How to Clean the Vent-Axia MVHR Cell: A Step-by-Step Guide Learn how to effectively clean your Vent-Axia Mechanical Ventilation with Heat Recovery (MVHR) cell annually. This guide provides clear, step-by-step instructions and essential tips for maintaining your system. |
![]() |
Vent-Axia Lo-Carbon MVDC & Sentinel Multivent Range: Installation and Wiring Instructions Comprehensive installation and wiring guide for Vent-Axia's Lo-Carbon MVDC and Sentinel Multivent range of ventilation systems, covering setup, wiring, configuration, and troubleshooting. |