Quick guide to EB-Therm 205
Get started quickly and easily! Here you have a guide to the most important functions and settings, an introduction to the energy saving programs and an overview of the menu system. Always read the entire manual for complete product information.
Getting started with EB-Therm
This is what the display looks like when you first start EB-Therm.
The display features an 'On/off button' at the top. Below this, a large display shows '22.0°F'. To the right of the temperature display is the 'Temperature Selected control'. Beneath the temperature display are two circular buttons labeled with up and down arrows, identified as 'Arrow keys [▼ ▲]'. At the bottom is a circular button labeled 'Selection button [●]'.
Using the menu
To start the menu, press the 'On/off button'.
To scroll through the options, use the 'Arrow keys [▼ ▲]'.
To exit the menu, press the 'Selection button [●]' or wait 30 seconds for automatic exit.
Turning off and on
To put the unit in standby mode, press and hold the 'On/off button' for 1 second.
To turn the unit out of standby mode, press and hold the 'On/off button' for 1 second.
Note: The heat is not being regulated. The clock is running and any settings are saved in the memory.
Locking the keypad
To scroll through keypad lock options, use the 'Arrow keys [▼ ▲]'.
To lock the keypad, press the 'Selection button [●]' when 'LOCK' is displayed.
To unlock the keypad, press and hold the 'Selection button [●]' for 4 seconds when 'UNLOCK' is displayed.
Basic settings
Time and date
To be able to use all the functions, you need to set the time and date first.
The display shows 'SET' and '22.0°F'. Use the 'Arrow keys [▼ ▲]' to scroll to the correct time. Press the 'Selection button [●]' to confirm. Repeat the last two steps to set minutes, day, month, and year. The weekday is set automatically but not displayed.
Desired temperature
The display shows '22.0°F'. Use the 'Arrow keys [▼ ▲]' to adjust the temperature. Press the 'Selection button [●]' to confirm.
Show actual temperature
To lock buttons, press the 'On/off button'.
The display shows 'LOCK 22.0°F'. Use the 'Arrow keys [▼ ▲]' to select 'Temp. in the floor*'. The display then shows '23.5°F' with a floor symbol, indicating the floor temperature.
*If the thermostat is set to Floor thermostat. Otherwise the room temperature (R) is displayed.
The EB-Therm 205 can regulate the temperature in three different ways: a floor thermostat, a room thermostat, or a room and floor thermostat. This enables the comfort temperature and any flooring temperature requirements to be combined. If the floor sensor is connected when the thermostat is turned on for the first time, the floor thermostat is selected automatically. The room thermostat cannot be selected when the floor sensor is connected. The room and floor thermostat should be used in rooms with wooden flooring and in rooms with large windows that are exposed to solar insolation. Read more about the control functions and how you set them in the manual. Actual temperatures can be read at all times by following the above description.
Energy saving programs
Save energy cleverly and easily! With these programs, the heating is adapted to your actual needs and the heat is turned down when it isn't needed. There are two preset programme options, of which the Home Programme is adjustable:
- Preset for home environments ? The temperature is reduced automatically by 5°C (adjustable) during the following times: Monday-Friday, 8:30 am-3 pm (adjustable); Monday-Sunday, 11 pm-5 am (adjustable).
- Program for office environments ? The temperature is automatically reduced by 5°C at all times except for Monday-Friday, 6 am-6 pm.
Start/stop programs
To start a program, press the 'Selection button [●]' when the correct program symbol is flashing.
A symbol showing that a program is running will appear on the display.
*Stop program: Confirm when no symbol is flashing.
Sitemap of the menu
This is how the menu in EB-Therm 205 is structured. Here you can quickly see where all the functions and settings are.
- PROG Start/stop programs
- Home programs
- Office programs
- SET Various settings
- CLK Set time and date.
- S Turn off and on automatic change to DST
- RNF Set how the temperature is to be regulated. F (floor thermostat) – R (room thermostat) – R & F
- OH Set the temperature to restrict the floor sensor for R & F.
- DISP Set how time will be shown, 24- or 12-hour format.
- AF Turn off and turn on the adaptive function.
- SET Adjust preset times and temperatures in the home program.
- RST Reverts to factory settings and deletes all personal settings.
- END Exit the menu and return to basic mode.
- LOCK Locks the keypad
- END Exits the menu