Ebeco Thermoflex Underfloor Heating System
Installation Guide, Specifications, and Warranty
This document provides comprehensive information for the installation, use, and maintenance of Ebeco Thermoflex underfloor heating systems, including models Thermoflex Kit 200/500 and Thermoflex 45/60/120/160.
Welcome
Thank you for choosing Ebeco. We hope you will be happy with your underfloor heating system for many years to come. For the guarantee to apply, the product must be installed and used as described in this manual. It is therefore important that you read the manual.
If you have any questions, please contact Ebeco. Call +46 31 707 75 50 or send an email to info@ebeco.se. More information is available at ebeco.com.
Important Safety Information ⚠️
- The underfloor heating system is a high voltage system and must be installed according to applicable regulations by an authorised electrician.
- For the guarantee to apply, the guarantee certificate must be correctly and completely filled in, and signed by an authorised electrician.
- May only be installed indoors.
- The heating cable must not be cut. Furthermore, it may neither be crossed nor installed with spacing of less than 5 cm.
- The connection cable may be cut.
- The thermostat's sensor cable may be cut.
- The cable must be measured for resistance and insulation as per the instructions. Document the values in the Garantera Ebeco web app or in the guarantee certificate.
- Either a diagram or photo of the cable routing must be documented.
- The sign "Heating Cable Installed" must be posted at the main junction box.
- Heating must be regulated with Ebeco's EB-Therm thermostats.
- The system must be connected to 230 V via a 30-mA earth fault circuit breaker.
- The heating cable must not be run under stationary furnishings, such as kitchen counters, closets, inner walls, etc., as this produces elevated temperatures.
- In wet rooms, the heating cable must be run under a sealing layer.
- Wait 4 weeks after applying screed before turning on the heat to allow the screed to dry properly.
- In rooms with wooden floors, the Room and floor thermostat function must always be used.
- The maximum permissible heat resistance of the floor material is 0.16 m² K/W.
Installation Guide
Subflooring
The heating cable is laid on floor constructions of concrete, plaster, or chipboard and must then be screeded with a suitable levelling compound. Wooden and chipboard floors over joists spaced at more than 30 cm need to be strengthened to prevent cracks and tile detachment. Use Ebeco Thermo Board (see Energy Saving Tips and product's installation instructions). For uninsulated concrete floors against the ground, additional insulation is recommended, and the heating should not be switched off completely during summer to counteract moisture rising.
Flooring Materials
Thermoflex can be installed under tiles, natural stone, wood, laminate, and linoleum floors. When screeding, the heating cable must be laid in a minimum screed layer as follows:
- Tile/natural stone floor: 5 mm
- Wood/laminate flooring: 10 mm
- Linoleum: 15 mm
Refer to applicable industry regulations for detailed instructions on floor construction, screeding, sealing, tiling, and jointing.
Recommendations and Maximum Output
The room's heat requirement depends on its insulation level, air circulation, and outdoor temperature.
Heating Cable (for screed) | Recommended Output | Floor Material | Regulation | Subflooring |
---|---|---|---|---|
45-160 W/m² | Tile/natural stone: Max 160 W/m² | Room/Floor | Concrete: Max 160 W/m² | |
Wood/laminate/linoleum: Max 75 W/m² | Room + Floor | Combustible: Max 120 W/m² |
Industry guidelines for wood/laminate and linoleum on underfloor heating:
- General conditions: Maximum permissible surface temperature is 27°C, including under carpets and furniture.
- Coverage: Covering wood/laminate/linoleum floors laid on underfloor heating risks overtemperature in the floor or the room temperature becoming too low. Coverings include carpets, beds without ventilated bases, bookshelves with fully-covering bottoms, kitchen cabinets, etc.
Positioning of Sensor Cable and Connection Cable
1. The Thermoflex Kit includes a flexible conduit with a sealed end. Insert the thermostat's sensor cable into this conduit.
2. The underfloor heating cable has a 2.5-meter connection cable. This should be laid in a plastic pipe designed for electrical material (not included). For supplementary kits, both cold cables should be pulled up and connected in parallel at the thermostat.
3. Place the flexible conduit and pipe alongside each other in a recess in the wall. Make a groove in the floor halfway between where two cable loops will lie. Position the end of the flexible conduit here. The splice between the heating cable and connection cable must also be placed in a groove so it does not protrude from the filler. Do not install in the wall or in the pipe.
Installation Steps
Prepare the Substrate:
- Ensure the floor is firm, does not sag, and is free from dirt and old floor covering. Prime the floor surface with Ebeco Primer + and let it dry.
- Draw on the floor how the mats are to be positioned.
Mounting:
- Perform the first insulation and resistance measurement of the cable. Fill in the test report or use Garantera on your smartphone.
- Start fixing the Thermoflex in a corner. If the cold cable is not long enough to reach the connection point/thermostat, cut the matting into sections and install the cable along the wall. The cable splice should be inset in the floor.
- Remove the protective foil from the mat and align it. Roll out and bond the mat to the floor, pressing it firmly.
- Roll out the matting to the opposite wall. Cut the mesh without damaging the cable. Roll the matting back. Ensure cables are not closer than 5 cm when cutting the mesh.
- Do not lay the matting under fixed fittings like toilet pans. Toilet pans can be fitted with silicone instead of screws. Cut and release mesh sections as needed to navigate around fittings.
- Press the matting down firmly with hands or feet for proper adhesion, especially on rough surfaces like concrete. Use soft-soled shoes or go barefoot to protect the cable. If not applying filler immediately, press the matting down again before filling. For improved adhesion, re-prime the floor with undiluted primer. Mesh can also be stapled to plasterboards.
- Perform other insulation and resistance measurements and document cable location with a photo.
- Cover the floor with suitable floor filler, ensuring the cable is under the sealing layer in wet rooms.
- If possible, after screeding or flooring installation, perform a third insulation and resistance measurement. Fill in the test report or use Garantera.
Wait four weeks after installation before switching on the heating. Increase heat gradually.
Energy Saving Tips!
Ebeco Thermo Board is an insulation board designed for Thermoflex Kit 500/200 under tile and natural stone floors. Its properties make the underfloor heating system extremely fast-acting. Combined with the thermostat's energy-saving program, it creates an energy-saving system. Thermo Board can be used in both wet and dry areas and replaces plasterboard in the floor construction.
Technical Specifications
Detailed specifications for various Thermoflex models are provided below. These include power output, area coverage, and resistance values.
Thermoflex Kit 500 (160 W/m²) | Power | Area | Nominell heat output | Max continous heat output | Resistance* |
---|---|---|---|---|---|
89 610 40 | 165 W | 1.0 m² | 0.165 kW | 0.165 kW | 325 Ω |
89 610 41 | 220 W | 1.4 m² | 0.22 kW | 0.22 kW | 238 Ω |
89 610 42 | 275 W | 1.7 m² | 0.275 kW | 0.275 kW | 194 Ω |
89 610 43 | 365 W | 2.2 m² | 0.365 kW | 0.365 kW | 146 Ω |
89 610 44 | 430 W | 2.7 m² | 0.43 kW | 0.43 kW | 123 Ω |
89 610 45 | 510 W | 3.2 m² | 0.51 kW | 0.51 kW | 104 Ω |
89 610 46 | 580 W | 3.6 m² | 0.58 kW | 0.58 kW | 91 Ω |
89 610 47 | 690 W | 4.4 m² | 0.69 kW | 0.69 kW | 77 Ω |
89 610 48 | 870 W | 5.4 m² | 0.87 kW | 0.87 kW | 61 Ω |
89 610 49 | 1030 W | 6.5 m² | 1.03 kW | 1.03 kW | 52 Ω |
89 610 50 | 1270 W | 7.9 m² | 1.27 kW | 1.27 kW | 42 Ω |
89 610 51 | 1480 W | 9.3 m² | 1.48 kW | 1.48 kW | 36 Ω |
89 610 52 | 1840 W | 11.5 m² | 1.84 kW | 1.84 kW | 29 Ω |
89 610 53 | 2230 W | 13.9 m² | 2.23 kW | 2.23 kW | 24 Ω |
Supplementary set without thermostat (89 610 54) | 1840 W | 11.5 m² | 1.84 kW | 1.84 kW | 29 Ω |
*Tolerance -5% to +10%
Thermoflex Kit 500 | Thermoflex Kit 200 | Thermoflex 120 | Power | Area | Nominell heat output | Max. continous heat output | Resistance* |
---|---|---|---|---|---|---|---|
89 611 00 | 89 602 30 | 89 605 79 | 150 W | 1.25 m² | 0.15 kW | 0.15 kW | 353 Ω |
89 611 01 | 89 602 32 | 89 605 80 | 200 W | 1.7 m² | 0.2 kW | 0.2 kW | 265 Ω |
89 611 02 | 89 602 34 | 89 605 82 | 250 W | 2.1 m² | 0.25 kW | 0.25 kW | 212 Ω |
89 611 03 | 89 602 36 | 89 605 84 | 340 W | 2.7 m² | 0.34 kW | 0.34 kW | 156 Ω |
89 611 04 | 89 602 38 | 89 605 85 | 410 W | 3.4 m² | 0.41 kW | 0.41 kW | 129 Ω |
89 611 05 | 89 602 40 | 89 605 86 | 480 W | 3.9 m² | 0.48 kW | 0.48 kW | 110 Ω |
89 611 06 | 89 602 42 | 89 605 88 | 530 W | 4.4 m² | 0.53 kW | 0.53 kW | 100 Ω |
89 611 07 | 89 602 44 | 89 605 90 | 640 W | 5.4 m² | 0.64 kW | 0.64 kW | 83 Ω |
89 611 08 | 89 602 46 | 89 605 92 | 780 W | 6.6 m² | 0.78 kW | 0.78 kW | 68 Ω |
89 611 09 | 89 602 48 | 89 605 94 | 940 W | 7.9 m² | 0.94 kW | 0.94 kW | 56 Ω |
89 611 10 | 89 602 49 | 89 605 95 | 1170 W | 9.6 m² | 1.17 kW | 1.17 kW | 45 Ω |
89 611 11 | 89 602 50 | 89 605 96 | 1380 W | 11.5 m² | 1.38 kW | 1.38 kW | 38 Ω |
89 611 12 | 89 602 52 | 89 605 98 | 1700 W | 14.0 m² | 1.7 kW | 1.7 kW | 31 Ω |
Supplementary set without thermostat (89 611 13) | 89 611 13 | 89 605 96 | 1380 W | 11.5 m² | 1.38 kW | 1.38 kW | 38 Ω |
*Tolerance -5% to +10%
60 W/m² | Thermoflex 60 | Power | Area | Resistance* |
---|---|---|---|---|
89 610 00 | 80 W | 1.3 m² | 661.3 Ω | |
89 610 01 | 125 W | 2.1 m² | 423.2 Ω | |
89 610 02 | 170 W | 2.8 m² | 311.2 Ω | |
89 610 03 | 215 W | 3.6 m² | 246 Ω | |
89 610 04 | 265 W | 4.4 m² | 199.6 Ω | |
89 610 05 | 325 W | 5.4 m² | 162.8 Ω | |
89 610 06 | 395 W | 6.6 m² | 133.9 Ω |
45 W/m² | Thermoflex 45 | Power | Area | Resistance* |
---|---|---|---|---|
89 602 01 | 60 W | 1.3 m² | 881 Ω | |
89 602 03 | 95 W | 2.1 m² | 556.8 Ω | |
89 602 07 | 130 W | 2.8 m² | 406.9 Ω | |
89 602 09 | 160 W | 3.6 m² | 330.6 Ω | |
89 602 11 | 205 W | 4.4 m² | 258 Ω | |
89 602 13 | 245 W | 5.4 m² | 215.9 Ω | |
89 602 15 | 300 W | 6.6 m² | 176.3 Ω | |
89 602 54 | 335 W | 7.7 m² | 157.9 Ω | |
89 602 56 | 400 W | 9.2 m² | 132.3 Ω |
*Tolerance -5% to +10%
Test Report & Documentation
The Test Report section provides fields for recording resistance and insulation values before laying, after fixing, and after covering the floor. It also includes product selection and installation space details.
Garantera Service: Ebeco's digital service, Garantera, simplifies the documentation of heating cable installations. It allows authorized installers to document measurement data, save installation photos, and create a digital guarantee certificate. Using Garantera can extend the material defect guarantee to 25 years, provided the installation is done correctly with an applicable control system by an authorized electrician.
The installation can be documented with photos/drawings.
Warranty Terms
Ebeco AB provides a 12-year guarantee for material faults on heating cables/foils and supplied accessories/insulation boards. A 5-year product guarantee is provided for the thermostat.
Conditions for Guarantee:
- Installation must be performed by an authorized electrician according to applicable regulations and Ebeco's installation instructions.
- One of the following must be met:
- A) Installation is performed using and documented in Ebeco's Garantera service.
- B) The guarantee certificate and test report are fully completed, signed by the electrician, and accompanied by material specifications or an invoice. Photos or a detailed drawing of the installation must also be provided.
Exclusions: The guarantee does not apply to installations by non-authorized electricians, modifications/repairs by non-authorized personnel, use of improper materials or floor constructions, incorrect installation, or damage caused by vandalism, fire, lightning, water, negligence, abnormal use, or accidents.
Making a Claim: Ebeco AB must be notified before any action is taken. The guarantee certificate, invoice, and signed test report must be presented.
Extended Guarantee: The warranty period can be extended to 25 years for material defects by using the Garantera service.
Contact Information
EBECO AB
Lärjeågatan 11
SE-415 02 Göteborg, SWEDEN
Phone: +46 31 707 75 50
Website: ebeco.com