- 1. Object and Scope of Application
- 2. Intended Use and Users
- 3. Safety Precautions
- 4. Operation
- 5. Maintenance
- 6. Getting Started with Airofit PRO 2.0
- 7. Warning
- 8. Troubleshooting
- 9. Technical Specifications
- 10. Airofit Limited Warranty
1. Object and Scope of Application
This user manual describes the function and intended use of the Airofit PRO 2.0.
2. Intended Use and Users
The Airofit PRO 2.0 respiratory trainer is intended for training the respiratory system muscles. This product is not intended to diagnose, treat, cure, or prevent any disease.
Intended users are:
- The user of the Airoft PRO 2.0
- Persons responsible for training the user of the Airoft PRO 2.0
The Airofit PRO 2.0 is used with the Airofit application, which works on smartphones - Android or iOS.
2.1 Manufacturer's Responsibility
Airoft A/S is solely responsible for the safety, reliability, and performance of the equipment, provided that the Airoft PRO 2.0 is used in accordance with these instructions.
3. Safety Precautions
3.1 Health Considerations when using Airofit PRO 2.0
To avoid damaging your Airofit PRO 2.0 or injuring yourself, please read the following precautions carefully before each use of the Airofit system.
- To prevent the transmission of infections, we recommend not sharing your Airofit PRO 2.0 with other users, including family members. Your Airofit PRO 2.0 is configured to record personalized data for a single user.
- Airofit PRO 2.0 is manufactured in a clean environment. However, Airoft PRO 2.0 has not been sterilized. We recommend cleaning the respiratory trainer before first use.
- Do not use Airofit PRO 2.0 during other activities (running, cycling, rowing, driving, etc.).
- Do not use Airofit PRO 2.0 for more than 60 minutes per day.
- Respiratory training may cause dizziness. It is recommended to remain seated after training and breathe normally for at least 1 to 2 minutes before engaging in other activities.
- Airofit PRO 2.0 is recommended for ages 12 and up. For users under 15 years old, it is recommended to use Airofit under adult supervision.
- Stop exercising immediately if you feel any physical discomfort.
- If you experience dizziness or lightheadedness during exercise 3 with Airofit PRO 2.0, stop training and check if the inspiratory and expiratory resistance wheel settings are correct.
- Do not use Airofit PRO 2.0 if you have a cold, sinusitis, or respiratory tract infection until symptoms completely disappear.
- If you suffer from medical conditions related to your respiratory system, heart, or blood pressure, consult your doctor before using Airofit.
- Do not use Airofit to inhale any substance.
3.2 Contraindications
To avoid damaging your Airofit PRO 2.0 or injuring yourself, please read the following precautions carefully before each use of the Airofit system. Please be cautious in the following situations:
- History of spontaneous pneumothorax (collapsed lung), i.e., not related to traumatic injury.
- Traumatic pneumothorax not fully healed.
- Perforated eardrum that has not yet completely healed, or other eardrum conditions.
- Unstable asthmatic patients with abnormally low perception of dyspnea.
3.3 General Safety Instructions
- Use the Airofit PRO 2.0 respiratory trainer only with the Airofit mobile application and selected sessions and programs. Set the resistance to the recommended settings.
- Do not drop the Airofit PRO 2.0. A fall can lead to malfunction or degraded performance. Check that the inhalation/exhalation ports on the sides of the Airofit PRO 2.0 are not obstructed during training.
- Do not immerse the E-Unit or expose it to water jets or any other liquid. For cleaning instructions, refer to the Maintenance section.
- Do not use scouring pads, abrasive cleaning products, or aggressive liquids such as gasoline or acetone to clean the device. Do not use a dishwasher or autoclave to clean the Airofit PRO 2.0 respiratory trainer. For cleaning instructions, refer to the Maintenance section.
- Ensure your Airofit PRO 2.0 is always clean and in good working order. Always check that your device is dry before storing it. We recommend storing your Airofit PRO 2.0 in a suitable, clean, and hygienic place.
- Only use the magnetic charging cable provided with a CE-certified USB charger (see Technical Specifications).
- If you own multiple Airofit PRO 2.0 devices, do not swap E-Units. Each E-Unit is calibrated to the device. Replacing them would lead to measurement inconsistencies.
4. Operation
The Airofit PRO 2.0 pack consists of:
- Airofit PRO 2.0 Breathing Trainer
- Airofit PRO 2.0 Respiratory Trainer
- Magnetic charging cable
- Airofit PRO 2.0 Quick Guide (in English)
4.1 Description of the Airofit PRO System
The Airofit PRO 2.0 system consists of the Airofit PRO 2.0 respiratory trainer and the Airofit mobile application. The respiratory trainer opposes resistance to your inspiratory and expiratory breathing, while the application guides you through your respiratory training and monitors your performance over time.
4.2 Discover the Airofit PRO 2.0
A Power button
B Removable E-Unit
C Inspiratory resistance wheel
D Expiratory resistance wheel
E Trainer
F Removable mouthpiece
4.2.1 Power Button
To turn on the Airofit PRO 2.0, press the power button. It will blink green to indicate that the device is on – at this point, you can pair it with the mobile application. To turn off the device, press the power button again.
4.2.2 Removable Mouthpiece
The mouthpiece is made of a softer material than the rest of the Airofit PRO 2.0 respiratory trainer to provide total comfort during exercise. To use it, slightly bend the ends of the mouthpiece and then place it in your mouth.
4.2.3 Removable E-Unit
The E-Unit contains electronic components. Do not immerse the E-Unit or expose it to water jets or any other liquid. To clean or charge your Airofit PRO 2.0 respiratory trainer, press firmly on the handles and remove the E-Unit from the rest of the trainer.
4.2.4 Training Unit
The term "Training Unit" is used to refer to the Airofit PRO 2.0 once the E-Unit and mouthpiece are removed.
4.2.5 Charging
The charging port is located inside the E-Unit. Connect the magnetic cable to the charger. When the indicator light blinks green, the cable is correctly connected and your E-Unit is charging. Once the E-Unit is fully charged, the green light remains steady.
4.3 Correct Use of Airofit
You should be relaxed and seated upright when using the Airofit PRO 2.0. Keep your head straight, as lowering it may lead to increased salivation. Do not hold the Airofit PRO 2.0 trainer with your hand during training, except in cases of absolute necessity. If you must do so, hold it with your hand at the E-Unit level and ensure that the openings near the resistance wheels are not obstructed.
Place the device in your mouth so that your lips cover the outer protection of the mouthpiece to create a complete seal. The mouthpiece locking device should be held firmly between your teeth.
At the beginning of the exercise, the respiratory trainer requires a short calibration (zeroing) of the pressure measurement. Do not breathe into the device during this process. Wait for instructions to begin the breathing exercise.
The Airofit PRO 2.0 respiratory trainer should not be used during physical activity. Respiratory training during physical exercise reduces oxygenation of the locomotor muscles.
5. Maintenance
Please follow the guidelines below to ensure your Airofit PRO 2.0 respiratory trainer remains hygienic and in good working order.
Airofit PRO 2.0 Respiratory Trainer. (Youtube: Airofit PRO - Care and Maintenance)
5.1 Daily Maintenance
As the device is exposed to saliva during use, it is important to clean it frequently.
We recommend rinsing the training unit and mouthpiece in hot water (below 60°C) after each use. After rinsing, shake and blow into the training unit and mouthpiece to remove excess water. Ensure the device is completely dry before reassembling it. Do not immerse the E-Unit or expose it to water jets or any other liquid.
5.2 Weekly Maintenance
Once a week, separate the training unit and mouthpiece for more thorough cleaning. Use a drop of dish soap to carefully wash the training unit and mouthpiece. After washing, rinse the training unit under running water. After cleaning, shake and blow into the training unit and mouthpiece to remove excess water. Ensure the device is completely dry before reassembling it.
5.3 Monthly Maintenance
Fully charge your E-Unit at least once a month, even if you are not using it, to prevent the battery from discharging completely.
6. Getting Started with Airofit PRO 2.0
6.1 Before First Use
Before starting your training, it is necessary to fully charge your E-Unit until the indicator light turns solid green. This initial charge may take up to 24 hours. While the E-Unit is charging, rinse the training unit and mouthpiece with warm water, wipe them with a clean towel, and let them air dry. When the E-Unit is fully charged and the training unit and mouthpiece are completely dry, you can reassemble the respiratory trainer. The E-Unit contains electronic components; do not immerse the E-Unit or expose it to water jets or any other liquid.
6.1.1 Registration Procedure
The Airofit application will guide you through the first steps of your Airofit journey.
6.1.2 Pulmonary Test
As indicated in the Airofit application, you must start by performing a pulmonary test to assess your respiratory condition. A notification from the application will appear when you need to perform the pulmonary test.
The pulmonary test allows you to record:
- Accessible lung capacity, your active lung volume
- Inspiratory strength, your Maximum Inspiratory Pressure (MIP)
- Expiratory strength, your Maximum Expiratory Pressure (MEP)
These measurements are evaluated considering your sex, age, and height (as defined in your profile). Percentages (from 0 to 200%) indicate how you compare to other users with the same demographic characteristics.
6.2 Starting Training
In the Airofit application, you will find training recommendations based on the objective selected in the application. Prepare your device by adjusting the resistance levels and follow the application's recommendations to start training. When the exercise is finished, a results screen will appear in the application, allowing you to view a summary of your training.
Understanding Training Levels
- Beginner: Low pressure with short breathing cycles
- Intermediate: Medium pressure with medium breathing cycles
- Advanced: High pressure with long breathing cycles
Understanding Training Durations
Training duration varies between 1 and 10 minutes. We strongly recommend taking a break every 3 minutes of training.
6.3 Training History
The application memorizes your training history to allow you to access your pulmonary test results and your training sessions at any time.
6.4 Settings
You can update your profile in the settings. Your account is secured by a password that can be reset. You can enable/disable background music and guidance sounds. If you have questions about training, you can find answers by clicking the FAQ button. If you detect a problem in the application, you can also report it. The application contains a Privacy Policy and General Terms and Conditions (requiring an internet connection) that you have accepted when creating your account.
6.5 Fundamentals of Respiratory Performance
Term | Description |
---|---|
cmH2O | Pressure exerted by a 1 cm high column of water. 1 cmH2O = 0.980665 hPa (or mbar) |
Accessible lung capacity | The total amount of usable lung capacity reserves you can access |
Lung capacity conformity | Conformity in percentage is evaluated based on sex, age, and height |
Respiratory pressure | Maximum inspiratory pressure (MIP): Normal range: 20 - 170 cmH2O Average: 75 ±25 cmH2O Maximum expiratory pressure (MEP): Normal range: 20 - 230 cmH2O Average: 95 ±35 cmH2O |
Airflow resistance | Resistance to airflow during breathing |
Breathing conformity | Conformity in percentage is evaluated based on sex, age, and height |
Exercise level | Beginner Intermediate Advanced |
7. Warning
List of warning notifications:
Term | Description |
---|---|
Low battery (20%) | Your Airofit device battery is low. Please charge it as soon as possible. |
Low battery (5%) | Your Airofit device battery is critically low and may shut down unexpectedly. Please charge it as soon as possible. |
Too many variables | Cannot calibrate the device correctly. Ensure you are not breathing into the device and that it is not cold (warm it in your hand before trying again). |
8. Troubleshooting
General troubleshooting tips can be found on our website: https://www.airoft.com/faq
9. Technical Specifications
9.1 Airofit PRO Respiratory Trainer
Description | Notes |
---|---|
Air Resistance | |
Inhalation air resistance | A-F: 10-250 cmH2O at (1 litre/sec) |
Exhalation air resistance | 1-6: 10-200 cmH2O at (1 litre/sec) |
Monitoring | |
Accessible lung capacity | 0.5 - 10.0 liters |
Respiratory pressure | 10 - 230 cmH2O |
Lung capacity conformity | 0 to 200%: Low: < 2.5 liters Medium: 2.5 – 4.5 liters High: > 4.5 liters |
MIP/MEP conformity | 0 to 200%: Low: < 70% Medium: 70 - 140% High: > 140 % |
Breathing compliance | 0 to 100%: Acceptable: 20-40% Fair: > 40-60 % Good: > 60-80% Perfect: > 80% |
Exercise level | 0 to 100% of MIP/MEP Beginner: < 50% Intermediate: 70% Expert: > 90 % |
Exercise settings | Air resistance settings Beginner: (D4, C3, B2) Intermediate: (E5, D4, C3) Expert: (F6, E5, D4) |
Material | |
Mouthpiece | TPE |
Housing | ABS |
Battery | |
Rechargeable | 0.5 - 10.0 liters |
Capacity | 10 - 230 cmH2O |
Charger | 5V, min 100mA |
Charging time | 8 hours |
Charger plug | Magnetic connector |
Communication | |
Bluetooth | BLE version 5.1 |
Dimensions | |
Size | 70mm x 77mm x 33mm |
Weight | 45g |
Smartphone App | |
iOS version | 12 or later |
Android version | 11 or later |
9.2 Environment
Description | Notes |
---|---|
Operating Conditions | |
Internal temperature | 15 °C to 35 °C |
External temperature | 00 °C to 45 °C |
Relative humidity | 10 % to 90 % HR |
Pressure | 960 hPa to 1 060 hPa |
IP Classification | IP64 |
Storage and Transport Conditions | |
Temperature | -25 °C to 50 °C |
Relative humidity | 10 % to 90 % HR |
Pressure | 700 hPa to 1 060 hPa |
Protection against electric shock | |
Electrical safety | Type B |
Leakage current | < 0.5mA |
EMC | IEC 60601-1-2 |
9.3 Directives and Standards
The Airofit PRO 2.0 respiratory trainer complies with the Medical Device Directive - MDD 2007/47/EC. The Airofit PRO 2.0 respiratory trainer complies with Class I medical devices.
The Airofit PRO 2.0 respiratory trainer complies with European directive 19 on the protection of personal data 2016/680/EU.
The main standards applied are:
Standard | Title | Date |
---|---|---|
IEC 60601-1 (ed. 3.1) | Medical electrical equipment. General requirements for basic safety and essential performance | 2012 |
IEC 60601-1-2 | Medical electrical equipment. Electromagnetic compatibility requirements and tests | 2014 |
ISO 13485 | Medical devices. Quality management systems – Requirements for regulatory purposes | 2016 |
ROHS (2011/65/EU) | Limitation of the use of certain hazardous substances in electrical and electronic equipment | 2011 |
REACH (EC 1907/2006) | Registration, evaluation, and authorization of chemical substances | 2006 |
WEEE | Directive 2012/19/EU | 2012 |
9.4 Radio Equipment Conformity
The Airoft system complies with the Radio Equipment Directive (RED) - 2014/53/EU. The device complies with Part 15 of the FCC rules. FCC ID: 2ATQX-AF003
Operation is subject to the following two conditions:
- This device must not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and declared to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the distance between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The license-exempt transmitter/receiver contained in this device complies with Industry Canada's license-exempt RSS standard(s).
IC: 25191-AF003
Operation is permitted under the following two conditions:
- The device must not produce interference.
- The device must accept any radio interference, even if the interference may compromise its operation.
The product has been tested in accordance with the provisions of Article 38-24, Paragraph 1 of the Japanese Radio Law, Article 2-1-19 (radio equipment), low-power wideband data communication system, 2.4 GHz band 2,400~2,483.5 MHz. Giteki certification number: R020-220095
10. Airofit Limited Warranty
Airoft Sport A/S warrants that this product is free from material or manufacturing defects for a period of twenty-four (24) months from the date of purchase, provided the product is used in a domestic setting and in accordance with this user manual. This limited warranty is in addition to the rights you may have under applicable consumer protection laws. This limited warranty does not cover failures due to abuse, accidental damage, or if repairs or attempted repairs have been made by a third party other than Airoft Sport A/S. A defective product meeting the warranty conditions stated herein will be replaced or repaired free of charge. If the product is defective, please return the product to the retailer where it was purchased (provided the store is a participating retailer). Returns must be made within the warranty period. Proof of purchase is required.
Please inquire with the retailer for their specific return or exchange conditions. Under this warranty, you benefit from specific legal rights. You may also benefit from other rights that vary depending on the country or state.
Please consult the retailer for their specific return or exchange policy. This warranty offers you specific rights and you may benefit from other specific rights depending on the country. If you have questions, please contact Airoft customer service. This product is not intended for commercial use. Therefore, any commercial use of this product will void this warranty. All other warranties, express or implied, are hereby disclaimed.
DISCLAIMER
AIROFIT SERVICES ARE INTENDED FOR WELL-BEING MANAGEMENT AND PHYSICAL TRAINING. THESE SERVICES, AS WELL AS ANY CONTENT OR RESULTS DISPLAYED, FROM AIROFIT OR THIRD PARTIES, DO NOT CONSTITUTE MEDICAL ADVICE AND SHOULD NOT BE SUBSTITUTED FOR PROFESSIONAL MEDICAL ADVICE, DIAGNOSIS, OR TREATMENT. DO NOT IGNORE OR DELAY SEEKING MEDICAL ADVICE BASED ON ANYTHING CONTAINED IN THE SERVICES. NO DOCTOR-PATIENT RELATIONSHIP IS CREATED BY THE USE OF THE SERVICES OR COMMUNICATION VIA THE INTERNET, EMAIL, OR OTHER MEANS WITH AIROFIT. THE SERVICES AND THEIR CONTENT ARE PROVIDED FOR GENERAL INFORMATION PURPOSES ONLY, AND ARE NOT INTENDED TO DIAGNOSE, TREAT, OR PREVENT ANY PATHOLOGICAL CONDITION. ALWAYS CONSULT A QUALIFIED HEALTH PROFESSIONAL BEFORE STARTING A NEW REGIMEN, EXERCISE, OR TRAINING PROGRAM. YOU ACKNOWLEDGE THAT PHYSICAL ACTIVITIES INVOLVE RISKS AND YOU ASSUME ALL RISKS ASSOCIATED WITH THESE ACTIVITIES.
Copyright © 2022 by Airoft A/S, Denmark
All rights reserved. No part of this publication may be reproduced, distributed, or transmitted in any form or by any means, including photocopying, recording, or other electronic or mechanical methods, without the prior written permission of Airoft A/S.
Airofit A/S
Titangade 11
Copenhagen N, 2200
Denmark
Mail: info@airofit.com
Related Documents
![]() |
Airofit Pro 2.0 User Manual User manual for the Airofit Pro 2.0 respiratory training device, covering setup, usage, maintenance, and troubleshooting. |
![]() |
Airofit Pro 2.0 User Manual - Optimize Your Breathing Comprehensive user manual for the Airofit Pro 2.0 breathing trainer. Learn about setup, operation, maintenance, technical specifications, and troubleshooting for this advanced respiratory training device. |
![]() |
Airofit Pro 2.0 User Manual This user manual provides comprehensive instructions for the Airofit Pro 2.0, covering its purpose, usage, safety precautions, maintenance, and technical specifications. Learn how to use the Airofit Pro 2.0 for respiratory muscle training and improve your lung capacity. |
![]() |
Airofit PRO User Manual: Respiratory Training Device Guide Comprehensive user manual for the Airofit PRO, a smart respiratory training device. Learn about its features, intended use, safety guidelines, operation, maintenance, technical specifications, and warranty. This guide helps users optimize their breathing exercises for improved respiratory health and performance. |
![]() |
Airofit Essential User Manual: Breathing Training Guide Comprehensive user manual for the Airofit Essential breathing trainer, covering setup, operation, maintenance, troubleshooting, and technical specifications. Learn how to optimize your respiratory performance with Airofit. |
![]() |
Airofit Active User Manual - Improve Your Breathing Comprehensive user manual for the Airofit Active breathing trainer. Learn how to set up, use, and maintain your device for optimal respiratory training. Includes safety information, troubleshooting, and warranty details. |
![]() |
Airofit Active User Manual - Improve Breathing and Fitness Comprehensive user manual for the Airofit Active breathing trainer. Learn how to set up, use, maintain, and troubleshoot your device for optimal respiratory training and fitness. |
![]() |
Airofit Pro 2.0 User Manual This user manual provides comprehensive instructions for the Airofit Pro 2.0 breathing trainer, covering its purpose, intended use, safety precautions, operation, maintenance, and troubleshooting. It also includes technical specifications and warranty information. |