Rasonic Window Type Air Conditioner

USER MANUAL

Model: RC-XG7, RC-XG9, RC-XG12, RC-XG18

Thank you for purchasing Rasonic window type air conditioner. Please read the user manual carefully before installation and keep it for your reference.

Explanation of Symbols

DANGER
Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
WARNING
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
NOTICE
Indicates important but not hazard-related information, used to indicate risk of property damage.
!
Indicates a hazard that would be assigned a signal word WARNING or CAUTION.

Exception Clauses

Rasonic will bear no responsibilities when personal injury or property loss is caused by the following reasons:

If it needs to install, move or maintain the air conditioner, please contact dealer or local service center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed unit. Otherwise, it may cause serious damage or personal injury or death.

When refrigerant leaks or requires discharge during installation, maintenance, or disassembly, it should be handled by certified professionals or otherwise in compliance with local laws and regulations.

The Refrigerant

WARNING:

According to EN60335-1:

Specialist's Manual

Precautions

WARNING

Install the devices for short-circuit protection and electrical leakage protection when installing the air conditioner. According to the local safety regulations, use qualified power supply circuit and circuit break.

Working temperature range

Operating Temperature Range
Indoor side DB/WB(°C) Outdoor side DB/WB(°C)
Maximum cooling 32/23 43/-

The operating temperature range (outdoor temperature) for cooling only unit is 18°C~43°C.

Function

Introduction

Window type room air conditioners can regulate the room temperature and dry the room. It is convenient for your work, study and life. It can be widely used in residence, shop, hotel, office, library and laboratory, and so on.

Cooling in summer

In hot summer, Air conditioner can cool down the room air by transferring heat out.

Dehumidifying in rainy or humid season

Without reducing the room temp., air conditioner can dehumidify and make the room air dry and comfortable.

Exchange fresh air

Adjust ventilation lever to keep the fresh air in the room.

Operating Condition

COOL mode operation

Outdoor temperature should be in range of 18°C to 43°C, otherwise it is possible for air conditioner to breakdown. Room humidity should be lower than 90%. Otherwise, it is possible for air conditioner to dew at air conditioner surface and even drop water after running for so much time. But this is normal.

DRY mode operation

Outdoor temperature should be in range of 18°C to 43°C, otherwise it is possible for air conditioner to breakdown.

Power requirement

Rated Input: 220V~50Hz

Earth wire

To ensure the reliable earthing, please do not connect earth wire to the following places:

Water pipe [X]

Installation

Installation precaution

Window type air conditioner is so valuable and the improper installation of it will cause a lot of damage! Please associate the qualified technician to install the unit and don't install it by yourself. Otherwise, we are not responsible for the damage.

Location

How to install

The distance between the air conditioner and the around obstacles should meet the requirement as below: over 300mm(upper side), over 500mm (left side), over 500mm (right side), over 1500mm (front side) and over 500mm (rear side).

Diagrams:

Installation procedure

  1. Remove the sticker from the front panel.
  2. Put the unit into the installation hole.
    • When installing the unit, it should be slanted down to the back to avoid the enlargement of noise or vibration. (Slant between 6-10mm.)
    • The installation place should be strong enough to avoid the enlargement of noise or vibration.
  3. Fill up sews in the cabinet with sponge or foam.

Installation assistance

Drain water (Method 1)

To get the maximum cooling efficiency, the air conditioner is designed to splash the condensate on the condenser coil. If the splashing sound annoys you, you can provide an outside drain by using the following procedure, which may however cause a small loss of performance.

  1. There is a drainage outlet at the back of the unit.
  2. Remove cover from the drainage outlet, and then connect drainage joint to it with screw.
  3. Connect the drain hose to the outlet.

Note: Drain hose or tubing can be purchased locally to satisfy your particular needs.

Drain water (Method 2)

To get the maximum cooling efficiency, the air conditioner is designed to splash the condensation water on the condenser coil. To the cooling only unit, If the splashing sound annoys you, you can provide an outside drain by using the following procedure, which may however cause a small loss of performance.

  1. Slide out the chassis from the cabinet.
  2. Remove the rubber plug from the body base plate.
  3. Install the drain pan to the corner of the cabinet with 2 screws.
  4. Connect the drain hose to the outlet on the drain pan bottom.
  5. Slide the chassis into its original place in the cabinet.

Notes for installation

Remove

Before removing air conditioner to the other place, you should contact the seller firstly. Then it must be done under the direction of the professional technician. In addition, the charge of this must be paid.

Noise

Electric wiring

Part identification

Panel outlook picture, just for reference, please take the real unit as standard.

Air direction adjustment

Vertical airflow direction vane

(Airflow direction adjustment up and down).

The vertical airflow direction vane is controlled by positioning the vane to discharge the air upwards, downwards or straight out.

Remote control operation procedure

Buttons on remote controller

Introduction for icons on display screen

Introduction for buttons on remote controller

Note:

1 ON/OFF button

Press this button to turn unit on/off.

2 MODE button

Pressing this button once can select your required mode circularly as below (the corresponding icon "<0xE2><0x96><0xB3>" will be lit up after the mode is selected): AUTO, COOL, DRY, FAN, HEAT(not applicable for cooling only model)

3 +/- button

Introduction for buttons on remote controller

4 FAN button

Pressing this button can select fan speed circularly as: AUTO, SPEED 1 ( ), SPEED 2 ( ), SPEED 3 ( ), SPEED 4 ( ) (unavailable in this air conditioner. Speed 4 is the same with speed 3.).

Note:

5 SWING button

Press this button to turn on left & right air swing.

6 SLEEP button

Under Cool and Dry mode, press this button to turn on Sleep function. Press this button to cancel Sleep function. Under Fan and Auto mode, this function is unavailable.

7 TIMER button

Introduction for buttons on remote controller

Note:

Function introduction for combination buttons

Child lock function

Press "+" and "-" buttons simultaneously can turn on or turn off child lock function. When child lock function is started up, LOCK indicator on remote controller is ON. If you operate the remote controller, remote controller won't send signal.

Temperature display switchover function

Under OFF status, press "-" button and "MODE” button simultaneously can switch between °C and °F.

Operation guide

  1. After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner.
  2. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT(not applicable for cooling only model).
  3. Press "+" or "-" button to set your required temperature. (Temperature can't be adjusted under auto mode).
  4. Press "FAN" button to set your required fan speed: auto, low, medium and high speed.

Replacement of batteries in remote controller

  1. Press the mark "<0xE2><0x96><0xB3>" on back cover of batteries box cover for remote controller with fingers as shown in the fig, and then remove the batteries box cover along the arrow direction.
  2. Replace with two #7 (AAA 1.5V) dry batteries. Make sure positions for "+" pole and "-" pole are correct.
  3. Reinstall batteries box cover.

NOTICE:

Control panel

Note: If remote controller is lost, open the surface panel and operate manually.

VENTILATION LEVER

Operation Tips

Operation for comfort and economy

CAUTION

Operations for safety and health

  1. The plug must be accessible after the appliance is positioned.
  2. Do not use this appliance in the laundry.
  3. If the power cord is damaged, it must be replaced by the manufacturer or its service agent in avoidance of hazard.

Always wait at least 3 minutes before switching the air conditioner on again after you have switched it off.

Please notice that the unit is filled with flammable gas R32. Inappropriate treatment of the unit involves the risk of severe damages of people and material. Details to this refrigerant are found in chapter "refrigerant". The appliance is using mildly flammable refrigerant R32 and tested to comply with 60335-2-40. There is no minimum room area requirement for the appliance.

Care and maintenance

Always turn off the air conditioner and main power supply before cleaning to ensure safety.

Cleaning unit

  1. Cut power off before cleaning.
  2. Use soft cloth when cleaning cabinet. If the cabinet is very dirty, dip cloth into warm water below 40°C, dry the cloth and then rub off the dirt.
  3. Don't use gas, benzene, etc. chemical solvent for cleaning.
  4. Do not splash water directly into the unit, in which there are micro-computer and circuit plate, they must not be drenched with water.

Air filter

The air filter behind the intake grille should be washed at least once every two weeks or as often as it needs cleaning.

How to clean the air filter:
  1. To remove the air intake grille, grasp the tab on the filter and pull to take out.
  2. Vacuum the filter on the dusty side to remove light dust.
  3. Wash the filter under gently flowing water to wash out accumulated dust and lint.
  4. If the filter is very dirty, use a mild household detergent in the wash water.

Let the filter dry thoroughly before reinstalling it.

Troubleshooting guide

Please check the following items before asking for repair, it saves your time and money.

Fault phenomenon Trouble-shooting
Air conditioner does not operate at all.
  • Is there a power failure?
  • Is the plug out?
  • Is power fuse or switch off?
  • Whether the voltage is too high or too low?
Cool efficiency is not good.
  • Is air inlet or outlet blocked?
  • Is there any other heat source in room?
  • The filters dirty?
  • Is indoor fan speed set at LOW?
  • Maybe the room is too hot when the unit is started.
Foggy air flows out.
  • At COOL mode operation, sometimes there is foggy air flowing out of the unit, this is because the room humid air has been cooling rapidly.
  • The unit is normal while the indoor outlet is sending out some odor, because the inlet air may be mixed with the smell of furniture and smoke.
The air conditioner operation is noisy.
  • For a noise that sounds like water flowing: This is the sound of refrigerant flowing inside the air conditioner unit.
  • For a noise that sounds like a shower: This is the sound of the dehumidifying water being processed inside the air conditioner unit.
It seems that condensation is leaking from air conditioner. Condensation occurs when the airflow from the air conditioner cools the warm room air.
Air conditioner does not operate for about 3 minutes when restart.
  • This is air conditioner protection mechanism.
  • Wait about three minutes and operation will begin.

Safety operation of flammable refrigerant

Qualification requirement for installation and maintenance

  1. All the worker who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant.
  2. It can only be repaired by the method suggested by the equipment's manufacturer.

Installation notes

  1. The air conditioner is not allowed to use in a room that has open flames (such as fire source, working coal gas ware, operating heater).
  2. The appliance is using mildly flammable refrigerant R32 and tested to comply with IEC 60335-2-40. There is no minimum room area requirement for the appliance.
  3. Leak test must be done after installation.

Maintenance notes

  1. Check whether the maintenance area or the room area meet the requirement of the nameplate. It's only allowed to be operated in the rooms that meet the requirement of the nameplate.
  2. Check whether the maintenance area is well-ventilated. The continuous ventilation status should be kept during the operation process.
  3. Check whether there is fire source or potential fire source in the maintenance area.
  4. Check whether the appliance mark is in good condition.
    • Replace the vague or damaged warning mark.

Welding

  1. If you should cut or weld the refrigerant system pipes in the process of maintaining, please follow the steps as below
    • a. Shut down the unit and cut power supply
    • b. eliminate the refrigerant
    • c. vacuuming
    • d. clean it with N2 gas
    • e. cutting or welding
    • f. carry back to the service spot for welding
  2. The refrigerant should be recycled into the specialized storage tank.
  3. Make sure that there in not any naked flame near the outlet of the vacuum pump and it's well-ventilated.

Filling the refrigerant

  1. Use the refrigerant filling appliances specialized for R32. Make sure that different kinds of refrigerant won't contaminate with each other.
  2. The refrigerant tank should be kept upright at the time of filling refrigerant.
  3. Stick the label on the system after filling is finished (or haven't finished).
  4. Don't overfilling.
  5. After filling is finished, please do the leakage detection before test running; another time of leak detection should be done when it's removed.

Safety instructions for transportation and storage

  1. Please use the flammable gas detector to check before unload and open the container.
  2. No fire source and smoking.
  3. According to the local rules and laws.

Special Avowal

  1. The information above has been checked; our company reserves the hermeneutic power to any print errors or misunderstanding on the content.
  2. Any technology improvement will add into new user manual without any prior notices. The product appearance and color refer to the practical air conditioner.
  3. The e-copy of user manual can be sent by e-mail on requested, please call Shun Hing Electric Works & Engineering Co. Ltd. hotline at 2861 2767.

After sale service

Guarantee period state from the date of purchasing to one year. If the product is damaged under proper use, a free repair service is available. Please present the official invoice and the guarantee certificate with the sales point's chop / redemption center's chop for free maintenance. For enquiries, please contact Shun Hing Electric Service Centre Limited hotline at 2406 5666.

Turn off the power and contact Shun Hing Electric Service Centre Ltd. as soon as any of the following events occur.

Contact Information

Rasonic

信興電工工程有限公司

SHUN HING ELECTRIC WORKS & ENGINEERING CO., LTD

OFFICE: 9/F, PENINSULA CENTRE, 67 MODY ROAD, TSIMSHATSUI EAST, KOWLOON, HONG KONG

TEL: (852) 2861 2767 | FAX: (852) 2865 6706

WEBSITE: www.rasonic.hk | EMAIL: shew@shunhinggroup.com

MAINTENANCE AND REPAIR SERVICE

信興電器服務中心有限公司

SHUN HING ELECTRIC SERVICE CENTRE LTD.

OFFICE: 11TH FLOOR, SHUN HING CENTRE, 2 SHING YIU STREET, KWAI CHUNG, NEW TERRITORIES, HONG KONG

TEL: (852) 2406 5666 | FAX: (852) 2408 0316

WEBSITE: www.shesc.com

CONSUMABLES/ ACCESSORIES SALES HOTLINE

TEL: (852) 2406 5666

CUSTOMER SERVICE CENTRES

HONG KONG: 1ST FLOOR, SHUN HING CENTRE, 2 SHING YIU STREET, KWAI CHUNG, NEW TERRITORIES, HONG KONG

TEL: (852) 2406 5439 | FAX: (852) 2408 1389

MACAU: AVENIDA DE VENCESLAU DE MORAIS, NO. 193-199, 5 ANDAR-I, EDF. INDUSTRIAL NAM LENG, MACAU

TEL: (853) 2836 2928 | FAX: (853) 2833 6405

For the latest information of customer service centres, please visit www.shesc.com or call us at our hotline.

Models: RC-XG7, RC-XG7 Window Type Air Conditioner, Window Type Air Conditioner, Type Air Conditioner, Air Conditioner

File Info : application/pdf, 32 Pages, 3.80MB

PDF preview unavailable. Download the PDF instead.

RC-XGxx 說明書 EN

References

doPDF Ver 11.3 Build 201

Related Documents

Preview Rasonic Window Type Air Conditioner User Manual
User manual for Rasonic window type air conditioners, covering installation, operation, maintenance, and troubleshooting. Includes safety precautions and product specifications.
Preview Rasonic Window Type Air Conditioner Operating Instructions
Comprehensive operating instructions for Rasonic Window Type Air Conditioners, covering installation, operation, maintenance, troubleshooting, and safety precautions for models RC-X7HA, RC-X9HA, RC-X12HA, and RC-X18HA.
Preview Rasonic Air Conditioners: Advanced Features, Energy Efficiency, and Model Guide
Explore the Rasonic air conditioner range, featuring nanoe-G air purification, Inverter technology, AEROWINGS airflow, and energy-efficient models. Find specifications and features for cooling and heating solutions.
Preview Rasonic Air Conditioners: Innovative Features and Energy Efficiency
Explore the Rasonic range of inverter air conditioners, featuring nanoe-G air purification, AEROWINGS dual-layer louvers, and energy-saving technology. Find models for cooling and heating with detailed specifications.
Preview Rasonic R410A Window Type Air Conditioner User Manual - Models RC-X7KM, RC-X9KM
This user manual provides comprehensive instructions for operating, installing, and maintaining the Rasonic R410A Window Type Air Conditioner, models RC-X7KM and RC-X9KM. It includes safety precautions, parts identification, operating modes, troubleshooting tips, and specifications.
Preview Rasonic R32 變頻淨冷 窗口式冷氣機 遙控器操作說明書
本說明書提供 Rasonic R32 變頻淨冷 窗口式冷氣機遙控器的全面操作指南,涵蓋按鈕功能、顯示指示、操作方法及處理須知,適用於 RC-S701AC、RC-S901AC、RC-S1201AC 及 RC-S1801AC 型號。
Preview Rasonic RC-HZ180Z/RC-HZ240Z Air Conditioner Operating Instructions
This document provides comprehensive operating instructions and installation guidance for Rasonic RC-HZ180Z and RC-HZ240Z air conditioners. It covers essential safety precautions, detailed installation procedures, various operating modes, maintenance tips, and troubleshooting advice to ensure optimal performance and user safety.
Preview Rasonic Air Conditioner Remote Control Operation Manual - RS-S9KI, RU-S9KI, RS-S12KI, RU-S12KI, RS-S18KI, RU-S18KI
Comprehensive operation manual for the Rasonic R410A Inverter Cooling Split-Type Room Air Conditioner remote control. Covers specifications, functions, basic and advanced operations, and troubleshooting tips for models RS-S9KI, RS-S12KI, RS-S18KI, RU-S9KI, RU-S12KI, RU-S18KI.