Rasonic Window Type Air Conditioner

OPERATING INSTRUCTIONS

Models: RC-X7HA, RC-X9HA, RC-X12HA, RC-X18HA

Thank you for purchasing a Rasonic window type air conditioner. Please read this user manual carefully before installation and keep it for future reference.

CONTENTS

Thank you for choosing this air conditioner. Our design is based on the best efficiency and the lowest noise operation, ensuring a comfortable room environment. Please read this operating manual carefully before operating the unit and keep it for consultation.

Structure mechanism and Installation

  • Precautions

  • Function

  • Operating condition

  • Power requirement

  • Installation

  • Notes for installation

Operation procedure

  • Part identification

  • Remote control operation procedure

  • Introduction for icons on display screen

  • Introduction for buttons on remote controller

  • Remote control panel

  • Operation tips

Care and maintenance

  • Caution

  • Care and maintenance

  • Trouble shooting guide

  • After service

NOTICE

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

The appliance shall be installed in accordance with national wiring regulations. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

Please read this operating manual carefully before operating the unit. The figures in this manual may be different from the material objects; please refer to the material objects for reference.

Explanation of Symbols

  • DANGER: Indicates a hazardous situation that, if not avoided, will result in death or serious injury.

  • WARNING: Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

  • CAUTION: Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.

  • NOTICE: Indicates important but not hazard-related information, used to indicate risk of property damage.

  • !: Indicates a hazard that would be assigned a signal word WARNING or CAUTION.

Precautions

Warning

Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

The air conditioner should be installed in accordance with national wiring regulations. Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock.

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Do not connect air conditioner to multi-purpose socket. Otherwise, it may cause fire hazard.
  • Do install the air switch. If not, it may cause malfunction.
  • Do not spill water on the remote controller; otherwise the remote controller may be broken.
  • Do not spray water on air conditioner. It may cause electric shock or malfunction.
  • Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage.
  • Do not step on air conditioner, or put heavy objects. It may cause damage or personal injury.
  • Do not block air outlet or air inlet. It may cause malfunction.
  • Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
  • Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner.
  • Maintenance must be performed by qualified professionals. Otherwise, it may cause injury or damage.
  • The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
  • Children being supervised not to play with the appliance.

Please install the devices for short-circuit protection and electrical leakage protection when installing the air conditioner. According to the local safety regulations, use qualified power supply circuit and circuit break.

Working temperature range

Operating Temperature RangeIndoor side DB/WB(°C)Outdoor side DB/WB(°C)
Maximum cooling32/2343/-
Maximum heating27/-24/18

The operating temperature range (outdoor temperature) for cooling only unit is 18°C~43°C.

Function

Introduction

Window type room air conditioners can regulate the room temperature and dry the room. It is convenient for your work, study, and life. It can be widely used in residence, shop, hotel, office, library, and laboratory, and so on.

Cooling in summer

In hot summer, the air conditioner can cool down the room air by transferring heat out.

Dehumidifying in rainy or humid season

Without reducing the room temp., the air conditioner can dehumidify and make the room air dry and comfortable.

Exchange fresh air

Open storm door to keep the fresh air in the room.

Operating Condition

Please operate air conditioner in the correct conditions as following.

COOL mode operationDRY mode operation
Outdoor temperature should be in range of 18°C to 43°C, otherwise it is possible for air conditioner to breakdown. Room humidity should be lower than 90%. Otherwise, it is possible for air conditioner to dew at air conditioner surface and even drop water after running for so much time. But this is normal.Outdoor temperature should be in range of 18°C to 43°C, otherwise it is possible for air conditioner to breakdown.

Power requirement

The electric components will be damaged when the voltage is too high. If the voltage is too low, the compressor will vibrate violently to damage the refrigerant system and easily cause the compressor and electric components not work.

The ground must be connected. A special socket must be used. Furthermore, the socket and wiring must conform to the wiring regulations. And the earthing method must be reliable.

In a fixed circuit, there must be an electricity leakage protection switch of enough power capacity and an air switch with enough space.

Earth wire

To ensure the reliable earthing, please do not connect earth wire to the following places:

Water pipe [invalid grounding symbol]

Installation

Installation precaution

Window type conditioner is valuable, and improper installation will cause a lot of damage! Please use a professional technician to install the unit and do not install it yourself. Otherwise, Rasonic is not responsible for such damage.

Location

  • The condensation water must be drained away conveniently.
  • Install air conditioner unit far away from TV set or radio etc. to avoid disturbing video or voice.
  • In salt and coastal areas or places near thermal springs and polluted by sulphurous gas, or other special areas, please contact the seller before use.
  • Avoid a place where is possible for inflammable gas to leak out.
  • Avoid other heat sources or direct sun light.
  • Avoid a place where is easy for children to touch.
  • Do not use the unit in the immediate surroundings of a laundry, a bath, a shower, or a swimming pool.
  • For window type air conditioners with remote control, install in a location where there is strong electromagnetic disturbance; you should contact the seller in advance to avoid malfunction in use.

How to install

  • Choose a location where there are no obstacles surrounding the unit, and the plug is accessible.
  • Prepare the installation hole slightly bigger than the unit size.
  • Choose the installation space according to the following diagram. [Diagram showing top, front, and side views of installation space with clearances: Over 150 mm, Over 500 mm, Less than 220 mm]

Installation procedure

  1. Remove the sticker from the front panel.
  2. Put the unit into the installation hole.
    • When installing the unit, it should be slanted down towards the back to avoid the enlargement of noise or vibration (Slant between 6-10mm). [Diagram showing side view with 6-10mm slant]
    • The installation place should be strong enough to avoid the enlargement of noise or vibration.
  3. Fill up seams in the cabinet with sponge or foam.

Installation assistance

  • Use iron support: The installation hole should be strong enough to support the air conditioner. If it cannot, iron support has to be used outdoors. Iron support should be fixed on the building. [Diagram showing unit mounted with iron support]
  • Use sunshade board: The air conditioner should avoid anything being dropped into it and avoid direct sunshine. If there is no cover on it, contact the seller for installing the sunshade board. When installing the sunshade board, do not let it block the air inlet at the side grille. [Diagram showing unit with sunshade board]

Drain water for one style

To get the maximum cooling efficiency, the air conditioner is designed to splash the condensate on the condenser coil. If the splashing sound annoys you, you can provide an outside drain by using the following procedure, which may however cause a small loss of performance.

  1. There is a drainage outlet at the back of the unit.
  2. Remove the cover from the drainage outlet, and then connect the drainage joint to it with a screw.
  3. Connect the drain hose to the outlet.

Note: Drain hose or tubing can be purchased locally to satisfy your particular needs.

[Diagram showing drainage outlet, cover, washer, drainage joint, and screw]

Drain water for another style

To get the maximum cooling efficiency, the air conditioner is designed to splash the condensation water on the condenser coil. For cooling-only units, if the splashing sound annoys you, you can provide an outside drain by using the following procedure, which may however cause a small loss of performance.

  1. Slide out the chassis from the cabinet.
  2. Remove the rubber plug from the body base plate.
  3. Install the drain pan to the corner of the cabinet with 2 screws.
  4. Connect the drain hose to the outlet on the drain pan bottom.
  5. Slide the chassis into its original place in the cabinet.

Note:

  • Drain pan and drain hose must be installed before using reverse cycle models.
  • Drain hose or tubing can be purchased locally to satisfy your particular needs.

[Diagram showing internal view with screws, drain pan, and drain hose; and external view with drain hose]

Notes for installation

Remove

Before removing the air conditioner to another place, you should contact the seller first. Then it must be done under the direction of a professional technician. In addition, the charge for this must be paid.

Noise

  • Install in a location where is firm enough to avoid the enlargement of noise and vibration.
  • Do not put anything in front of the outlet of the outdoor unit to avoid increasing noise.
  • Be sure that hot air or noise will not inconvenience neighbors.
  • Please contact the seller as soon as there is strange noise during operation.
  • Please use the safety support.

Electric wiring

  • Must connect with ground reliably.
  • The exclusive circuit must be used. But a removable socket cannot be used because poor contact can cause overheating or fire.
  • Do not pull the power cord strongly.
  • In a fixed circuit, there must be an electricity leakage protection switch and leakage current less than 30mA.
  • Connecting methods between air conditioners, power cords, and interconnecting methods of individual elements should accord with the wiring diagram on the unit.
  • The air conditioner should be installed in accordance with national wiring regulations.
  • An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.
  • An air switch (thermal-magnetic breaker) should be installed in the circuit.
  • If the supply cord is damaged, it must be replaced by the manufacturer, your dealer, or a qualified person to avoid a hazard.
  • All electrical work must be done according to the local wiring regulations.

Part identification

Unit Overview

Panel outlook picture, just for reference; please take the real unit as standard.

[Diagram labeling parts: Front intake grille, Air filter, Remote control panel, Power cord, Cabinet, Air inlet louver, Front grille]

Air direction adjustment

Vertical airflow direction vane

(Air flow direction adjustment up and down). The vertical airflow direction vane is controlled by positioning the vane to discharge the air upwards, downwards, or straight out. [Diagram showing the vertical airflow direction vane]

Remote control operation procedure

Buttons on remote controller

[Image of a remote control with numbered buttons]

  1. ON/OFF button
  2. MODE button
  3. +/- button
  4. FAN button
  5. SWING button
  6. SLEEP button
  7. TIMER button

Introduction for icons on display screen

[Diagram showing remote control display screen with labels for Timer on, Timer off, Sending signal, auto operation, cool operation, dry operation, fan operation, heat operation, SWING operation, SLEEP operation, LOCK, set speed, Set temperature, Set time]

Introduction for buttons on remote controller

Note:

  • This is a general-use remote controller; it could be used for air conditioners with multifunction. For some functions not present in a specific model, pressing the corresponding button on the remote controller will keep the unit in its original running status.
  • When power is connected (standby condition), you can operate the air conditioner through the remote controller.
  • When the unit is on, each time you press a button on the remote controller, the sending signal icon [signal icon] on the display will blink once. If the air conditioner gives out a beep sound, it means the signal has been sent.
  • When the unit is off, the set temperature will be displayed on the remote controller (if the indoor unit display light is turned on, the corresponding icon will be displayed). When the unit is on, it will display the icon of the on-going function.

1 ON/OFF button

Press this button to turn the unit on/off.

2 MODE button

Pressing this button once can select your required mode circularly as below (the corresponding icon will be lit up after the mode is selected): AUTO, COOL, DRY, FAN, HEAT (not applicable for cooling only model).

  • When selecting AUTO mode, the air conditioner will operate automatically according to ambient temperature. Set temperature cannot be adjusted and will not be displayed. Press the FAN button to adjust fan speed.
  • When selecting COOL mode, the air conditioner will operate under cool mode. Then press + or - button to adjust set temperature. Press the FAN button to adjust fan speed.
  • When selecting DRY mode, the air conditioner will operate at low fan speed. In DRY mode, fan speed cannot be adjusted.
  • When selecting FAN mode, the air conditioner will operate in fan mode only. Then press the FAN button to adjust fan speed.
  • When selecting HEAT mode, the air conditioner will operate under heat mode. Then press + or - button to adjust set temperature. Press the FAN button to adjust fan speed. (Cooling only units cannot receive heating mode signal. If HEAT mode is set by remote controller, pressing the ON/OFF button will not turn on the air conditioner.)

3 +/- button

Pressing the + or - button once will increase or decrease the set temperature by 1°F(°C). Hold the + or - button for 2 seconds, the set temperature on the remote controller will change quickly. Release the button after your required set temperature is reached.

When setting Timer On or Timer Off, press the + or - button to adjust the time. (See TIMER Button for setting details)

Introduction for buttons on remote controller

4 FAN button

Pressing this button can select fan speed circularly as: AUTO, SPEED 1 [low fan speed], SPEED 2 [mid fan speed], SPEED 3 [high fan speed]. SPEED 4 is unavailable in this air conditioner and is the same as SPEED 3.

  • Under Auto speed, the air conditioner will select proper fan speed automatically according to ambient temperature.
  • Fan speed cannot be adjusted under Dry mode.

5 SWING button

Press this button to turn on left & right air swing.

6 SLEEP button

Under Cool or Heat mode, press this button to turn on Sleep function. Press this button again to cancel Sleep function. Under Fan, Dry, and Auto modes, this function is unavailable.

7 TIMER button

  • When the unit is on, press this button to set Timer Off. The T-OFF and H icon will be blinking. Within 5 seconds, press the + or - button to adjust the time for Timer Off. Pressing + or - button once will increase or decrease the time by 0.5h. Hold + or - button for 2 seconds; the time will change quickly. Release the button after your required set time is reached. Then press the TIMER button to confirm it. The T-OFF and H icon will stop blinking.
  • When the unit is off, press this button to set Timer On. The T-ON and H icon will be blinking. Within 5 seconds, press the + or - button to adjust the time for Timer On. Pressing + or - button once will increase or decrease the time by 0.5h. Hold + or - button for 2 seconds; the time will change quickly. Release the button after your required set time is reached. Then press the TIMER button to confirm it. The T-ON and H icon will stop blinking.
  • Cancel Timer On/Off: If Timer function is set up, press the TIMER button once to review the remaining time. Within 5 seconds, press the TIMER button again to cancel this function.

Note:

  • Range of time setting is: 0.5~24h.
  • The interval between two motions cannot exceed 5 seconds, otherwise the remote controller will exit setting status.

Function introduction for combination buttons

Child lock function

Press the "+" and "-" buttons simultaneously to turn on or turn off the child lock function. When the child lock function is started, the LOCK indicator on the remote controller is ON. If you operate the remote controller, it will not send a signal.

Temperature display switchover function

Under OFF status, press the "-" button and the "MODE" button simultaneously to switch between °C and °F.

Operation guide

  1. After connecting the power, press the "ON/OFF" button on the remote controller to turn on the air conditioner.
  2. Press the "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT (not applicable for cooling only model).
  3. Press "+" or "-" button to set your required temperature. (Temperature cannot be adjusted under auto mode).
  4. Press "FAN" button to set your required fan speed: auto, low, medium, and high speed.

Replacement of batteries in remote controller

  1. Press the mark [battery cover release mark] on the back cover of the battery box for the remote controller with your fingers as shown in the figure, and then remove the batteries box cover along the arrow direction. [Diagram showing battery compartment opening]
  2. Replace with two (AAA 1.5V) dry batteries. Make sure positions for "+" pole and "-" pole are correct.
  3. Reinstall the batteries box cover.

NOTICE:

  • The distance between the signal sender and receiving window should be no more than 8m, and there should be no obstacles between them.
  • As the signal will be interfered with in the room by electronic fluorescent lamps, conversion fluorescent lamps, or wireless phones, please get closer to the air conditioner when using the remote controller.
  • Replace with new batteries of the same model when replacement is required.
  • When you do not use the remote controller for a long time, please take out the batteries.

Remote control panel

Note: If the wireless remote controller is lost, open the surface panel and operate manually.

[Diagram of the air conditioner's control panel with numbered buttons: 1 POWER BUTTON, 2 SWING BUTTON, 3 FAN SPEED BUTTON, 4 TEMP/TIMER BUTTON, 5 SIGNAL RECEIVER, 6 MODE BUTTON, 7 FILTER BUTTON]

  • 1 POWER BUTTON: Operation starts when pressing this button, and stops when pressing this button again.
  • 2 SWING BUTTON: Activate the automatic air swing function.
  • 3 FAN SPEED BUTTON: Select the fan speed HIGH, MID, LOW, and AUTO in sequence.
  • 4 TEMP/TIMER BUTTON: Press the keypad to increase the set (operating) temperature of the unit, and press the keypad to decrease the set (operating) temperature of the unit. The temperature setting range is from 16~30°C. Press the keypad also to increase the selected time in 1-hour increments, and press the keypad to decrease the selected time in 1-hour decrements. The time setting range is from 0~24 hours.
  • 5 SIGNAL RECEIVER
  • 6 MODE BUTTON: Select the operation mode: AUTO, HEAT, COOL, FAN, DRY (for reverse cycle model) or AUTO, COOL, FAN, DRY (for cooling only model).
  • 7 FILTER BUTTON: This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation and cooling. The LED light will illuminate after 250 hours of operation. To reset after cleaning the filter, press the "Check Filter" button, and the light will go off.

VENTILATION LEVER

When the slider is at the:

  • "OPEN" position: The ventilation door opens to allow air, smoke, or odors to be expelled from the room.

When the slider is at the:

  • "CLOSE" position: The ventilation door is closed, and the air will be circulated inside the room and conditioned.

[Diagram of the Ventilation Lever]

Operation Tips

Operation for comfort and economy

  • Do not overcool the room temperature. This is not good for health and wastes electricity.
  • Keep blinds or curtains closed. Do not let sunshine enter the room directly when the air conditioner is in operation.
  • Keep the room temp. uniform. Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room. Air cannot be discharged to the direction of air-in.
  • Make sure that the doors and windows are tightly closed. Avoid opening doors and windows frequently to keep air conditioning in the room.
  • Clean the air filter regularly. Blockages in the air filter reduce dehumidifying effects. Clean the air filter at least once every two weeks.
  • Ventilate the room occasionally. Since windows are kept closed, it is a good idea to open them and ventilate the room now and then. When starting the unit, curtains or windows should be closed to prevent heat/cool leakage.

[Illustrations for operation tips]

Caution

Operations for safety and health

  1. The plug must be accessible after the appliance is positioned.
  2. Do not use this appliance in the laundry.
  3. If the power cord is damaged, it must be replaced by the manufacturer or its service agent to avoid hazard.
  • Do not pull out the power cord. Damage to the cord may result in serious electric shocks.
  • Do not use the air conditioner for other purposes except for cooling the room. Do not use the air conditioner for other purposes such as drying clothes, preserving foods, or cultivating vegetables.
  • Do not block the air intake and outlet vents. This causes lowered performance and irregular operation. Do not insert sticks or other objects into these vents, as it is dangerous to touch the electric components and the fan.
  • Select the most appropriate temperature. Pay attention to adjust the temperature to suit the conditions. Rooms occupied by infants, the elderly, or the sick should be kept at an appropriate temperature.
  • Do not use heating apparatuses in the vicinity. The air conditioner's plastic parts will melt if exposed to excessive heat.
  • Avoid exposing the body directly to a continuous unidirectional airflow for long periods. This is not recommended for health reasons.

Always wait at least 3 minutes before switching the air conditioner on again after you have switched it off during cooling or heating. [Illustration showing a clock with 'Always wait at least 3 minutes']

Care and maintenance

Always turn off the air conditioner and main power supply before cleaning to ensure safety.

Cleaning unit

  1. Cut power off before cleaning. [Illustration showing unplugging power]
  2. Use a soft cloth when cleaning the cabinet. If the cabinet is very dirty, dip the cloth into warm water below 40°C, dry the cloth, and then rub off the dirt. [Illustration of cleaning with cloth]
  3. Do not use gas, benzene, solvent, wash, chemical solvent, etc. for cleaning. [Illustration showing prohibited cleaning agents]
  4. Do not splash water directly into the indoor unit, which contains micro-computers and circuit plates; they must not be drenched with water. [Illustration showing water splashing with a warning]

Air filter

The air filter behind the intake grille should be washed at least once every two weeks or as often as it needs cleaning.

How to clean the air filter:

  1. To remove the air intake grille, grasp the tab on the filter and pull to take out. [Illustration of filter removal]
  2. Vacuum the filter on the dusty side to remove light dust. [Illustration of vacuum cleaner]
  3. Wash the filter, cleaner side up, under gently flowing water to wash out accumulated dust and lint. [Illustration of washing filter]
  4. If the filter is very dirty, use a mild household detergent in the wash water. [Illustration of detergent bottle]

Let the filter dry thoroughly before reinstalling it. If necessary, please ask a professional personnel to clean it.

Checks

  • Check earth wire: Is it broken or loose? [Illustration of earth wire]
  • Check if air inlet and outlet of outdoor unit are blocked or not: Air lock could result in bad efficiency. [Illustration showing blocked vents with a warning]

Trouble shooting guide

Check the following points before calling for repair or service. If the malfunction persists, please contact Shun Hing Electric Service Centre Ltd.

Fault phenomenonTrouble-shooting
Air conditioner does not operate at all. [Diagram of unit with OFF indicator]
  • Is there a power failure?
  • Is the plug out?
  • Has the internal fuse blown?
  • Is voltage operated in rated range?
Cool or heat efficiency is not good. [Diagram of person looking at unit with 'No cooling' text]
  • Is air inlet or outlet locking?
  • Is there any other heat/cool source in room?
  • Are air filters dirty very much?
  • Is indoor fan speed set at LOW?
  • Maybe the room is too hot/cool when the unit is started.
Foggy air flows out.
  • At COOL mode operation, sometimes there is foggy air flowing out of the indoor unit; this is because the room humid air has been cooling rapidly.
  • The unit is normal if the indoor outlet is sending out some odor, because the inlet air may be mixed with the smell of furniture and smoke.
The air conditioner operation is noisy.
  • For a noise that sounds like water flowing: This is the sound of freon flowing inside the air conditioner unit.
  • For a noise that sounds like a shower: This is the sound of the dehumidifying water being processed inside the air conditioner unit.
It seems that condensation is leaking from air conditioner.
  • Condensation occurs when the airflow from the air conditioner cools the warm room air.
Air conditioner does not operate for about 3 minutes when restart.
  • This is to protect the mechanism.
  • Wait about three minutes and operation will begin.

Special Avowal

  1. The information above has been checked; the company reserves the hermeneutic power for any print errors or misunderstandings on the content.
  2. Any technology improvement will be added to new instructions without any prior notices. The product appearance and color refer to the practical air conditioner.
  3. An e-copy of the user manual can be sent by email upon request; please call Shun Hing Electric Works & Engineering Co. Ltd. hotline at 2861 2767.

After sale service

Guarantee period is one year from the date of purchasing. If the product is damaged under proper use, a free repair service is available. Please present the official invoice and the guarantee certificate with the sales point's chop / redemption center's chop for free maintenance. For enquiries, please contact Shun Hing Electric Service Centre Limited hotline at 2406 5666.

Turn off the power and contact Shun Hing Electric Service Centre Ltd. as soon as any of the following events occur:

  • The circuit breaker frequently trips or the fuse blows regularly.
  • If water or foreign objects have accidentally entered the air conditioner.
  • If there is abnormal sound during operation.

Contact Information

Shun Hing Electric Works & Engineering Co., Ltd

Office: 9/F, Peninsula Centre, 67 Mody Road, Tsimshatsui East, Kowloon, Hong Kong

Tel: (852) 2861 2767 | Fax: (852) 2865 6706

Website: www.rasonic.com | Email: shew@shunhinggroup.com

Shun Hing Electric Service Centre Ltd.

Office: 11th Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong

Tel: (852) 2406 5666 | Fax: (852) 2408 0316

Website: www.shesc.com

Consumables/ Accessories Sales Hotline

Tel: (852) 2406 5666

Customer Service Centres

Hong Kong: 1st Floor, Shun Hing Centre, 2 Shing Yiu Street, Kwai Chung, New Territories, Hong Kong

Tel: (852) 2406 5439 | Fax: (852) 2408 1389

Macau: Avenida De Venceslau De Morais, No. 193-199, 5 Andar-I, Edificio Industrial Nam Leng, Macau

Tel: (853) 2836 2928 | Fax: (853) 2833 6405

For the latest information of customer service centres, please visit www.shesc.com or call us at our hotline.

Models: RC-X7HA, RC-X9HA, RC-X12HA, RC-X18HA, Window Type Air Conditioner, Window Type AC, Air Conditioner, AC, RC Series Window Type Air Conditioner

File Info : application/pdf, 24 Pages, 853.20KB

PDF preview unavailable. Download the PDF instead.

RC-X HA user manual EN-L

References

Acrobat Distiller 3.01 for Windows

Related Documents

Preview Rasonic Window Type Air Conditioner Operating Instructions & Manual
Comprehensive operating instructions and user manual for Rasonic window type inverter cooling air conditioners (Models RC-S70H, RC-S90H, RC-S120H, RC-S180H, RC-S240H). Includes installation, operation, maintenance, troubleshooting, and safety guidelines.
Preview Rasonic Window Type Air Conditioner User Manual
User manual for Rasonic window type air conditioners, covering installation, operation, maintenance, and troubleshooting. Includes safety precautions and product specifications.
Preview Rasonic Window Type Air Conditioner User Manual
User manual for Rasonic Window Type Air Conditioner (Cooling Only) models RC-XG7, RC-XG9, RC-XG12, and RC-XG18. Includes installation, operation, maintenance, and troubleshooting information.
Preview Rasonic R410A Window Type Air Conditioner User Manual - Models RC-X7KM, RC-X9KM
This user manual provides comprehensive instructions for operating, installing, and maintaining the Rasonic R410A Window Type Air Conditioner, models RC-X7KM and RC-X9KM. It includes safety precautions, parts identification, operating modes, troubleshooting tips, and specifications.
Preview Rasonic Air Conditioners: Innovative Features and Energy Efficiency
Explore the Rasonic range of inverter air conditioners, featuring nanoe-G air purification, AEROWINGS dual-layer louvers, and energy-saving technology. Find models for cooling and heating with detailed specifications.
Preview Rasonic Air Conditioners: Advanced Features, Energy Efficiency, and Model Guide
Explore the Rasonic air conditioner range, featuring nanoe-G air purification, Inverter technology, AEROWINGS airflow, and energy-efficient models. Find specifications and features for cooling and heating solutions.
Preview Rasonic R32 變頻淨冷 窗口式冷氣機 遙控器操作說明書
本說明書提供 Rasonic R32 變頻淨冷 窗口式冷氣機遙控器的全面操作指南,涵蓋按鈕功能、顯示指示、操作方法及處理須知,適用於 RC-S701AC、RC-S901AC、RC-S1201AC 及 RC-S1801AC 型號。
Preview Rasonic RC-HZ180Z/RC-HZ240Z Air Conditioner Operating Instructions
This document provides comprehensive operating instructions and installation guidance for Rasonic RC-HZ180Z and RC-HZ240Z air conditioners. It covers essential safety precautions, detailed installation procedures, various operating modes, maintenance tips, and troubleshooting advice to ensure optimal performance and user safety.