Hilti HCW 37x45 M12 Anchor System Installation Guide

Brand: HILTI

Product: HCW 37x45 M12 Anchor System

Step 1: Prepare the Base Material

Ensure the hole depth (h1) is a minimum of 70mm. The required hole diameter is between 36-37mm.

Diagram Description: A cross-section of concrete shows a rectangular cutout representing the hole. Dimensions are labeled: 'h1' indicating depth, and '36-37mm' indicating diameter.

Step 2: Insert the HCW Sleeve

Insert the HCW sleeve (HCW SW) into the prepared hole. Use the SIW 22T-A 1/2" tool for insertion.

Diagram Description: The concrete hole from Step 1 is shown. A tool (SIW 22T-A 1/2") is depicted engaging with the HCW sleeve, pushing it into the hole. Red arrows indicate the direction of insertion.

Step 3: Verify Sleeve Placement

Visually inspect the sleeve for proper seating ?️. Ensure the internal threads are clean and undamaged ✔️. Avoid incorrect insertion angles ?.

Diagram Description: The sleeve is shown seated in the concrete. Two magnified views highlight the internal threads. One shows clean, correctly formed threads with a checkmark ✔️. The other shows damaged or misaligned threads with a prohibition symbol ?. An eye icon ?️ indicates visual inspection.

Step 4: Install Hanger Bolt and Nuts

The total thickness of the material being attached (t2) must be between 40mm and 55mm. Install the Hanger Bolt HSW 12x220/60 8.8 (compatible with HST3 M12, HAS-U M12 8.8). Ensure correct nut and washer placement.

Diagram Description: A hanger bolt is shown installed through a layer of material and into the anchor sleeve in the concrete. A magnified inset shows the bolt, nuts, and washers. The dimension 't2' indicates the material thickness. A red dashed line represents the required embedment depth. Two configurations are shown: one with incorrect nut/washer placement (indicated by ?) and one with correct placement (indicated by ✔️).

Step 5: Multiple Attachments and Safety

When installing multiple anchor points, ensure proper spacing and alignment. Observe the required embedment depths for HCW L and HCW components. Be aware of potential pinching or crushing hazards ⚠️. Follow the indicated direction of assembly ⬇️.

Diagram Description: Two anchor bolts are shown installed. One diagram illustrates the use of HCW L and HCW components. A yellow warning triangle with a hand icon ⚠️ signifies a pinch hazard. A red arrow ⬇️ indicates the direction of assembly or insertion.

Step 6: Final Check and Alignment

Perform a final visual inspection ?️. Ensure the hanger bolt is installed perpendicular to the surface (90°). Incorrect angles are not permitted ?.

Diagram Description: The fully installed anchor bolt is shown. A magnified view shows the bolt head and nut assembly. A 90° symbol is displayed to emphasize correct alignment. An incorrect angled installation is shown with a prohibition symbol ?.

Models: HCW 37x45 M12 Wood Connectors, HCW 37x45 M12, Wood Connectors, Connectors

PDF preview unavailable. Download the PDF instead.

Operating-Instruction-HCW-37x45-M12-Operating-Instruction-PUB-5621831-000 Adobe PDF library 16.03 Adobe Illustrator 26.0 (Macintosh)

Related Documents

Preview Hilti Coupler Wood (HCW) Technical Guide: Fast & Efficient Timber Fastening
Explore the Hilti Coupler Wood (HCW) system, a technical guide detailing its applications, design information, and load resistances for fast and efficient timber fastening in prefabricated construction. Learn about HCW, HCW-S, HCW-L, and HCW-UP connectors for robust timber connections.
Preview Hilti HCW-L 40x375 M12 Anchor System Installation Guide
Step-by-step instructions and technical details for installing the Hilti HCW-L 40x375 M12 anchor system, including required components, dimensions, and tools.
Preview Hilti HCW-UP 37x35 M12 Anchor Installation Guide
Comprehensive installation guide for the Hilti HCW-UP 37x35 M12 anchor system, detailing hole preparation, anchor selection, fastening procedures, and application variants with safety guidelines.
Preview Hilti HST3 DN and HST3-R DN M12 Anchor Installation Guide
This guide provides detailed instructions and technical specifications for installing Hilti HST3 DN and HST3-R DN M12 anchors, including drilling, cleaning, and setting procedures.
Preview Hilti HST3 M12 Concrete Anchors: Technical Specifications and Installation Guide
Comprehensive guide to Hilti HST3 M12 series concrete anchors, detailing technical specifications, installation procedures, and key measurements for safe and effective use.
Preview Hilti HCW-S 37x45 M12 Installation Guide
This document provides installation instructions for the Hilti HCW-S 37x45 M12 anchor, detailing the necessary tools, components, and steps for secure and proper installation.
Preview Hilti MP-PS BP Installation Guide
This document provides installation instructions and technical specifications for the Hilti MP-PS BP system, including details on components, assembly, and dimensions.
Preview Hilti HST3 Anchor Installation Guide and Specifications
Comprehensive installation instructions and technical specifications for Hilti HST3 and HST3-R concrete anchors, detailing drilling, cleaning, setting, and tightening procedures with critical dimensions and torque values.