BRISTAN
Installation Instructions & User Guide
Please leave these instructions with the end user.
Product Codes: FZ SHXMMCTFF C (D2), FZ SHXVOCTFF C (D2)
Specifications
Working Pressures | Min: 0.2 bar, Max: 5.0 bar |
---|---|
Inlet Water Temperature | Cold Water Supply: Min: 5°C, Max: 25°C Hot Water Supply: Min: 60°C, Max: 65°C (60-65°C Recommended) IMPORTANT: The inlet hot water must be at least 10°C above the required blend temperature. |
Maximum Static Pressure | 10.0 bar |
Inlet Dimensions | 150mm Centres |
Inlet Connections | 15mm Compression |
TMV2 Designation | HP-S & LP-SE |
Tools You'll Need
- Pencil
- Flat head Screwdriver
- Drill
- Cross head Screwdriver
- Spanner
- Pipe Cutter
- Hexagonal Keys
- Socket Spanner
Prior to Installation
All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc.
This product must not be modified in any way as this will invalidate the guarantee.
Full access must be made available for future maintenance/servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This can be checked with the aid of an electronic detector.
If power tools are used, remember to: Wear eye protection, Unplug equipment after use.
If in doubt, contact a registered plumber or your Local Water Authority or the Secretary of the Institute of Plumbing, address as follows: The Institute of Plumbing, 64 Station Lane, Hornchurch, Essex, RM12 6NB. Tel: 01708 472791.
Pack Contents
- Shower Head x2
- Hose x2
- Wall Bracket x1
- Fixing Kit x1 (Supplied with FZ SHXMMCTFF C only)
- Hose Retainer x1
- Slider x1
- Top Bracket x2
- Bottom Bracket x2
- Isolator x8
- Olive x8
- Cover Plate x2
- Concealing Cap x1
- Filter Washer x2
Installation
Step 1: Identify the required position of the valve and prepare the water supply pipes. Supply pipes should be 150mm apart. Using the backplate supplied with the wallmount, mark and drill holes.
Step 2: Secure the rubber backplate and backplate into place.
Step 3: Secure the isolator onto the backplate, ensuring the olive is positioned over the pipework correctly.
Step 4: Push shrouds to the back of the wall outlet, securing them against the rubber fixing plate.
Step 5: Insert filter washer and secure the shower to the wall mount.
Step 6: Remove the concealing cap from the shroud.
Isolation
Step 1: Rotate the shroud until the opening aligns with the isolation screw. Turn the screw to isolate the water. Reverse the process when turning the water back on.
Operation
IMPORTANT: Please refer to the TMV booklet for commissioning and testing guidance.
Temperature Control: To override the 38°C pre-set temperature, push the temperature control button down and turn the handle towards you to increase the temperature.
Temperature Setting
Step 1: Turn the shower on, letting the temperature stabilise.
Step 2: Remove the cap, screw, and temperature handle.
Step 3: Turn cartridge spindle clockwise to decrease the temperature.
Step 4: Turn cartridge spindle anti-clockwise to increase the temperature.
Step 5: Reverse steps 1-2 to reinstall the cartridge and handle.
Maintenance - Cartridge Cleaning
Step 1: Remove temperature and flow handle.
Step 2: Unscrew the flow valve.
Step 3: Remove adaptor, nut, and cartridge.
Step 4: Remove O-rings and soak all components in de-scaler and wash off in clean water. Examine all seals and replace if needed. Use WRAS approved silicon-based grease on all seals.
Step 5: Replace cartridge and turn spindle anti-clockwise to maximum temperature.
Step 6: Replace nut and adaptor. Ensure the raised side is facing towards the back of the valve.
Step 7: Turn cartridge spindle clockwise to decrease the temperature. Turn cartridge spindle anti-clockwise to increase the temperature.
Step 8: Slide handle onto adaptor and turn clockwise until you meet resistance.
Step 9: Reverse steps 1-2 to reinstall the valve and secure handles.
Riser Installation (not supplied with FZ SHXVOCTFF C)
Step 1: Assemble the riser, attaching the hose retainer, slider, and both the top and bottom brackets.
Step 2: Use the assembled riser to mark the desired position for the riser on the wall.
Step 3: Drill the marked holes.
Step 4: Slide top bracket onto riser and secure to wall.
Step 5: Insert riser rail into lower bracket and secure to the wall.
Step 6: Slide hose through hose retainer before attaching the handset to the shower.
Servicing Intervals
To reduce the build-up of limescale and to ensure this shower works to its maximum performance, we recommend this shower is serviced every 6-12 months depending on the hardness of your water.
Spare Parts
To replace any spare parts for your shower, visit bristan.com and search for your product.
Troubleshooting
Symptom | Cause | Remedy |
---|---|---|
No flow or low flow rate | Partially closed isolation valve. Instantaneous water heater cycles on and off as flow rate or pressure is too low. Head of water is below the minimum distance required. Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes. Airlock or partial blockage in the supply pipework. | Open isolation valve. Increase water flow rate or pressure through system. 2 meters minimum required. Do not use other water outlets when using the taps. Flush through pipework to ensure removal of debris and any airlocks. |
Water dripping from shower | This is normal for a short time after using the shower. If water continues to drip, possibly due to the cartridge. | This is caused by residual water tension, the build up of water in the shower. Remove cartridge and clean, refer to 'Maintenance' section before starting any maintenance. |
Shower does not turn on | Closed isolation valve. Mains water supply turned off. | Open isolation valve. Turn on mains water supply. |
Guarantee and Support
At Bristan, we want to make things as easy as possible for our customers. That's why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee, register your product at www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions, visit www.bristan.com/guarantees.
We Know & We Care