Bristan SI PROSNK C (D3) Sink Mixer
Installation Instructions & User Guide
Product Information
Product Code: SI PROSNK C (D3)
Specifications
Dynamic Water Pressure
Minimum: 1.5 bar
Maximum: 5.0 bar
A pressure gauge graphic shows a scale from 0.2 to 5.0 bar, with recommended operating range highlighted between 1.5 and 5.0 bar.
Maximum Static Pressure
10.0 bar
Inlet Water Temperature
Cold Water Supply: Minimum 5°C, Maximum 25°C
Hot Water Supply: Maximum 60°C (Recommended)
A thermometer graphic indicates temperature ranges, showing minimums of 5°C for cold and maximums of 25°C for cold and 60°C for hot, with 60°C marked as recommended.
Inlet Connections
G1/2" Flexible Tails
Flexible G1/2" tails are shown, with markings indicating 'red for hot' and 'blue for cold'.
Tools You'll Need
- ? Adjustable Spanner
- ? Pipe Cutter
- ? Hexagonal Key
- ? Crosshead Screwdriver
Spare Parts
To replace any spare parts for your tap, scan the QR code or visit www.bristan.com and search for your product.
A QR code is provided for easy access to spare parts information on the Bristan website.
Pack Contents
- 1x Tap Body
- 1x Flexible Hose
- (Other components as per installation steps)
The pack contains 1x tap body and 1x flexible hose, among other necessary installation components.
Prior to Installation
All Bristan products are safe to use when installed, operated, and maintained according to these instructions.
Installation must comply with the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full details, visit wras.co.uk/directory.
❗ IMPORTANT: Isolation valves must be fitted to the inlet water supplies for ease of future maintenance.
Before installation, thoroughly flush the water supply to remove any debris (swarf, solder, etc.). Ensure full access is available for future maintenance or servicing.
This product must not be modified, as this will invalidate the guarantee.
If in doubt, contact a registered plumber, your Local Water Authority, or the Institute of Plumbing.
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB,
Tel: 01708 472791
Warning from Your Water Supplier
It is a criminal offence to use this tap with a mains water supply drawn directly from the supply pipe. This tap has an outlet on a flexible hose, which if immersed in water, could result in contaminated water being back-drawn into the pipework if the supply pressure dropped.
To prevent contamination and comply with UK plumbing regulations, both hot and cold water supplies to this tap must come from a storage cistern.
If distributing pipes from the storage cistern have other outlets, this tap's outlet must be lower than those other outlets.
If the water from the storage cistern is not suitable for drinking, a separate tap supplied with wholesome water must be provided for drinking purposes.
For more information, contact your Local Water Supplier's Water Regulations Department (see wras.co.uk) or the Water Regulations Advisory Scheme by email (info@wras.co.uk) or telephone: 0333 207 9030.
Installation
Step 1
Feed the pipes through the sink hole and place the tap body.
Illustration shows feeding the flexible pipes through the sink hole and positioning the tap body.
Step 2
Feed all pipes through the nut, screw onto the threaded pipe, and tighten screws to secure.
Illustration depicts passing the pipes through a securing nut, screwing it onto the tap's threaded pipe, and tightening.
Step 3
❗ IMPORTANT: Fit isolation valves for future maintenance.
Connect the hot and cold water connections using the olive and compression nut.
Diagram shows connecting the hot and cold water supply hoses to the tap, using olives and compression nuts. A warning icon highlights the importance of fitting isolation valves.
Step 4
REMEMBER: Hot on the left, cold on the right.
Switch on the water supply and check connections for any leaks.
Illustration shows turning on the water supply and checking all connections for leaks. A reminder graphic states 'Hot on the left, cold on the right'.
Flexible Connecting Pipes
These pipes can accommodate various installation needs:
- Slight bend
- 90° angle
- Curved round
- Kinks (avoid sharp kinks)
- Twists (avoid excessive twisting)
Visuals demonstrate the flexibility of the connecting pipes, showing examples of a slight bend, a 90° angle, a curved round shape, and warnings against sharp kinks or excessive twists.
Operation
The tap controls are as follows:
- Lever: Off, On (Hot/Cold selection)
- Spray Function: Press button on the spout for spray.
- Aerated Water Function: Standard flow.
A diagram illustrates the tap lever's positions: Off, On (with Hot and Cold indicated). It also shows the spray function activation and mentions the aerated water flow.
Maintenance - Cleaning/Replacing Cartridge
❗ IMPORTANT: Isolate the water supply before starting!
Step 1
Remove the decorative cap. Undo the grub screw and remove the handle.
Illustration shows how to remove the tap handle by first removing a cap, then undoing a grub screw.
Step 2
Unscrew the shroud and retaining nut. Remove the cartridge.
Diagram shows unscrewing the tap's shroud and retaining nut to access and remove the cartridge.
Step 3
Visit www.bristan.com or scan the QR code to find and order the correct replacement cartridge for your tap.
A QR code is displayed, linking to the Bristan website for ordering replacement cartridges.
Step 4
Reverse the steps to replace the valves and handles.
Maintenance - Replacing Handset
❗ IMPORTANT: Isolate the water supply before starting!
Step 1
Unscrew the handset from the hose. Replace with the new handset.
Illustration shows unscrewing the existing tap handset from its flexible hose and attaching a new one.
Step 2
Turn on the tap to check connections for any leaks.
Troubleshooting
Symptom | Cause | Remedy |
---|---|---|
Partially closed isolation valve. | Head of water is below the minimum distance required. | Open isolation valve. |
No flow or low flow rate | Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes. | Do not use other water outlets when using the taps. |
Airlock or partial blockage in the supply pipework. | Flush through pipework to ensure removal of debris and any airlocks. | |
Water dripping from taps | This is normal for a short time after using the taps. | This is caused by residual water tension, the build up of water in the tap body. |
If water continues to drip, possibly due to the ceramic disc valves | Remove valves and clean, refer to 'Maintenance' section before starting any maintenance. | |
Taps do not turn on | Closed isolation valve. | Open isolation valve. |
Mains water supply turned off. | Turn on mains water supply. | |
Hose doesn't release/re-turn properly | Hose is blocked/kinked/twisted or snagged on other objects. | Isolate the water supply and check the hose for any blockages or defects. Ensure the area is clear so the hose can't get snagged on other objects. |
Handset Pressure Changes | Site water pressure is too high for the working pressures listed on the specification. | Install a Pressure Reducing Valve in order to achieve working levels of pressure. |
General Cleaning
Bristan products are made from premium materials with hand-polished, PVD, EPD, or electroplated finishes.
Clean your tap regularly with warm water, a mild pH-neutral liquid soap, and polish with a soft cloth. Rinse off any residues from soap, toothpaste, shampoos, and shower gels immediately to prevent blemishes.
Avoid household bleaches, harsh cleaners, abrasive cloths, scouring pads, scrub sponges, or steel wool, as they can damage the surface finish.
Some surfaces (e.g., nickel, pewter) may be affected by dyes in cloths. Avoid hanging cloths on spouts.
Our Guarantee
Bristan offers solid guarantees on all products for peace of mind. To start your free guarantee, scan the QR code and register your product, or visit www.bristan.com/register.
A QR code is provided for quick product registration to activate the guarantee.
For queries, contact Customer Service on 0330 026 6273.
For full guarantee terms and conditions, visit www.bristan.com/service-centre/guarantees.
Contact Us
Bristan Group Ltd.
UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l., 14 Rue Strachen, 6933 Mensdorf, Luxembourg
Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquire@bristan.com
A Masco Company