ARRI SkyPanel S360-C Short Instruction
Kurzanleitung / Guide Rapide / 簡易説明書
Date: 07 / 2019
Model: S360-C
Manufacturer: Arnold & Richter Cine Technik GmbH & Co. KG
Website: www.arri.com
Intended Use
This product is intended to illuminate persons and objects in a dry environment.
Always follow the safety information.
Any usage other than described above is not permitted and can damage the product and lead to associated risks such as short-circuit, fire, electric shock, etc. Modification of the product is not allowed.
This product fulfills legal requirements.
General Notes
- The SkyPanel soft lights are intended for professional use and may only be operated by qualified persons.
- Please read these instructions carefully before using the product for the first time.
- For your personal safety, observe the safety instructions and warnings in this manual and the Safety and Installation manual (L5.0016680), available at www.arri.com.
- Observe all common and local safety regulations.
- Keep these instructions for possible subsequent owners.
- Dispose of packing material at your local recycling center for environmental protection.
- Dispose of defective products appropriately; consult your ARRI dealer or local authorities for information.
- Use only original ARRI spare parts and accessories.
Safety Instructions
DANGER OF LIFE - MAINS VOLTAGE!
Do not open the housing of the SkyPanel or the power supply. The housing must be completely closed for safe operation.
Always earth the fixture electrically. Use only TN- or TT single-phase power supplies with an IEC 60309-1 compliant plug.
Use only genuine ARRI Power Supply Units (PSU) and connector cables. Using third-party accessories voids the warranty.
Do not use cables to hold, move, or suspend the fixture or PSU.
Check cables and connectors for damage before each operation.
Do not connect or disconnect the power cable when the PSU is powered.
Do not operate if cables or housings are visibly damaged. Contact an ARRI service center for repairs.
CAUTION – HIGH BEAM INTENSITY!
Do not look directly into the active light source of the SkyPanel.
Observe minimum distances to persons and flammable objects as specified on the type plate.
Warnings
Do not cover ventilation slots of the fixture or PSU. Ensure unobstructed airflow for cooling.
Avoid direct illumination from other fixtures or heat sources.
Securing the Fixture and Accessories
For hanging or overhead use, use a suitable safety cable to prevent falling if the primary mounting fails. The safety cable and connectors must be rated for at least 10 times the total weight of the device and accessories.
Route the safety cable around the yoke and through the safety loop attachment (Version 1 & 2) or short yoke (Version 3), and secure it to the rigging structure.
Keep the safety cable short.
Ensure both locking pins (A) snap firmly into the diffuser/intensifier guide holes.
Insert accessories correctly into the accessory guiding rails.
Attach a rated safety cable to the accessory's safety hole and secure it to the rigging structure or the SkyPanel yoke's safety loop attachment (C).
Do not store the remote control in the trough when operating overhead.
The four eyelets (5) can be used for horizontal suspension. Use four safety cables, one for each eyelet, secured with a shackle to a single hoist point.
Ensure tripods are stable and rated for the load. Refer to "Operating your ARRI Lampheads Safely" L5.40731.E.
Basic Functions
Mounting
Mount the SkyPanel on its yoke (2) vertically or hanging. Insert the 28 mm spigot (1) into a suitable stand or clamp system and secure it.
Pan and Tilt
Swivel the SkyPanel by loosening the stand/clamp screw. Adjust tilt angle by releasing tilt locks (3). Retighten screws/clamps after adjustment.
Adjusting the Beam Angle
The beam angle can be adjusted using different diffuser panels (6) or the intensifier.
Parts Identification
SkyPanel S360-C Fixture
Part | Description |
---|---|
1 Spigot | Mounting stud |
2 Stirrup | Lyre |
3 Tilt lock | Tilt lock |
4 Handle | Handle |
5 Eyelet | Eyelet |
6 Diffuser / Intensifier | Diffuser / Intensifier |
A Locking Pin | Locking Pin |
B Guiding Pin | Guiding Pin |
C Safety loop attachment | Safety loop attachment |
SkyPanel S360 PSU
Part | Description |
---|---|
13 Fixture menu | Fixture menu |
14 DC 54 V Output | DC 54 V Output |
15 Power in | Power in |
16 Power switch | Power switch |
Connectors on PSU
Part | Description |
---|---|
7 Antenna for wireless DMX | Antenna for wireless DMX |
8 USB A port | USB A port |
9 DMX input | DMX input |
10 DMX through | DMX output |
11 Ethernet connector RJ45 | Ethernet connector RJ45 |
12 DC 54 V Input | DC 54 V Input |
Using Light Shaping Accessories
Accessories like honeycombs can be inserted into the diffuser's guiding rails:
- Open locking pins (A) by pulling them out. Tilt the diffuser forward.
- Slide the accessory from above into the guiding rails.
- Open locking pins (A) again. Tilt the diffuser back. Ensure pins (A) snap into the guide holes.
Interfaces
DMX Interface
The SkyPanel has two locking 5-pin XLR connectors (10 & 11) for DMX/RDM data input and throughput.
USB Interface
The SkyPanel has a USB A interface (9) for firmware uploads via a FAT32 formatted USB 1.0/2.0 memory stick. Store firmware in the root directory.
WARNING: Check the USB port setting in the 'USB Mode' menu to 'Normal' before connecting the memory stick.
Ethernet Connector
The SkyPanel has an RJ45 Ethernet connector (12) for firmware updates, parameter settings, and service using the ARRI Lighting Service Manager. Download the latest firmware and software from www.arri.com.
Wireless DMX Interface
The SkyPanel S360-C includes a LumenRadio Wireless DMX (CRMX) receiver for DMX and RDM communication. Activate via the 'DMX Settings' menu and set 'Wireless DMX Data State' to 'On'. Link your transmitter by pressing its 'Link' button.
Power-On and Operation
Switching on the power (or applying mains power) starts the SkyPanel after a short startup time, retaining the last active settings.
Control the SkyPanel via DMX, USB, or the integrated fixture menu (16).
Modes of Operation
White Light
Generates white light with optimized color rendition. Color temperature and green/magenta point are continuously adjustable.
Colored Light
Generates white or colored light. Hue and saturation are continuously adjustable. At very low saturation, it produces white light without optimized color rendition.
Switch modes by briefly pressing the MODE button.
Indication Panel and Fixture Menu
The SkyPanel features an integrated fixture menu with the following functions:
POWER-LED
Color | Indication |
---|---|
Green | Fixture on, no error. |
Off | Fixture off. |
DATA-LED
Color | Indication |
---|---|
Blue | Receiving valid DMX signal. |
Blue/Green | Receiving valid wireless DMX signal. |
Purple | Master mode active. |
White | Receiving valid Art-Net signal, Gateway active. |
Green | Receiving valid Art-Net signal, Gateway not active. |
Orange | Receiving valid sACN signal, Gateway active. |
Cyan | Receiving valid sACN signal, Gateway not active. |
Red | No communication between fixture menu and controller board. |
No light | No valid control signal received. |
STATUS-LED
Color | Indication |
---|---|
Green | No error, normal temperature. |
Red flashing (0.5s rhythm)* | Warning: fixture near overheating (only with fan modes LOW and High Speed). |
Red* | Fixture overheating. |
Change from red to green* | Fixture normal temperature. |
Red flashing (0.25s Rhythm)* | Calibration data not loaded. |
*Display lights up red when STATUS-LED is lit red.
INTENSITY/SELECTOR ENCODER
- To set intensity.
- Turn and press to select a menu or confirm a parameter.
Central Rotary Knob
Functionality is shown on the display. Use for:
- Adjusting correlated color temperature (CCT) in white light mode.
- Adjusting color hue in colored light mode.
Right Rotary Knob
Functionality is shown on the display. Use for:
- Adjusting correlated green/magenta correction in white light mode.
- Adjusting color saturation in colored light mode.
Button Functions
MENU button: Opens or closes the fixture menu.
BACK button: Exits a sub-menu without saving changes. Returns to the previous menu level.
MODE button: Switches between White Light and Colored Light modes.
PRESET button: Opens the preset list. Use the SELECTOR encoder to select a preset.
User Manual & Service
User Manual
The SkyPanel 360-C user manual provides more detailed information on features and functionalities. Download it and other information from www.arri.com.
Replacing the Light Source
The light source is replaceable by a qualified service agent. If the light source reaches the end of its operational life or fails prematurely, contact the manufacturer or their service agent.
ARRI Service
For technical problems, visit www.arri.com.
Arnold & Richter Cine Technik GmbH & Co. KG
Global Application & Services
Arriweg 17
D-83071 Stephanskirchen
Germany
Design and specifications are subject to change without notice.
Specifications
SkyPanel S360-C
Specification | Value |
---|---|
Input Voltage | 100 - 240 V~, 50/60 Hz |
Max. cable length PSU - luminaire | 32 ft. (10 m) |
Power Consumption | 1500 W maximal |
Ingress Protection | IP20 dry location |
Protection Class | III |
Risk Group | 0 |
Operating temperature | ta = -20°C - +45° C / -4 to +113° F (High Mode / Variable Mode, 1200 W) ta = -20°C - +40° C / -4 to +104° F (Normal Mode, 1500 W) ta = -20°C - +35° C / -4 to +95° F (Quiet Mode, 1200 W) |
Dimensions (WxHxD) | 62.8 x 48.7 x 8.0 in (1594 x 1237 x 203 mm) |
Weight | 92 lbs (with carbon fiber yoke and diffuser) / 42 kg (with carbon fiber yoke and diffuser) |
Certifications | CE, FCC, CB, ENEC, cNRTLus, PSE |
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
SkyPanel S360-C Power Supply Unit
Specification | Value |
---|---|
Mains input | 100 - 240 V~, 50/60 Hz |
Voltage output | DC 54 V=== |
Dimensions (LxWxH) | 17.7 x 9.4 x 8.1 in (451 x 240 x 206 mm) |
Weight | 24.7 lbs / 11.2 kg |
ARRI, ARRI ARRI, the ARRI Logo, ARRIMAX, ARRISUN, EB, L-Series, MAX Technology, M-Series, POCKETPAR, True Blue, SkyPanel, SKYPANEL, T 12 and T 24 are registered trademarks of Arnold & Richter Cine Technik GmbH & Co. Betriebs KG.