Altronix NetWay4E Series
4-Port Ethernet over Fiber PoE+ Hardened Switches
Visit altronix.com for the latest firmware and installation instructions.
Models Include:
- NetWay4EWP: 4-port Hardened PoE Switch with Power Supply/Charger. NEMA4/4X, IP66 rated Outdoor enclosure.
- NetWay4EX: 4-port Hardened PoE Switch with Power Supply/Charger. NEMA1 rated Indoor enclosure.
- NetWay4EWPX: 4-port Hardened PoE Switch with Power Supply/Charger. NEMA4/4X, IP66 rated Outdoor enclosure. Accommodates up to four (4) 12VDC/4AH batteries.
- NetWay4EWPN: 4-port Hardened PoE Switch. NEMA4/4X rated outdoor enclosure.
- NetWay4EPL: 4-port Hardened PoE Switch with Power Supply/Charger. Backplane version.
- NetWay4EB: 4-port Hardened PoE Switch. Board Only.
Overview
Altronix NetWay4E Series Hardened PoE Switches are equipped with one (1) 1Gb SFP port and four (4) PoE IEEE802.3af/3at ports rated at 30W each, limited to the total power of the power supply employed. Embedded LINQ Technology enables monitoring, control, and reporting from anywhere over the network.
Features
Agency Listings
- UL/cUL Listed for Information Technology Equipment (UL 60950-1), Information Technology Equipment to Be Installed Outdoors (UL 60950-22).
- CE European Conformity.
Input
- 115VAC, 60Hz, 2.5A or 230VAC, 50/60Hz, 1.3A.
- NetWay4EB/NetWay4EWPN: 48-56V UL Listed ITE power supply.
Power Output
- Four (4) 10/100/1000 Mbps Ethernet ports rated at 30W each (limited to 120W total power).
- NetWay4EB/NetWay4EWPN: Four (4) 10/100/1000 Mbps Ethernet ports rated at 30W each (depending on the power supply employed).
- IEEE 802.3af, 802.3at compliant.
SFP Ports
- One (1) Gigabit SFP port.
Ethernet Ports
- Four (4) 10/100/1000 Mbps ports.
- Connectivity: RJ45, auto-crossover.
- Wire type: 4-pair CAT5e or higher structured cable.
- Speed: 10/100/1000 Mbps, half/full duplex, auto negotiation.
LINQ Technology
- Remote network management allows for camera/device reset and diagnostic monitoring.
- Provides local and/or remote access to critical information via LAN/WAN.
- Email and Windows Dashboard Alert notifications report real-time events.
- Event log tracks history.
VLAN
- Multiple management VLAN assignment.
- 802.1Q Tagged VLAN.
- Up to 10 VLAN groups. ID Range 2-4095.
Indicators (LED)
- Individual PoE On LEDs for each port.
- Individual IP Link status, 100/1000 Base-T/active LEDs for each port.
- ALOS LED indicates fiber connection for SFP port.
- Heartbeat LED indicates proper operation of the unit.
Mechanical
- NetWay4EB: Dimensions (L x W x D approx.): 6.25" x 4.5" x 0.625" (158.8mm x 114.3mm x 15.9mm).
- NetWay4EPL: Dimensions (H x W x D approx.): 10.75" x 8.875" x 2.375" (273.1mm x 225.4mm x 60.3mm).
- NetWay4EWP, NetWay4EWPN: NEMA4/4X, IP66 Rated enclosure for outdoor use. Dimensions (H x W x D approx.): 13.31" x 11.31" x 5.59" (338.1mm x 287.3mm x 142mm).
- NetWay4EWPX: NEMA4/4X, IP66 Rated enclosure for outdoor use. Accommodates four (4) 12VDC/4AH batteries (48V of backup). Dimensions (H x W x D approx.): 17.53" x 15.3" x 6.67" (445.3mm x 388.6mm x 169.4mm).
- NetWay4EX: Dimensions (H x W x D approx.): 13.5" x 13" x 3.25" (342.9mm x 330.2mm x 83mm).
Installation Instructions
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. All units should be installed by a trained service personnel.
Installation
NetWay4EB/NetWay4EPL:
- Mount board/backplane in the desired location/enclosure with hardware supplied.
- NetWay4EB: Connect 48/56VDC/120W max power source to terminal marked [+] and [-]. Note: For proper earth ground connections on NetWay4EB, fasten metal spacers (provided) to threaded studs at indicated board mounting holes (as shown in Fig. 1). This is recommended for better environmental immunity.
NetWay4EWPN/NetWay4EWP/NetWay4EWPX:
- Remove backplane from enclosure prior to drilling. Do not discard hardware. Note: Make sure that hardware will not interfere with components of the circuit board.
- Mark and drill desired inlets on the enclosure to facilitate wiring. Maximum NEMA type 4X rated fittings to be used are 0.5". Follow manufacturer's specifications for the appropriate size opening. Note: Inlets for conduit fittings should only be made on the bottom of the enclosure. To facilitate wire entry, utilize weather-tight NEMA rated connectors (supplied), bushings, and cable.
- Clean out the inside of enclosure before remounting circuit boards/backplane.
- Mounting NEMA4/4X rated enclosure (Enclosure Dimensions, pg. 10-12):
- Wall mount: Mount unit in desired location. Mark and drill holes to line up with the top and bottom hole of the enclosure flange. Secure enclosure with appropriate fasteners (e.g., screws and anchors; bolts and locking nuts, etc.) that are compatible with mounting surface and are of sufficient length/construction to ensure a secure mount (as shown in Fig. 6, pg. 9).
- Pole Mount: Refer to Fig. 7 - 11, pg. 9.
- Mount backplane in enclosure with hardware.
NetWay4EX:
- Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two (2) upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two (2) upper screws; level and secure. Mark the position of the lower two (2) holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the enclosure's upper keyholes over the two (2) upper screws. Install the two (2) lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 9). Secure enclosure to earth ground.
Power Connection
- NetWay4EWP, NetWay4EWPX, NetWay4EX, and NetWay4EPL: Before powering the unit, set the input voltage selection switch to the proper Input Voltage position (as shown in Fig. 3a, pg. 6). Units are factory set for 115VAC.
- Secure the cabinet to earth ground. Connect AC power from an overcurrent protective device circuit breaker (20A @ 115VAC, 60Hz, 16A @ 230VAC, 50/60Hz) to the terminals marked [L, N] on the power supply board (as shown in Fig. 3, pg. 6). Use 14AWG or larger for all power connections (Battery, DC output, AC input). Connect ground lug to earth or green branch wire (12AWG min.). Keep power-limited wiring separate from non power-limited wiring by utilizing separate knockouts/inlets. Minimum 0.25" spacing must be provided. CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.
- Battery Backup (if desired): Connect four (4) 12VDC batteries wired in series to terminals marked [BAT+] and [BAT-] (as shown in Fig. 4, pg. 8), carefully observing polarity. When use of stand-by batteries is desired, they must be lead acid or gel type. For outdoor battery backup, the battery enclosure must have sufficient ventilation. Use Altronix Vent2 kit. Note: When batteries are not used, a loss of AC will result in the loss of output voltage.
- Please ensure that the cover is secured with: Key lock and screws for NetWay4EX, latches and optional Altronix Lock1WP for NetWay4EWP, NetWay4EWPN and NetWay4EWPX.
Input/Data Connections
- Connect structured cables from port marked [Port 1] to [Port 4] on the NetWay unit to PoE compliant cameras/edge devices (as shown in Fig. 2, pg. 5).
- Insert SFP module into port marked [SFP], then connect cable to the SFP module on NetWay4EB to the corresponding input of an SFP switch (as shown in Fig. 2, pg. 5).
Recommended Altronix SFP Modules:
Altronix P1MM, P1SM10, P1AB2K and P1GCE are hot-pluggable SFP fiber transceiver modules and are readily usable with all Altronix Spectrum fiber optic equipment for 1Gb transmission rates.
- P1MM: For use with Multi-Mode Fiber for distances up to 550m.
- P1SM10: For use with Single-Mode Fiber for distances up to 10km.
- P1AB2K: For use with Single Strand Single-Mode Fiber for distances up to 2km.
- P1GCE: For use with CAT5e or better for distances up to 100m.
Recommended Altronix Power Sourcing Equipment:
- NetWaySP4P: Ethernet to Fiber Media Converter with Integral Power Supply/Charger. Four (4) 56VDC non power-limited outputs up to 120W max. full power per port (240W total power). Four (4) 1Gb SFP ports.
- NetWaySP4PX: Ethernet to Fiber Media Converter with Integral Power Supply/Charger. Four (4) 56VDC non power-limited outputs up to 120W max. full power per port (480W total power). Four (4) 1Gb SFP ports.
- NetWaySP4P2: Ethernet to Fiber Media Converter with Integral Power-Limited Power Supply/Charger. Four (4) 56VDC power-limited outputs up to 60W max. full power per port (240W total power). Four (4) 1Gb SFP ports.
- WayPoint562: High Current Outdoor Power Supply/Charger. 56VDC/120W output. Filtered and electronically regulated output. Short circuit and thermal overload protection.
- Vertiline563: EIA 19" 1U Rack Mountable Dual Independent Power Supply/Charger. 56VDC @ 3A each output. Filtered and electronically regulated output. Short circuit and thermal overload protection.
- PoE201: Power Supply/Charger Board. 56VDC/120W output. Filtered and electronically regulated output. Short circuit and thermal overload protection.
Technical Specifications
Parameter | Description | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Ports | Four (4) 10/100/1000 Mbps Ethernet ports rated at 30W each. IEEE 802.3af, 802.3at compliant. One (1) Gigabit SFP Port. | |||||||||||||||||||||
Input Power Requirements | NetWay4EWP/NetWay4EPL/NetWay4EWPX/NetWay4EX: 115VAC, 60Hz, 2.5A or 230VAC, 50/60Hz, 1.3A. NetWay4EB/NetWay4EWPN: 48-56V UL Listed ITE power supply. | |||||||||||||||||||||
Environmental Conditions | Operating Ambient Temperature:
| |||||||||||||||||||||
Storage Temperature: –30°C to 85°C (–22°F to 185°F). | ||||||||||||||||||||||
Relative Humidity: 85%, +/- 5% | ||||||||||||||||||||||
Operating Altitude: 304.8 to 2,000m. | ||||||||||||||||||||||
Weights (approx.) |
|
Typical Applications
NetWay4EB/NetWay4EWPN Application (Fig. 2)
This diagram illustrates a typical application for the NetWay4EB/NetWay4EWPN using a hybrid cable. IP devices (supporting 802.3af/802.3at) are connected to Ports 1-4. A master reset button and heartbeat/ALOS LEDs are visible. The unit connects to a 48-56V UL Listed ITE Power Supply and a Fiber Switch via a hybrid cable. The diagram emphasizes observing polarity for connections.
Power Distance Chart
The Power Distance Chart details maximum distances based on power requirements (15W to 120W) and power cabling gauge (12/2 or 16/2). For example, at 30W with 12/2 cabling, the maximum distance is 5,581 ft (1702m), while with 16/2 cabling, it is 2,207 ft (673m). These estimates are based on a 56VDC starting voltage with a 10-volt drop and account for IEEE 802.3at standards.
NetWay4EPL/NetWay4EWP/NetWay4EWPX/NetWay4EX Application (Fig. 3)
This diagram shows a typical application for the NetWay4EPL, NetWay4EWP, NetWay4EWPX, and NetWay4EX models. IP devices (supporting 802.3af/802.3at) are connected to Ports 1-4. The unit can be powered by 115VAC or 230VAC via an input voltage selection switch (Fig. 3a) and can also accommodate 48VDC to 56VDC stand-by batteries. Connections are made to a Fiber to Switch link. The diagram also highlights the master reset button and various LEDs.
Configuring Unit for Network Connection
VLANs
VLANs (Virtual Local Area Networks) segment networks to group devices, improve traffic flow, and enhance security. Planning VLAN setup is crucial for managing device access.
Configuring VLAN on the Altronix Netway4E Series Switch:
- Ensure your Laptop or PC is connected to a port that will be assigned to your first VLAN configuration. By default, the management portion is assigned to VLAN-1. CAUTION: Changing the default VLAN ID 1 should be done with caution and locally, as it will drop the current connection. Local access is then required for reconnection. Note: Only this VLAN network allows access to IP management.
- In the Network Section, click on the VLAN Tab.
- Click 'Add VLAN'.
- Enter a name for the VLAN.
- Enter a VLAN ID (e.g., 10, 20). Ensure this VLAN ID is associated with a VLAN setup on the main switch and that your programming device is on the same ID. Note: VLAN ID can range from 2-4094.
- Assign VLAN QoS (Quality of Service) priority (0 = Lowest, 7 = Highest).
- Select a Trunk port (Tagged Ports) for main network traffic connections to switches or WAPs.
- Select Access port(s) (Untagged Ports) associated with the VLAN, typically used for cameras. Ensure your laptop or PC is connected to one of these ports if programming locally.
- Save Configuration.
- Repeat steps 2-9 to add additional VLANs. If programming is lost, try moving your PC to a correct port on the main switch or perform a factory reset.
Advanced Port Settings:
- Unknown VID Packet Forwarding Configuration: By default, unknown VID packets are not forwarded. This can be configured to forward to a fixed set of ports.
- Configuration on Ingress Untagged Traffic: The default action for ingress UNTAGGED packets on Trunk Ports is not to drop them.
- Keep Tag on Egress: Select whether ACCESS Ports should retain the VLAN tag when sending egress packets. By default, tags are stripped.
- Preferred VLAN Forwarding: For ACCESS Ports belonging to multiple VLANs, select a preferred VLAN to forward UNTAGGED ingress packets. The last created VLAN is the default preferred VLAN.
Factory Reset Option
- Power down the unit and wait approximately 30 seconds for it to power down completely.
- Depress the Master Reset button on the NetWay4EB while reapplying power to the unit (refer to Fig. 3b, pg. 6 and Fig. 4, pg. 7).
- Continue holding the button until the LEDs on the board cycle through the startup sequence, then release the button.
- The unit will return to its original factory settings.
Typical VLAN Setup (Fig. 5)
This diagram illustrates a typical VLAN setup. Example VLAN ID 20 is shown for ports 3-4, and VLAN ID 10 for ports 1-2. The setup includes a Trunk port (carrying VLAN ID 10 and 20) connecting to a Host Switch via fiber. Ethernet ports can be used for VLAN Pass Thru, allowing connections to other switches (e.g., with VLAN ID 0 and/or 20).
Mounting
Wall Mount Installation
- Place the unit at the desired location and secure it with mounting screws (not included) (as shown in Fig. 6, pg. 9).
Pole Mounting Using Optional Pole Mount Kit PMK1 (NetWay4EWP) or PMK2 (NetWay4EWPX):
This installation should be performed by qualified service personnel. The product contains no serviceable parts. The PMK1 kit is intended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3, and WP4 enclosures. Brackets are designed for use with the included Wormgear Quick Release Straps.
- Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (as shown in Fig. 7, pg. 9).
- Once the desired height of the top Pole Mount bracket is achieved, tighten the straps by sliding the open end of the strap through the locking mechanism, then tighten the screw with a flat head screwdriver or 5/16" hex socket driver (as shown in Fig. 7, pg. 9 and Fig. 10, pg. 9).
- Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16" hex socket (as shown in Fig. 9, pg. 9).
- Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket (as shown in Fig. 7, pg. 9).
- Mount the enclosure onto the top bracket by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16" hex socket (as shown in Fig. 9, pg. 9).
- Tighten the straps of the bottom bracket by sliding the open end of the strap through the locking mechanism, then tighten the screw with a flat head screwdriver or 5/16" hex socket driver (as shown in Fig. 8, pg. 9).
- Clip excess straps.
Refer to Fig. 11 and Fig. 11a for pole diameter compatibility (2" to 8" round poles, 5" square poles).
Mechanical Drawings and Dimensions
NetWay4EX (H x W x D approx.: 13.5" x 13" x 3.25" / 342.9mm x 330.2mm x 82.6mm)
The front view shows a width of 13.0" (330.2mm) and height of 13.5" (342.9mm). The right side view shows a depth of 3.25" (82.6mm). Mounting holes are indicated on the front and side views, with specific dimensions provided for hole placement and enclosure features.
NetWay4EWP/NetWay4EWPN (H x W x D approx.: 13.31" x 11.31" x 5.59" / 338.1mm x 287.3mm x 142mm)
The front view dimensions are 11.31" (287.3mm) width and 13.31" (338.1mm) height. The right side view shows a depth of 5.59" (142mm). The front view with the cover removed details mounting hole locations (four 10-32 X 0.375" brass inserts) and latch mechanisms. The end view shows the depth and the piano hinge.
NetWay4EWPX (H x W x D approx.: 17.53" x 15.3" x 6.67" / 445.3mm x 388.6mm x 169.4mm)
The front view dimensions are 15.3" (388.6mm) width and 17.53" (445.3mm) height. The right side view shows a depth of 6.67" (169.4mm). The front view with the cover removed details mounting hole locations (four 10-32 X 0.250 brass inserts) and a stainless steel padlock latch. Section A-A provides details on the enclosure thickness and mounting plate. The end view shows the depth and wall mounting holes.
Company Information
Altronix is located at 140 58th Street, Brooklyn, New York 11220 USA. Contact them via phone at 718-567-8181 or fax at 718-567-9056. Their website is www.altronix.com, and email is info@altronix.com. The product comes with a Lifetime Warranty (H28Y).