Paul Neuhaus Q-AKUSTIK Smart Home LED Light
Fitting Instructions and Product Information
Product Overview
This document provides fitting instructions and technical details for the Paul Neuhaus Q-AKUSTIK Smart Home LED Light, model 6423-79.
Manufacturer: Paul Neuhaus GmbH
Address: Olakenweg 36, D-59457 Werl, Germany
Contact: +49(0)2922 9721 0, info@neuhaus-group.de
Technical Specifications
The luminaire is a modern, rectangular LED ceiling light with a natural wood frame.
Energy Efficiency: This product contains a light source of energy efficiency class <E>.
Specification | Details |
---|---|
Product Name | Q SMART HOME LIGHTS |
Model Number | 6423-79 |
LED Board | 1x LED-Board 24V DC/27W (not changeable) |
Power Consumption | 27W (LED Board), 35W (System) |
Luminous Flux | 3240 lm (at 27W), 1150 lm (at 35W) |
Mains Voltage | 230V / 50Hz ~ |
Lifespan | 25,000 hours |
Wireless Connectivity | 2.4 GHz, 10 dBm |
Color Temperature | Adjustable: 2,700 K - 5,000 K |
Switching Cycles | 15,000 times |
Warm-up Time | < 0.5 seconds |
Included Accessories:
- 1x IR Remote Control
- 4x AAA 1.5V Batteries
Installation Instructions
Important Safety Note: The luminaire must not come into contact with moisture. The luminaire should only be touched with gloves.
Step 1: Mounting the Fixture (as Ceiling Light)
This step involves attaching the fixture to the ceiling. It requires drilling holes of approximately 6mm diameter. Four mounting screws and four wall plugs are provided for secure installation.
Visual Description: The diagram shows the fixture being mounted to a flat surface, with mounting brackets being secured.
Step 2: Electrical Connection
Connect the mains power supply (230V/50Hz) to the luminaire. The connection points are typically labeled 'a' for Neutral (N) and 'b' for Live (L). Ensure all connections are made securely within the provided housing or junction box.
Visual Description: A diagram illustrates the wiring process, showing the connection of Live (L) and Neutral (N) wires from the mains supply to the luminaire's internal wiring terminals.
Remote Control and ZigBee Integration
Remote Control Operation
The luminaire is controlled via an included IR remote control. For detailed operation of the remote control, please refer to the separate Q-remote control manual.
ZigBee Network Integration (Reset Procedure)
To integrate the lamp into a ZigBee network, you must reset the lamp to its factory settings. Follow this procedure:
- Turn the lamp ON and OFF repeatedly.
- Perform the first 5 ON/OFF cycles with a pause of 5-10 seconds between each cycle.
- After the initial cycles, perform subsequent ON/OFF cycles with a pause of 1-2 seconds between each cycle.
Visual Description: The diagram shows a sequence of power cycles (ON/OFF) with specific time intervals indicated, leading to a reset state. The Q logo is shown, likely indicating the product's smart functionality.