FireAngel Carbon Monoxide Alarms

Models: FA3313, FA3322, FA3328 & FA3820

User Manual

Introduction

This user manual provides instructions for the FireAngel Carbon Monoxide (CO) alarms. The original English version of the manual is considered the authoritative text in case of discrepancies. The CO alarm is designed for continuous monitoring of CO levels and is suitable for residential use, including caravans, motor caravans, and boats. It should be installed by a competent person.

1. Positioning

Where to install the alarm: The CO alarm is suitable for hallways, landings, bedrooms, living rooms, dining rooms, and kitchens. Common sources of CO include boilers, generators, cookers, heaters, barbecues, fireplaces, and any fuel-burning appliances. Avoid installing in dusty, dirty, or greasy areas as this can affect sensor performance.

Placement within the room:

Additional alarms: Consider installing alarms in remote rooms where occupants spend significant time awake and may not hear alarms from other areas, and in all sleeping rooms. Place alarms in sleeping areas close to the occupants' breathing zone.

Caravans & Boats: Follow the same placement guidelines. An alarm is needed in any room with a fuel-burning appliance. If the caravan has a single living space, one alarm may suffice, but sleeping areas in separate rooms require an alarm.

Key positioning considerations: Do not place directly above heat or steam sources, and position 1-3 meters from the nearest edge of a potential CO source.

2. Installation

Alarm Activation: Pull the disabling tab to activate the alarm. For FA3328, attach the base plate. Wait up to 1 minute for the green LED to flash. Test the alarm by pressing the Test / button. Note: FA3322, FA3328, and FA3820 sound at a lower volume when the Test / button is pressed once; double-press for full volume.

Deactivation: Store the disabling tab for later use. To deactivate for travel or storage, reinsert the tab into the underside of the device (FA3313, FA3322, FA3820). Verify deactivation by pressing the Test / button.

Mounting:

FA3328 Anti-Tamper Lock: Activate by knocking out the plastic tab next to the lock symbol. To unlock, insert a small screwdriver into the hole at the bottom and slide the unit off the base plate.

3. CO Alarm Awareness

A loud alarm indicates potentially lethal CO levels. NEVER IGNORE THIS ALARM.

Immediate Actions:

  1. Check Residents: Look for symptoms of CO poisoning (headache, nausea, fatigue).
  2. Ventilate: Open doors and windows. Stop using and turn off fuel-burning appliances if possible.
  3. Evacuate: Leave the property immediately.
  4. Call for Help: Contact your fuel supplier's emergency number. Seek medical attention for anyone experiencing symptoms, mentioning suspected CO poisoning. Do not use appliances until checked by an expert.

Alarm Signal: A loud audible signal of 4 chirps (85 dB at 3m) and a flashing red light every second. The alarm responds faster at higher CO concentrations (e.g., within 3 minutes at 300 ppm).

CO Levels and Effects:

Early Warning: Models FA3322, FA3328, FA3820 provide an early warning for low CO levels (e.g., 10-20 ppm over 4 hours 35 mins). The pattern is 1 short chirp, 1 long chirp, and an amber flash every 25 seconds. Silence the early warning by pressing Test / for 12 hours.

Alarm Silence: Press Test / to silence the alarm for 5 minutes. The alarm cannot be silenced if CO levels exceed 150 ppm.

Alarm in Absence: If an alarm occurs while you are away, the device will flash red twice every 20 seconds after the CO level drops below 50 ppm, indicating a past dangerous CO level. The light flashes for 7 days unless cancelled.

Important Note: It can take up to 10 minutes for the sensor to clear and the alarm to stop after CO levels decrease. Do not re-enter until the alarm has stopped.

Vulnerable Individuals: This alarm protects against acute CO effects but may not provide sufficient protection for individuals at higher risk (due to age, pregnancy, or medical conditions). Consult a doctor if in doubt.

4. Maintenance

5. System Status Indicators

The alarm continuously checks sensor and circuitry accuracy. Faults and low battery levels are indicated by audible chirps and flashing amber LEDs/LCDs.

Important: If a fault or end-of-life condition is indicated, the alarm must be replaced immediately as it may not detect CO leaks.

6. Sleep Easy™ Silence Feature

If the low battery chirp occurs at night, press the Test / button to silence it for 8 hours. The amber LED will continue to flash. This feature can be used up to 10 times. For FA3313, replace batteries promptly; the feature is disabled for 30 days after replacement. For FA3322, FA3328, FA3820, replace the alarm.

Night Time Sensing (FA3322 & FA3328 only): These models automatically reduce LED brightness at night. If a low battery chirp was silenced during the day, the device reactivates the silence for another 8 hours at night.

7. FA3322 LCD Screen Indicators

The FA3322 model functions as both a CO and extreme temperature alarm. The LCD screen displays various indicators:

8. FA3328 'Sync-It' Data Download via NFC

Use the FireAngel app (download via QR code or visit www.fireangeltech.com/sync-it) and NFC technology to access alarm diagnostics on your phone or tablet by tapping it on the device.

Technical Specifications

Warnings: Alarms may not protect individuals at higher risk from CO. Not a substitute for smoke or gas detectors. Prolonged alarm exposure can damage hearing. LCD performance may be affected by temperatures below 0°C.

Technical Support: Contact details provided for inquiries.

Warranty

FireAngel Safety Technology Limited warrants the CO alarm against defects in materials and workmanship for 5 years from the date of purchase for normal residential use. The warranty covers replacement at FireAngel's discretion. It does not cover damage from accident, misuse, or lack of reasonable care. Replaceable batteries for FA3313 are not covered. Statutory rights are unaffected.

Disposal

Dispose of waste electrical products through WEEE recycling schemes. Do not dispose of with household waste. Deactivate models FA3322, FA3328, FA3820 before disposal. Remove batteries from FA3313 before disposal. Do not attempt to open or burn the unit.

Models: FA3313, FA3322, FA3328, FA3820, FA3820 Carbon Monoxide Alarms, Carbon Monoxide Alarms, Alarms

File Info : application/pdf, 2 Pages, 3.30MB

PDF preview unavailable. Download the PDF instead.

FireAngel-FA3820-User-Manual

References

Adobe InDesign 15.1 (Windows) Adobe PDF Library 15.0

Related Documents

Preview FireAngel CO Alarms FA3313, FA3322, FA3328, FA3820 User Manual
Comprehensive user manual for FireAngel Carbon Monoxide Alarms, covering installation, positioning, alarm awareness, maintenance, status indicators, and warranty information for models FA3313, FA3322, FA3328, and FA3820.
Preview FireAngel FA3313, FA3322, FA3328, FA3820 Carbon Monoxide Alarms - User Manual
Comprehensive user manual for FireAngel carbon monoxide alarms (models FA3313, FA3322, FA3328, FA3820), covering installation, positioning, alarm response, maintenance, system status, LCD indicators, technical specifications, warranty, and disposal.
Preview FireAngel FA3313, FA3322, FA3328, FA3820 Carbon Monoxide Alarms User Manual
Comprehensive user manual for FireAngel FA3313, FA3322, FA3328, and FA3820 carbon monoxide alarms, covering installation, positioning, operation, safety warnings, maintenance, and technical specifications.
Preview FireAngel Carbon Monoxide Alarm Icons Explained
A guide to understanding the various icons and indicators on your FireAngel Carbon Monoxide alarm, covering CO alarms, alarm memory, ventilation instructions, sleep mode, power status, and night-time sensing.
Preview FireAngel FA6813 Carbon Monoxide Alarm User Manual
Comprehensive user manual for the FireAngel FA6813 Carbon Monoxide Alarm, covering installation, operation, maintenance, troubleshooting, and safety information.
Preview FireAngel CO-9X Carbon Monoxide Alarm User Manual
User manual for the FireAngel CO-9X 7 Year Life Carbon Monoxide Poisonous Gas Alarm. Provides information on features, installation, operation, maintenance, and troubleshooting.
Preview FireAngel SCB10 Smoke & CO Alarm User Manual (GN5093R7)
User manual for the FireAngel SCB10 Smoke & CO Alarm, model GN5093R7. Provides installation, operation, and safety information for this combination smoke and carbon monoxide detector.
Preview FireAngel SCB10 Combination Smoke and Carbon Monoxide Alarm User Manual
User manual for the FireAngel SCB10, a combination smoke and carbon monoxide alarm, providing comprehensive instructions on installation, operation, maintenance, and safety for residential use.