Product Data Sheet
According to Delegated Regulation (EU) No. 626/2011
Supplier Information
Supplier/Brand Name: Cooper&Hunter
Model Identification
Model Identification Number: CH-S12FTXLA2-NG
Indoor Unit Identification Number: CH-S12FTXLA2-NG Indoor Unit
Outdoor Unit Identification Number: CH-S12FTXLA2-NG Outdoor Unit
Sound Power Levels
Sound power level in indoor spaces (cooling mode) | 57 dB |
Sound power level in indoor spaces (heating mode) | - dB |
Sound power level in outdoor spaces (cooling mode) | 63 dB |
Sound power level in outdoor spaces (heating mode) | - dB |
Refrigerant Information
Refrigerant Name: R32
Global Warming Potential of Refrigerant: 675
Refrigerant leakage contributes to climate change. A refrigerant with lower global warming potential (GWP) would have less impact on global warming per kilogram than a refrigerant with higher GWP. This appliance contains a refrigerant fluid with a GWP equal to 675. In a 100 year period, the impact on global warming from 1 kg of this refrigerant fluid is 675 times greater than from 1 kg of CO2. Never attempt to service the refrigerant circuit yourself or to dismantle the appliance; always ask a qualified technician to do so.
Cooling Mode
Seasonal energy efficiency ratio (SEER) | 7,1 |
Energy efficiency class | A+ |
Annual electricity consumption | 173 kWh/annum |
Rated power input | 3,5 kW |
Heating Mode
Average Season
Seasonal coefficient of performance (SCOP) (average season) | 4,1 |
Energy efficiency class (average season) | A+ |
Annual electricity consumption (average season) | 1 093 kWh/annum |
Rated power input (average season) | 3,2 kW |
Declared capacity (average season) | 3,0 kW |
Reserve heating capacity (average season) | 0,2 kW |
Warmer Season
Seasonal coefficient of performance (SCOP) (warmer season) | 5,2 |
Energy efficiency class (warmer season) | A+++ |
Annual electricity consumption (warmer season) | 888 kWh/annum |
Rated power input (warmer season) | 3,3 kW |
Declared capacity (warmer season) | 3,3 kW |
Reserve heating capacity (warmer season) | 0,0 kW |
Colder Season
Seasonal coefficient of performance (SCOP) (colder season) | 3,1 |
Energy efficiency class (colder season) | B |
Annual electricity consumption (colder season) | 3 048 kWh/annum |
Rated power input (colder season) | 4,5 kW |
Declared capacity (colder season) | 2,3 kW |
Reserve heating capacity (colder season) | 2,2 kW |
Market Placement
The model was placed on the Union market from 26/02/2024.
EPREL Registration
EPREL Registration Number: 1939218
Supplier Contact Information
Supplier: SIA Prof-Climate Sales Division (Authorized representative)
Customer Support:
- Name: Main
- Email: nemirov@cooperandhunter.com
- Address: Brivibas iela 109, LV-1001 Riga, Latvia
- Website: [Website not specified]
- Telephone: +1(289) 8093488