Cooper&Hunter CH-RHP09-230VO + CH-RSH09-12MCT
Technical Specifications and Features
Key Features
- Refrigerant Sensor
- Humidity Sensor
- GoldFin Anti-Corrosive Coating
- Multiple Fan Speeds
- Fresh Air Intake
- Omni-Directional Airflow
- Smart-Kit Built-in on Wall Thermostat
- Inverter technology
Indoor Unit Specifications (CH-RSH09-12MCT)
This section details the specifications for the indoor unit.
Parameter | Unit | Value | |
---|---|---|---|
Indoor Model | CH-RSH09-12MCT | ||
Power supply | V, Ph, Hz | 208-230V, 1Ph, 60Hz | |
Communication wiring | AWG | 14-4 | |
Cooling | Capacity | Btu/h | 9,000 (3,700~13,600) |
Input | W | 643 (200~1,150) | |
Rated current | A | 4.8 (1.6~5.1) | |
EER/EER2 | Btu/w | 14 | |
SEER/SEER2 | Btu/w | 22.6 | |
Dehumidification | L/H | 1.86 | |
Heating at 47 °F | Capacity | Btu/h | 10,000 (5,100~15,700) |
Input | W | 733 (285~1,330) | |
Rated current | A | 3.3 (1.5~5.9) | |
COP | W/W | 4 | |
HSPF4/HSPF2-4 | 12.1 | ||
HSPF5/HSPF2-5 | 9.3 | ||
Indoor fan motor | Qty | 1 | |
Input | W | 45 | |
RLA | A | 0.8 | |
Indoor air flow (Turbo/Hi/Med/Lo) (No duct) | CFM | 353.2 / 312 / 264.9 / 182.5 | |
ESP (range) | In.wg. | / | |
Indoor noise level (Hi/Med/Lo) | dB(A) | 40/37.5/26 | |
Indoor unit | Dimensions (WxDxH) | inch | 22.44 x 22.44 x 9.65 |
Packing (WxDxH) | inch | 28.15 x 25.20 x 11.61 | |
Net/Gross weight | lbs | 35.27/41.89 | |
Drainage water pipe diameter | inch | 1" | |
Refrigerant piping (Liquid side/Gas side) | inch | 1/4"/3/8" | |
Design pressure | PSIG | 550/340 | |
Controller | wire controller + remote controller available | ||
Room temperature | Cooling | F | 60~90 |
Heating | F | 32~86 |
Indoor Unit Dimensional Drawings: The indoor unit is shown in multiple views (front, side, top, bottom) with key dimensions indicated. These include the main body dimensions, drain pipe connection size (1 inch), and wiring connection port location. Specific measurements are provided in inches and millimeters for various components.
Outdoor Unit Specifications (CH-RHP09-230VO)
This section details the specifications for the outdoor unit.
Parameter | Unit | Value | |
---|---|---|---|
Outdoor Model | CH-RHP09-230VO | ||
Power supply | V, Ph, Hz | 208-230V, 1Ph, 60Hz | |
Min. circuit ampacity | A | 15 | |
Max. fuse | A | 15 | |
Compressor | Model | KTN110D42UFZ | |
Type | ROTARY | ||
Brand | GMCC | ||
Capacity | Btu/h | 11,820 | |
Input | W | 885 | |
Rated current (RLA) | A | 10.4 | |
Refrigerant oil | oz | VG74 11.8 | |
Outdoor fan motor | Qty | 1 | |
Input | W | 34 | |
RLA | A | 0.6 | |
Speed | r/min | 850/680/450 | |
Outdoor air flow (Max) | CFM | 1,471.5 | |
Outdoor noise level (Max) | dB(A) | 55 | |
Throttle type | EXV | ||
Outdoor unit | Dimensions (WxDxH) | inch | 31.69 x 12.99 x 21.81 |
Packing (WxDxH) | inch | 36.02 x 14.57 x 24.21 | |
Net/Gross weight | inch | 72.75/78.70 | |
Refrigerant | Type | R454B | |
Precharge | ft | 25 | |
Additional charge for 1/4 inch liquid pipe | oz | 0.16 | |
Additional charge for 3/8 inch liquid pipe | oz | / | |
Refrigerant piping | Liquid side/Gas side | inch | 1/4"/3/8" |
Max. pipe length | ft | 82 | |
Max. difference in level | ft | 49.2 | |
Ambient temperature | Cooling | F | -22 ~ 122 |
Heating | F | -22~75 |
Outdoor Unit Dimensional Drawings: The outdoor unit is depicted in front, side, and top views, illustrating its overall dimensions and key connection points. Measurements are provided for width, depth, and height, as well as for refrigerant pipe sizes (1/4 inch liquid, 3/8 inch gas) and drain connections.
Cooper&Hunter products are subject to continuous improvements. Cooper&Hunter reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations. Actual unit design may differ from images shown in this submittal sheet.