Introduction
Thank you for purchasing a Mark-10 Force Test Stand. These stands are designed for tension and compression force measurement applications and are crucial components in force testing systems. This user's guide covers setup, safety, and operation instructions, along with dimensions and specifications.
For additional support or inquiries, Mark-10's technical support and engineering teams are available to assist.
Key Features and Components
The ESM Series Force Test Stands are ruggedly built for reliable service in laboratory and industrial environments. Key components include:
- Control Panel
- Crosshead
- Load Cell / Force Sensor / Force Gauge
- Grips and Fixtures
- Base Plate and Base
- Emergency Stop Button
Users should be fully trained in appropriate operation and safety procedures before using the test stands.
Safety Precautions
General Safety:
- Ensure the test stand is placed on a sturdy, clean, and level work area.
- Never operate the test stand if there is visible damage to the power cord or the unit itself.
- Keep the test stand away from water and electrically conductive liquids.
- Ensure the electrical outlet has a proper earth ground connection.
- Servicing should only be performed by trained technicians. Disconnect power before removing covers.
Operational Safety:
- Conduct a risk assessment before testing, especially with brittle samples.
- Wear appropriate eye and face protection.
- Be aware of potential energy in test samples.
- Keep clear of moving parts. Avoid loose clothing and secure long hair.
- A Crush Hazard warning is present on the base of the stand.
- Use machine guards where appropriate for hazardous situations.
- Turn off power when the test stand is not in use.
Getting Started
Setup involves:
- Moving the stand into position.
- Mounting the control panel.
- Connecting power and any necessary accessories.
- Installing the load cell or force gauge.
- Installing the interface cable if applicable.
Refer to the relevant sections within this guide for detailed step-by-step instructions.
Operation Modes
The test stands feature three primary modes:
- Operating Mode: For starting and stopping testing sequences.
- Test Function Setup: For configuring test parameters like speed, cycles, and limits.
- Function Activation: To manage purchased functions and utilize demo mode features.
The test stands are shipped in Demo Mode, activating all functions for 160 hours of operation.
Resources
For further information, including USB driver installation and ASCII commands for PC control, please visit the Mark-10 website at www.mark-10.com.