Sygonix RFID/Fingerprint Access System

Operating Instructions

Item no. 2380476

Intended use

This product is designed to prevent unauthorized access to doors (e.g., in an office) and to activate/disable alarm systems. Control can be exercised via suitable transponders or fingerprints. Holding a paired user transponder in front of the reading surface or placing a stored finger on the fingerprint sensor activates a potential-free relay changeover contact. This can be used, for example, to control a door opener or an alarm system.

The product is intended for vertical installation on a wall and is suitable for indoor and outdoor use (IP 66). Do not rebuild and/or modify this product. Using the product for purposes other than those described above may damage the product. Read the operating instructions carefully and store them in a safe place. Only make this product available to third parties together with its operating instructions.

This product complies with statutory, national and European regulations. All company and product names contained herein are trademarks of their respective owners. All rights reserved.

Delivery content

Up-to-date operating instructions

Download the latest operating instructions at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website.

Description of symbols

⚠️ The symbol with an exclamation mark in a triangle is used to highlight important information in these operating instructions. Always read this information carefully.

➡️ The arrow symbol indicates special information and tips on how to use the product.

Safety information

⚠️ Read the operating instructions carefully and observe in particular the safety instructions. If you do not follow the safety information and information on proper handling in these operating instructions, Sygonix assumes no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.

Installation and connection

Use suitable screws and, if necessary, dowels to mount the mounting plate with the module on the wall (see figure on the right) depending on the type of wall.

The included mounting frame can be pre-installed depending on the substrate and installation position, and the access system should then be screwed tight. Suitable screws and, if necessary, dowels should be used depending on the substrate. A hole for the connecting cable must be drilled before fastening.

⚠️ Ensure that no cables or wires are damaged when drilling holes or tightening screws.

Wiring should be carried out according to the following examples. Ensure that there is suitable insulation (e.g. heat shrink tubing).

A protective diode is included for connecting a door opener. It protects the electronics from damage caused by voltage surges. Ensure the correct polarity, as shown in the following connection examples (when connected, the ring on the protective diode must face the positive pole/+).

⚠️ Never switch the mains voltage via the potential-free changeover contact! There is a risk of fatal electric shock! Observe the permissible contact rating; see "Technical data" chapter.

Use suitable cables with different colours. Note the colours and store this information together with these instructions. When connecting the cables, pay attention to the correct polarity (plus/+ and minus/-).

Connection to conventional voltage/power supply:

When a conventional power supply unit should be used, observe the wiring diagram on the right.

A) "Fail Secure" door opener: Releases the locking latch only when its operating voltage is applied (common design for front doors).

B) "Fail-safe" door opener: releases the locking latch only when the operating voltage is missing (uncommon design, e.g. used for escape route doors, which can be opened in the event of a power outage).

  1. Access system
  2. Door opener button
  3. Power adapter
  4. "Fail-Secure" door openers
  5. "Fail-Safe" door openers

The included diode must be connected correctly near the door opener to protect the access system from voltage surges.

Connecting to alarm system

Observe the operating instructions for the alarm system used. The access system relay switches when a valid transponder is recognised or when a stored finger is placed on the sensor. The alarm system can thus be enabled or disabled.

Operation

Switch on the operating voltage after installation and connection. The access system LED lights up red. This indicates that the access system is in standby mode. You can now start programming.

Programming

The included transponder is normally paired as a master transponder and can be used to pair/save or delete user transponders and user fingerprints. In the section below you will find instructions on how to pair a master fingerprint.

a) Pairing a new master transponder and/or master fingerprint

A new master transponder can be paired if the currently used master transponder is lost or defective. There can be only one master transponder for security reasons (if a lost master transponder "shows up", it will no longer be recognised).

You can save a master fingerprint or a master transponder or both.

b) Saving a user transponder/fingerprint

c) Deleting the user transponder

d) Setting relay switching time

By default, the relay is activated for 5 seconds when a paired user transponder/fingerprint is read. This time can be adjusted from 1 to 99 seconds and toggle mode (relay switches upon each reading) can be selected.

Switching to toggle mode

Setting the relay switching time

e) Resetting to factory defaults

Care and cleaning

Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may damage the casing or cause the product to malfunction.

Use a dry, lint-free cloth to clean the product.

Disposal

Electronic devices are recyclable waste and must not be placed in household waste. At the end of its service life, dispose of the product in accordance with applicable regulatory guidelines. You thus fulfil your statutory obligations and contribute to environmental protection.

Declaration of Conformity (DOC)

Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declares that this product conforms to Directive 2014/53/EU.

Click on the following link to read the full text of the EU Declaration of Conformity: www.conrad.com/downloads

Enter the product's order number in the search field; you can then download the EU Declaration of Conformity in the available languages.

Specifications

Connections and controls

  1. Opening for wall mounting
  2. LED
  3. RFID/fingerprint sensor with LED ring

Connecting cable:

ColourInscriptionFunction
Red12-18 V/DCOperating voltage 12 - 18 V/DC
BlackGNDGND/ground
YellowOPENDoor opener button
GreenNCNC (normally closed) contact of relay
BrownCOMCOM (centre contact) contact of relay
WhiteNONO (normally open) contact of relay
Models: 2380476, Rfid Fingerprint Access System

File Info : application/pdf, 2 Pages, 498.24KB

PDF preview unavailable. Download the PDF instead.

hasznalati-utmutato-2380476-besuellyesztheto-ujjlenyomatrfid-belepteto-12-vdc-18-vdc-ip66-sygonix-sy-4760952 Adobe PDF Library 9.9 Adobe InDesign CS5 (7.0)

Related Documents

Preview Sygonix Wi-Fi/RFID/Fingerprint Access System Software Instructions & Guide
Comprehensive software instructions for the Sygonix Wi-Fi, RFID, and Fingerprint Access System (Item No. 3060831), covering setup, member management, authentication, and unlinking.
Preview Sygonix RFID/Codeschloss IP66 Bedienungsanleitung
Bedienungsanleitung für das Sygonix RFID/Codeschloss IP66, inklusive Funktionen, Montage, Anschluss und Programmierung.
Preview Sygonix RFID/Code Lock IP66 Programming Codes Overview
A comprehensive guide to the programming codes for the Sygonix RFID/Code Lock IP66, detailing functions, input formats, and default settings for various operations.
Preview Sygonix RFID/Codeslot IP66 Gebruiksaanwijzing
Handleiding voor het Sygonix RFID/Codeslot IP66, inclusief installatie, programmering en veiligheidsinstructies.
Preview Sygonix RFID/Code Lock IP66 Operating Instructions
Comprehensive operating instructions for the Sygonix RFID/Code Lock IP66, detailing installation, programming, features, and safety guidelines for secure access control.
Preview Sygonix RFID/Codeslot IP66 Programming Codes Overview
This document provides an overview of the programming codes for the Sygonix RFID/Codeslot IP66, including functions, input methods, and default settings.
Preview Sygonix RFID/Code Lock IP66 Programming Codes Overview
This document provides an overview of the programming codes for the Sygonix RFID/Code Lock IP66, detailing configuration functions, input formats, and default parameters.
Preview Sygonix RFID/Code Lock IP66 Operating Instructions
Comprehensive operating instructions for the Sygonix RFID/Code Lock IP66, detailing installation, programming, features, and safety guidelines.