VEVOR LED Panel Lights Installation and Safety Guide
This document provides essential instructions for the installation, operation, and safety of VEVOR LED Panel Lights. Please read all instructions carefully before operating the product. VEVOR reserves the right to interpret its user manual.
Note: The appearance of the product may vary. This manual is for reference only.
Product Overview
VEVOR LED Panel Lights offer selectable wattage and color temperature (CCT) options, providing versatile lighting solutions for various applications. They are designed for efficient and reliable performance.
Specifications
Model | Input Power | Size (mm) |
---|---|---|
GT-MB D24-1 | AC 120V 60 Hz | 1215 x 600 x 35 |
GT-MB D24-2 | AC 120V 60 Hz | 600 x 600 x 35 |
GT-MB D22-4 | AC 120V 60 Hz | 1215 x 305 x 35 |
GT-MB D14-2 | AC 120V 60 Hz | 1215 x 305 x 35 |
Key Features: Wattage and CCT Selection
These VEVOR LED Panel Lights feature integrated DIP switches allowing users to select the desired wattage and color temperature (CCT) before installation. The specific options available vary by model.
Model-Specific Wattage and CCT Options:
- GT-MB D24-1: Selectable Wattage (30W/40W/50W), Selectable CCT (4000K/5000K/6000K)
- GT-MB D24-2: Selectable Wattage (25W/30W/40W), Selectable CCT (3000K/4000K/5000K)
- GT-MB D22-4: Selectable Wattage (25W/30W/40W), Selectable CCT (3000K/4000K/5000K)
- GT-MB D14-2: Selectable Wattage (30W/40W/50W), Selectable CCT (3000K/4000K/5000K)
Switch Configuration Diagram Description
The fixture is equipped with two DIP switches. The right switch controls the wattage, typically offering three settings that increase power from left to right. The left switch controls the color temperature, also with three settings that change the temperature from left to right. Refer to the product's specific markings for exact settings.
Important Safety Precautions
Please read the following safety information carefully before installation and use:
- Always turn off the main power supply before installation or maintenance.
- This equipment is intended for installation by qualified personnel only, in accordance with applicable electrical codes and local building regulations.
- Incorrect installation can cause fire or electrical hazards.
- Ensure the electrical power to the circuit has been disconnected before installing this electrical system.
- Review diagrams thoroughly and disconnect all electrical power before installation to avoid electrical shock.
- Do not mount near flammable materials or electric heaters.
- Do not allow the power cord to touch hot surfaces.
- The fixture is for indoor or dry location use only. Do not use in outdoor locations.
- The fixture should be installed or maintained by a qualified electrician or a person familiar with the fixtures.
- Always use the lamp from the original package.
- Before using the lamp, check if it is damaged during transport. If damaged, do not use or install the lamp.
- Do not disassemble or repair the lamp yourself.
- To reduce the risk of fire, electric shock, or injury: Turn off the circuit breaker before installing this fixture.
- This product should be installed by someone familiar with its construction and operation and the associated hazards.
- Safety glasses and gloves are recommended.
- Comply with all relevant regional and local laws or regulations.
- Proper grounding is required to ensure safety.
- Keep the fixture away from corrosive substances.
- Do not use where directly exposed to water.
- Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
- This product is not compatible with 3rd party sensors or dimmers unless specified.
Radio Frequency Interference: This product may cause interference with radio communications if not installed and used as instructed. If interference occurs, try repositioning the antenna, increasing the distance between the product and receiver, connecting the product to a different circuit, or consulting a dealer or experienced technician.
Wiring Instructions
Follow these steps for proper wiring:
- Open the junction box cover.
- Remove the round knockout and connect the conduit or cable to the wiring box using appropriate connectors.
- Connect the AC input: Connect the neutral wire to AC-N, the line wire to AC-L, and the ground wire to the green wire. It is recommended to use 16GA pigtails from the terminal block to the respective power supply wires.
- For 0-10V dimmable wiring: Connect the low-voltage leads from the 0-10V dimming device to the respective DIM+ and DIM- terminals on the block.
Note: A 0-10V dimmer is required for dimming functionality. The universal voltage driver allows operation at 120V 60Hz. 0-10V control wires must be rated for 300V minimum.
Wire Gauge Note: If using a wire larger than 16 AWG for AC neutral or line connections, a pig-tail or jumper wire must be added in the ACL and ACN terminals.
Installation Instructions
Choose the appropriate installation method:
Recessed Mounting
Follow these steps for recessed installation:
- Configure Switches: Before installation, set the desired wattage and color temperature using the two DIP switches located on the fixture (refer to the "Switch Configuration Diagram Description" above).
- Prepare Fixture: Rotate the mounting clips 90° counter-clockwise to secure the panel.
- Connect Driver: Connect the LED driver to the power source.
- Insert Panel: Insert the LED panel into the T-bar ceiling grid with the front facing down. Align the panel with the edge of the T-bar.
- Secure Panel: Adjust the panel to the correct position and ensure it is securely fitted.
- Mounting Hook: The "Mounting HOOK" (if present) is for positioning only or equivalent.
Metal Rope Suspension Mounting
Follow these steps for suspension mounting:
- Configure Switches: Adjust the wattage and color temperature using the two DIP switches as described previously.
- Attach Rings: The lamp body is equipped with four metal rings for attaching the suspension ropes.
- Thread Ropes: Thread the wire rope through a fixed metal ring on the fixture body and screw the metal ring clockwise into the fixture. Repeat for all four rings.
- Install Ceiling Fixings: Install four fixed metal cable rings at the same position on the ceiling. This may require professional tools for impact power stations. Ensure safety during this step.
- Connect Ropes to Ceiling: Thread the four wire ropes into the fixed rings on the ceiling.
- Adjust Height: Adjust the suspension ropes to the appropriate height.
- Tighten Fixings: Tighten the fixed metal rings clockwise to secure the suspension.