GENERAL FEATURES
- High-pressure protection
- Variable speed INVERTER-driven compressor
- Rated for 2,000 hours spraying time per ASTM B117 Standard
- Quiet outdoor unit operation as low as 52 dB(A)
- Prolonged heating over an extended duration
- Fan motor overheating/voltage protection
- Compressor thermal protection
- Compressor overcurrent detection
- Compact, small chassis
- Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life
Specifications
Unit Type | System | Cooling at 95°F¹ (Non-Ducted // Mixed // Ducted) | Heating at 47°F² (Non-Ducted // Mixed // Ducted) | Heating at 17°F³ (Non-Ducted // Mixed // Ducted) | Heating at 5°F⁴ (Non-Ducted // Mixed // Ducted) | Efficiency (Non-Ducted // Mixed // Ducted) | Electrical |
---|---|---|---|---|---|---|---|
Maximum Capacity | Btu/h | 20,000 // 21,000 // 22,000 | 25,700 // 25,750 // 25,800 | 16,600 // 16,200 // 15,800 | 13,700 // 12,600 // 11,800 | ||
Rated Capacity | Btu/h | 18,000 // 19,000 // 20,000 | 24,000 // 22,000 // 23,000 | 16,500 // 15,000 // 13,500 | SEER2¹: 20 // 18 // 16 EER2¹: 13 // 11.50 // 10 HSPF2 (IV)²: 10 // 9.55 // 9.10 |
Electrical Power Requirements: V AC / V AC, Ø, Hz: 208 / 230, 1, 60 | |
Minimum Capacity | Btu/h | 5,700 // 5,700 // 5,700 | 7,400 // 7,400 // 7,400 | COP at 47°F²: 3.92 // 3.76 // 3.64 COP at 17°F³: 2.60 // 2.48 // 2.36 COP at 5°F⁴: 2.23 // 2.04 // 1.88 |
Guaranteed Voltage Range: V AC: 198 - 253 | ||
Maximum Power Input | W | 2,245 // 2,257 // 2,270 | 2,465 // 2,498 // 2,530 | 1,860 // 1,910 // 1,960 | 1,800 // 1,815 // 1,830 | Voltage: Indoor - Outdoor, S1-S2: V AC: 208/230 | |
Rated Power Input | W | 1,384 // 1,692 // 2,000 | 1,794 // 1,783 // 1,771 | 1,690 // 1,590 // 1,490 | Voltage: Indoor - Outdoor, S2-S3: V DC: 24 | ||
Power Factor (208V) | % | 0.99 // 0.99 // 0.99 | 0.99 // 0.99 // 0.99 | Recommended Wire Size (Indoor - Outdoor): AWG: 14 | |||
Power Factor (230V) | % | 0.99 // 0.99 // 0.99 | 0.99 // 0.99 // 0.99 | Short-circuit Current Rating (SCCR): kA: 5 | |||
ENERGY STAR® Certified: Yes // Yes // No | Recommended Fuse/Breaker Size: A: 20 | ||||||
MCA: A: 21.7 | |||||||
MOCP: A: 38 |
NOTES
¹Cooling at 95°F (Indoor: 80°F DB, 67°F WB // Outdoor: 95°F DB, 75°F WB)
²Heating at 47°F (Indoor: 70°F DB, 60°F WB // Outdoor: 47°F DB, 43°F WB)
³Heating at 17°F (Indoor: 70°F DB, 60°F WB // Outdoor: 17°F DB, 15°F WB)
⁴Heating at 5°F (Indoor: 70°F DB, 60°F WB // Outdoor: 5°F DB, 4°F WB)
Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer to Multi-zone Outdoor Unit Operational Performance.
For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance.
Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time.
* Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
** Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures): System cuts out in heating mode and automatically restarts at these temperatures.
Detailed Specifications
Specification | Unit | System |
---|---|---|
Fan Motor Full Load Amperage | A | 1.77 |
Fan Motor Output | W | 64 |
Defrost Method | Reverse Cycle | |
Blue Fin Heat Exchanger Coating | Yes | |
Airflow Rate Cooling/Heating | CFM | 1,324 / 1,451 |
Sound Pressure Level, Cooling¹ | dB (A) | 51 |
Sound Pressure Level, Heating² | dB (A) | 55 |
Compressor Type | Twin Rotary | |
Compressor Model | SRB140FQHM1T | |
Compressor Oil Type // Charge | Type // oz | RM68EH // 20.3 |
External Finish Color | Munsell 3.0Y 7.8/1.1 | |
Base Pan Heater | Optional | |
Unit Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 33-1/16 x 13 x 27-15/16 [840 x 330 x 710] |
Package Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 38-31/32 x 17-5/16 x 34-21/32 [990 x 440 x 880] |
Unit Weight | lbs [kg] | 119 [54] |
Package Weight | lbs [kg] | 137 [62] |
Cooling Intake Air Temp (Maximum / Minimum) | °FDB | 115 / 14 |
ODU Operating Temp. Range | °FDB | 10 / 14 |
Cooling Thermal Lock-out / Re-start Temperatures | °FDB, °FWB / °FDB, °FWB | 75, 65 / 6, 5 |
Heating Intake Air Temp [Maximum / Minimum] | °FDB | -4 / 5 |
Heating Thermal Lock-out / Re-start Temperatures** | °FDB | -4 / 5 |
Refrigerant Type | R454B | |
Pre-Charged Refrigerant Amount | lbs, oz | 4, 7 |
Maximum Pre-Charged Piping Length | ft | 164 |
Minimum Number of Connected IDU | 2 | |
Maximum Number of Connected IDU | 2 | |
Minimum Connected Capacity | Btu/h | 12,000 |
Maximum connected capacity | Btu/h | 24,000 |
Liquid Pipe Size O.D. (Flared) | inch | A: 1/4 B: 1/4 |
Gas Pipe Size O.D. (Flared) | inch | A: 3/8 B: 3/8 |
Total Piping Length | ft [m] | 164 [50] |
Farthest Piping Length | ft [m] | 82 [25] |
Maximum Height Difference*B, ODU above IDU | ft [m] | 32 [10] |
Maximum Height Difference*B, ODU below IDU | ft [m] | 49 [15] |
Maximum Number of Bends for IDU | 50 |
OUTDOOR UNIT ACCESSORIES
Item | Part Number |
---|---|
18 Single Fan Stand | QSMS1801M |
24 Single Fan Stand | QSMS2401M |
Condenser Wall Bracket | QSWB2000M-1 |
Condenser Wall Bracket - Stainless Steel Finish | QSWBSS |
Outdoor Unit 3-14 inch Mounting Base Pair - Plastic | DSD-400P |
Outdoor Unit Stand 12 High | QSMS1201M |
Drain Socket | MAC-811DS |
Optional Defrost Heater | PAC-646BH-E |
Refrigeration Ball Valve - 1/2 | BV12FFSI2 |
Refrigeration Ball Valve - 1/4 | BV14FFSI2 |
Refrigeration Ball Valve - 3/8 | BV38FFSI2 |
Refrigeration Ball Valve - 5/8 | BV58FFSI2 |
14 Gauge 4 wire Armored MiniSplit Cable 250 ft roll | SW144-250 |
14 Gauge 4 wire Armored MiniSplit Cable 50 ft roll | SW144-50 |
14 Gauge 4 wire MiniSplit Cable 250 ft roll | S144-250 |
14 Gauge 4 wire MiniSplit Cable 50 ft roll | S144-50 |
16 Gauge 4 wire Armored MiniSplit Cable 250 ft roll | SW164-250 |
16 Gauge 4 wire Armored MiniSplit Cable 50 ft roll | SW164-50 |
16 Gauge 4 wire MiniSplit Cable 250 ft roll | S164-250 |
16 Gauge 4 wire MiniSplit Cable 50 ft roll | S164-50 |
M-NET Interface for MXZ | PAC-IF01MNT-E |
Condensing Unit Mounting Pad 16 x 36 x 3 | ULTRILITE1 |
Muffler | MAC-001MF-E |
Maintenance Tool Interface | PAC-USCMS-MN-1 |
Adaptor 1/2 x 3/8 | PAC-SK88RJ-E |
Adaptor 1/2 x 5/8 | PAC-SK89RJ-E |
Adaptor 1/4 x 3/8 | PAC-493PI |
Adaptor 3/8 x 1/2 | ADP3812 |
Adaptor 3/8 x 5/8 | PAC-SK90RJ-E |
Air Outlet Guide | MAC-856SG |
Snow/Rain Diverter | SRD-4 |
Hail Guards | HG-A8 |
OUTDOOR UNIT DIMENSIONS
The MXZ-2D20NL outdoor unit has a compact design. The following describes its dimensions and installation requirements based on the provided diagrams:
Front View
The unit features an air inlet on the left side and an air outlet on the front. Key dimensions include a width of approximately 33-1/16 inches (840 mm), a depth of 13 inches (330 mm), and a height of 27-15/16 inches (710 mm). It includes a handle, a drain hole (3-5/16 inches from the side), and connecting wire holes.
Side View
The side view shows the depth of the unit and the fan grille. The overall dimensions are consistent with the front view, with a depth of 13 inches (330 mm).
Top View
The top view details the width and depth of the unit, showing the fan grille area and overall casing.
Installation Space Requirements
Proper installation requires specific clearances:
- 1. FREE SPACE: Minimum 19-11/16 inches (500 mm) clearance is required in front of the unit.
- 2. SERVICE SPACE: Minimum clearances are required on the sides and rear for maintenance and airflow. Specific requirements include: 14-3/16 inches (360 mm) on one side, 11-25/32 inches (300 mm) on the other, 3-15/16 inches (100 mm) or more on the rear, 7-7/8 inches (200 mm) or more on the top, and 13-25/32 inches (350 mm) or more for service access.
Pipe Connections
The unit has distinct connections for liquid and gas lines:
- LIQ Unit A: 1/4" (Ø6.35) FLARE
- GAS Unit A: 3/8" (Ø9.52) FLARE
- LIQ Unit B: 1/4" (Ø6.35) FLARE
- GAS Unit B: 3/8" (Ø9.52) FLARE
Foundation bolt holes are oval, sized for M8 bolts.