Introduction
Human Touch has been a leader in massage products for decades, blending advanced technology with the ancient healing art of massage. Human Touch Massage Systems are designed to help achieve balance between physical and mental well-being. For more information, visit humantouch.com or call 800-355-2762.
The Human Touch HT-410 massage chair incorporates patented Human Touch Massage System™ technology, emulating techniques used by massage and chiropractic professionals. It aims to provide a bridge between technology and therapeutic massage for a balanced life.
Important Safety Instructions
When using electrical appliances, basic precautions must be followed:
- Always unplug the product after use and before cleaning.
- Do not put hands or fingers near the massage mechanism or rollers while in operation.
- If the supply cord is damaged, it must be replaced by the manufacturer or a qualified service agent.
- Never leave the appliance unattended when plugged in.
- Do not operate under blankets or pillows to avoid overheating.
- Close supervision is necessary when used by, on, or near children, invalids, or disabled persons.
- Use only for its intended purpose as described in the manual.
- Never operate if the cord or plug is damaged, or if the product is not working properly, has been dropped, or submerged in water. Return to a service center.
- Do not carry by the supply cord or use the cord as a handle.
- Keep the power cord away from heated surfaces.
- Keep air openings free of lint, hair, and other obstructions.
- Never drop or insert objects into any opening.
- Do not use outdoors.
- Do not operate where aerosol products are used or oxygen is administered.
- To disconnect, turn all controls to OFF and remove the plug from the outlet.
- Do not massage swollen, inflamed, or erupted skin areas.
- Do not use on unexplained calf pain.
- Do not use on damp floors or when body parts contact plumbing or similar grounds.
- Connect only to a properly grounded outlet.
- Do not use if abnormal noise is heard.
- Do not stand on or in the appliance; use only while seated.
- This appliance is not intended for use by persons with reduced physical, sensory, or mental capabilities, or lack of experience, unless supervised. Children should be supervised to ensure they do not play with the appliance.
Safety Precautions:
- Wear comfortable clothing.
- Use the product in a relaxed position; never force body parts into the backrest area while rollers are moving.
- If abnormal discomfort occurs, turn off the power immediately and consult a physician.
- Do not sit on the controller.
- Do not pull on the AC cord.
- Check for proper operation after storage.
- Ensure no obstacles are behind the product and sufficient space is available for reclining.
Grounding Instructions:
This product must be grounded. If it malfunctions, grounding provides a path of least resistance for electrical current to reduce the risk of electric shock. The product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate, properly installed, and grounded outlet according to local codes.
DANGER: Improper connection of the grounding conductor can result in electric shock. Consult a qualified electrician if unsure about grounding. Do not modify the plug; have a proper outlet installed if needed.
The product uses a standard 120-volt circuit with a grounding plug (illustrated as sketch A). A temporary adapter (sketches B and C) may be used to connect to a 2-pole receptacle if a grounded outlet is unavailable, but it should only be used until a qualified electrician can install a proper grounded outlet. The adapter's green tab must be connected to a permanent ground, such as a grounded outlet box cover, secured by a metal screw.
Grounding Methods:
- (A) Grounded Outlet: Shows a standard three-prong outlet.
- (B) Adapter Use: Shows a three-prong plug connected via an adapter to a two-prong outlet, with the adapter's grounding tab secured to the outlet box with a metal screw.
- (C) Adapter Detail: Close-up of the adapter showing the grounding tab.
Temporary adapters are not permitted in Canada.
Assembly Instructions
Your Human Touch massage chair requires simple assembly with no tools needed. Attach the backrest pad, seat pad, and head pillow.
Unpack the Box:
Illustrations show the main chair, seat pad, backrest pad, and head pillow.
1. Unfold the Chair:
Remove all packaging materials. Pull up on the backrest to unfold the chair to an upright position. The backrest locks automatically.
2. Attach the Backrest Pad:
Attach the top flap of the backrest pad to the top of the backrest. Smooth the bottom flaps under the backrest. Attach side flaps to the sides of the backrest. All flaps use hook-and-loop fasteners.
3. Attach the Seat Pad:
Stand on the right side of the chair. Pull the footrest control lever to extend the footrest horizontally. Pull the rotation release handle (on the right side of the footrest) and rotate the footrest away from the chair to a vertical position. Attach the seat pad to the seat using hook-and-loop fasteners. Wrap the front flap of the seat pad around the chair frame and attach it to the top of the chair frame using hook-and-loop fasteners.
4. Attach the Head Pillow:
Flip the flap on the back of the backrest pad up and over the chair. Attach the head pillow to the flap using hook-and-loop fasteners. Adjust the head pillow height for comfort.
Operation Instructions
Using your Human Touch massage chair is easy. Sit back, adjust the backrest and foot/calf massager, and enjoy a variety of massage techniques for relaxation.
1. Power On:
Plug the power cord into a grounded power source. Turn the master power switch (located on the bottom center of the backrest) to 'On'.
2. Adjust the Footrest Height:
While seated, pull the footrest control lever (right side of chair) to raise the footrest to a comfortable height. Release the lever.
3. Adjust the Backrest:
Use the remote control's Recline and Incline settings to adjust the backrest angle for maximum comfort.
A slight pause may occur when changing backrest or foot/calf massager direction as gears shift; this is normal.
To collapse the chair for moving: Press the backrest release lever (on the back of the chair, under the rear right seat corner) and push the backrest down onto the seat.
For a Foot or Calf Massage:
1. Deploy the Foot and Calf Massager:
Pull the footrest rotation release handle (right side). For a calf massage, rotate the footrest away from the chair until it clicks into position with the massager facing up. Do not force past the click. For a foot massage, rotate just until the massager faces up; do not let it click into place, allowing it to move freely.
2. Insert Your Feet or Calves:
Place your feet or calves into the deployed massager.
Note: Do not stand or sit on the foot and calf massager.
For easier exit: Retract the footrest and return the backrest to a full upright position before getting out. Ensure the area behind/under the footrest is clear before retracting. Use the footrest lever to retract and the Power Incline button to return the backrest upright.
Controls and Massage Techniques
The remote control allows you to customize your massage experience.
Remote Control Layout:
The remote features:
- Power Indicator Lights: Show the master power switch status.
- Automatic Programs: Three programs (P1 - Sore Muscle Relief, P2 - Stress Therapy, P3 - Back Wellness) offer combinations of techniques for specific needs.
- Manual Massage Techniques: Four modes: Kneading, Percussion, Rolling, and Compression.
- Zone: Targets massage to a specific six-inch area using Position buttons.
- Foot and Calf Massage: Toggles between auto, high, and low speeds.
- Stop/Park: Stops massage and parks rollers at the top of the backrest.
- Range: Customizes vertical massage range.
- Power Recline: Reclines/inclines the backrest.
- Position: Sets massage roller position along the backrest.
- DEMO Button: (Implied by diagram).
Store the remote in the convenient pocket on the left side of the chair.
Massage Techniques Explained:
Massage Mode | What It Does | Benefits |
---|---|---|
Kneading | Kneads back in small, circular motions on both sides of the spine simultaneously. | Relieves tension and soreness by lifting and stretching muscles. Improves circulation and nutrient delivery to the spinal area. |
Percussion | Alternates rapid-tapping strokes along the spine, stimulating muscles and joints, similar to sports medicine techniques. | Flexes spinal joints, relieves spinal pressure, and invigorates the back. |
Rolling | Gently rolls up and down the back near the spine. | Warms and loosens muscles, preparing for deeper massage. Relieves muscle tension, improves circulation, and relaxes the back. |
Compression | Applies pressure to spinal muscles and joints with alternating strokes and a gentle rocking motion, mimicking sports medicine and chiropractic techniques. | Stretches and applies pressure to deep muscle tissue, forcing relaxation, while the rocking motion loosens spinal joints. Aids muscle/joint repair and can improve mobility and posture. |
Customize Massage Intensity
Massage-softening pads soften the intensity. Remove them for a stronger massage.
- Flip the head pillow to the back of the chair.
- Detach the top hook-and-loop fastener of the backrest pad from the chair.
- Open the horizontal zipper on the back of the backrest pad.
- Insert or remove the massage-softening pad as desired.
- Close the zipper.
- Attach the top of the backrest pad to the chair using hook-and-loop fasteners.
- Flip the head pillow back to the front of the chair.
Replacement pads are available from Human Touch for an additional charge.
Care and Maintenance
Follow these guidelines to keep your chair functioning well and looking its best.
Cleaning:
- Disconnect the power cord before cleaning.
- Do not use benzene, thinner, or other solvents.
- Vacuum dust from the backrest or armrests.
- Wipe soiled areas with a damp cloth, then a dry cloth.
- Use common upholstery cleaners for tough stains.
- Use a dry cloth only for the controller and power switch area.
Fabric Care:
Dust or vacuum frequently with a soft brush attachment. Faux suede can be brushed with a suede brush. Wipe with a slightly damp cloth. For tougher stains on non-leather products, use mild detergent and water. For leather products, use a leather furniture cleaning solution occasionally.
WARNING: Test cleaning solutions on an inconspicuous area first to ensure colorfastness.
Maintenance and Repair:
- The chair's mechanics are designed to be maintenance-free; no periodic lubrication or servicing is required.
- Service should only be performed by an authorized service center.
Storage:
- For long periods of non-use, cover the chair, coil the power cord, and store in a dust- and moisture-free environment.
- Do not store near heat or open flame. Avoid prolonged exposure to direct sunlight, which can cause fading or damage.
Miscellaneous:
- Do not insert foreign objects into massage nodes or the unit housing.
- Be careful not to overload the unit.
WARNING: The product has a thermal resetting protection device. If it stops suddenly, turn the main power switch OFF for at least 30 minutes before restarting.
Limited Warranty
Human Touch offers a limited warranty on its products, covering mechanical or structural defects in workmanship.
Coverage Guidelines:
Warranty begins on the original purchase date and includes:
- In-home (Labor): Technicians sent to repair the product at no charge.
- Parts Only (Parts): Covered parts provided at no charge.
- Structural (Metal Frame): Covered parts provided at no charge.
Human Touch Chairs | In-home Service | Parts | Structural |
---|---|---|---|
New Products | 1 year | 1 year | 5 years |
Refurbished Products | 1 year | 1 year | 5 years |
Floor Models (sold within 6 months of display) | 1 year | 1 year | 5 years |
For repairs, contact your retailer. USA customers can contact Human Touch Customer Service at (800) 355-2762 (6 AM-5 PM PST) or cs@humantouch.com. Fax: (800) 840-2940. All warranty service requires Human Touch approval.
General Limitations:
- Warranty valid in USA and Canada, provided the product is operated according to instructions and not misused.
- All service must be approved by Human Touch and performed by authorized technicians.
- Warranty covers only the massage chair; accessories are not covered.
- Exclusions apply to cosmetic items (fabrics, wood, foam, plastic covers, etc.).
- Human Touch is not responsible for losses or damages caused by equipment failure.
- Visit humantouch.com for full warranty details.
- Warranties do not apply to rental, business, commercial, or non-residential users.
- Proof of purchase (original receipt) is required for all warranty repairs.
Extended Warranties:
Extended warranty programs are available within 90 days of purchase. Visit humantouch.com for terms and pricing.
Specifications:
Specification | Details |
---|---|
Operating Voltage | AC 110-120V 60 Hz |
Power Consumption | 140 Watts |
Chair Size (reclined) | 68" L x 28" W x 20" H |
Product Weight | 140 Lbs. |
Required recline clearance | 14" |
Maximum load weight | 285 Lbs. |