VEVOR 512 Hz Pipe Locator User Manual

1. Specifications

Frequency: 512Hz
Modulation: None
Max Distance Capability: 6m/20ft
Battery: 6-pcs AA Alkaline batteries
Audio Output: 50 - 1000 Hz determined by signal strength
Weight: 1.8 lbs
Working Temperature: -4°F to 140° F (-20°C to 60°C)
Output: Loud-speaker, earphone and target alarming
Sensors: Digital sensor to derive peak and null signals
Mode: Far/Near Mode
Dimension: 548mm x 65mm x 50mm

2. Introduction to the digital display locator

The digital display locator consists of the following components:

3. General layout

  1. Signal strength indicator: The symbol 'S' indicates signal strength. The indicator moves to the right for a strong signal and to the left for a weak signal.
  2. Signal Sensitivity Value: The symbol 'D' represents the sensitivity. The 'Far' mode is recommended for initial setup, setting sensitivity to maximum ('9'). Use the '-' button to reduce the sensitivity value for more accurate readings.
  3. Far / Near Button: Controls overall sensitivity. The 'Far' position is recommended when initially locating the sonde. As you approach the transmitter, the signal strength indicator will show a peak value with 'D' at '4'. To pinpoint the precise location, switch to 'Near' mode if you cannot reduce the Signal Sensitivity Value further in 'Far' mode.

4. The Procedure to Use

  1. Step 1: Long press the 'POWER' button to turn on the device. Note any other transmissions to avoid misleading signals.
  2. Step 2: Turn on the sewer camera system with the camera probe on and transmitting at 512 Hz frequency.
  3. Step 3: Keep the locator parallel to the ground at hip waist height. Set 'D' to '9' and select 'Far' mode (Detect distance: 6m/20 feet).
  4. Step 4: Walk around and pay attention to the peak signal. When the signal column (symbol 'S') is less than 9, move or rotate the receiver in different directions. When the signal column reaches 9 (peak value), the direction shown by the antenna indicates the transmitter's orientation. The distance between the transmitter and receiver at this point is approximately 6m (20ft).
  5. Step 5: Walk around and adjust the '-' button to reduce 'D' to '8'. The signal ('S') in the 9th grade of the signal column will flash weakly. Move the receiver towards the transmitter until the signal reaches the full 9 grades. Then, decrease 'D' to positions '7, 6, 5, and 4' sequentially, continuously moving the receiver towards the direction indicated by the antenna.
  6. Step 6: When 'D' is '4' and the signal 'S' is at peak value, the receiver is approximately 2m away from the transmitter.
  7. Step 7: Change from 'Far' mode to 'Near' mode. Adjust the '+' button to increase 'D' to '9'. The signal ('S') should also be at full scale (peak value). Then, use the '-' button to reduce 'D' to '8, 7, 6, 5, 4, and 3' sequentially, moving the receiver towards the direction indicated by the antenna to find the peak signal value.
  8. Step 8: When 'D' is '3' and the signal 'S' is at peak value, congratulations! The distance between the receiver and transmitter is approximately 0.5m (1.65ft). The direction of the antenna at this point indicates the location of the transmitter.

5. Attention

6. The list of equipment in a whole set

  1. Aluminum box (with take-up spool cable and EVA cotton)
  2. Receiver
  3. Receiver antenna
  4. Earphone
Models: Sewer Camera with 512Hz Locator, Sewer, Camera with 512Hz Locator, 512Hz Locator, Locator

PDF preview unavailable. Download the PDF instead.

A1Gub1-jv-L WPS 文字

Related Documents

Preview VEVOR WP9604B Pipe Inspection System Instruction Manual
Comprehensive user manual for the VEVOR WP9604B Pipe Inspection System. Covers product features, specifications, operation, installation, charging, troubleshooting, and FCC information for effective plumbing and drain inspections.
Preview VEVOR Pipe Inspection System User Manual
User manual for the VEVOR Pipe Inspection System, covering product description, specifications, system installation, troubleshooting, and operating instructions for the HD DVR.
Preview VEVOR WP9600A Pipe Inspection System User Manual - Features, Specifications, and Operation
Comprehensive user manual for the VEVOR WP9600A Pipe Inspection System, covering features, specifications, installation, operation, and troubleshooting. Includes detailed instructions for use.
Preview VEVOR Pipe Inspection System User Manual WP9600A/9600A
This user manual provides detailed instructions for operating the VEVOR Pipe Inspection System, Model WP9600A/9600A. It covers product features, specifications, system installation, charging, troubleshooting, and DVR operation. Includes safety precautions and environmental compliance information.
Preview VEVOR WP9612FT Pipe Inspection System Instruction Manual
Comprehensive instruction manual for the VEVOR WP9612FT Pipe Inspection System, detailing features, specifications, installation, operation, and troubleshooting for effective drain and pipe inspection.
Preview VEVOR Mechanical Hand-Held Pipe Dredger RC-2005Q User Manual
User manual for the VEVOR Mechanical Hand-Held Pipe Dredger, model RC-2005Q. Includes operating instructions, parts list, applications, and technical data.
Preview VEVOR Sewer Camera System Dimensions and Specifications
Detailed dimensions and specifications for the VEVOR Sewer Camera System, model WPPEDOFTIR DC 12V and DDWKXSGDNK950S9AFV1. This pipeline inspection camera features a 512Hz locator, DVR function, IP68 rated camera, and adjustable LEDs.
Preview Pipe Inspection System Instruction Manual
Instruction manual for the Pipe Inspection System, detailing its features, specifications, and usage instructions for various camera types and monitor options. Includes charging and system installation guidance.