EMShape Neo Elite Body Sculpting Machine User Manual
Model: EMShape Neo Elite with Upgraded Higher Power
Manufacturer: M-SHAPE BEAUTY
User Notice
First of all, thank you for choosing the MSHAPE BEAUTY EMShape Neo® Elite with Upgraded Higher Power, which combines high-tech essence, fashionable style, and innovative functions. We hope to contribute beauty to you. Before using the instrument, please read this user manual carefully and keep it in a safe place for future use. This user guide is an operation guide, not a product guarantee.
MSHAPE BEAUTY reserves the right to interpret and modify the printing errors, software upgrades, and product improvements in this manual at any time. These changes will be directly incorporated into the new version of the user manual without notice. This user manual is compiled by MSHAPE BEAUTY, all rights reserved, privacy is subject to investigation.
Preface
Choose the relaxed & professional way to build muscle & burn fat, all in one go. Enjoy the immediate result of feeling healthier and stronger, and see visibly improved body shape in about 3 to 6 weeks' time.
This machine uses high-intensity magnetic waves plus RF to tone and sculpt the targeted body areas. Reduce fat & cellulite in your targeted body areas (stomach, thighs, arms, etc.) and Increase the amount of muscle fibers and cells.
The use of this machine is a safe, minimally invasive procedure, and easy to operate. There is no bleeding, no pain, and no side effects.
Thank you again, and please enjoy your MSHAPE BEAUTY EMShape Neo® Elite with Upgraded Higher Power.
This spa machine includes a personal training session with an expert instructor. We also offer complimentary certification (certificate that you can hang on the wall). Contact us after you receive your delivery to schedule your training session by Zoom or FaceTime.
I. Product Information & Specification
1.1 Product Information
A high-intensity magnetic pulsed energy penetrates several inches of subcutaneous muscle tissue safely and non-invasively. The energy acts on the muscle motor neural network in the brain to trigger continuous very strong muscle contractions.
The effect of this "super muscle exercise" is significant muscle building and fat apoptosis, which cannot be achieved by normal exercise alone.
1.2 Product Specification
Voltage: 100 V/ 110 V/ 220 V (Voltage selected according to your region)
Technologies: High-intensity EMS, RF, EMT
Modes: Stretching to warm up, deepen exercise, activate muscle, strengthen muscle, strong fat burning, relief
Pulse width: ~310us+/- 10%
Cooling system: air cooling
WARNING! RF energy on this machine is VERY STRONG and the temperature can become VERY HOT. To make the treatment comfortable and effective, please always start with a low level of RF.
Training is strongly recommended. MSHAPE BEAUTY is not responsible for any adverse effect that should occur due to misuse of the equipment by the operator.
1.3 List of Accessories
No. | Item | Quantity | Image Description |
---|---|---|---|
1 | Body | 1 Set | Main EMShape Neo Elite unit. |
2 | Handle | 4 | Applicator handles for treatment on Abdomen, Hips, Arms, and Legs. |
3 | Bandages | 5 | Straps for securing handles during treatment. |
4 | Power Cable | 1 | Cable to connect the device to a power source. |
II. Product Appearance
II.1 Front/Side View
The front/side view shows the main unit of the EMShape Neo Elite. It features a prominent touchscreen display showing treatment parameters, mode selection, and intensity levels. Below the screen are control buttons and indicator lights. Two handpieces are connected to the unit via cables.
II.2 Back View
The back view of the unit displays four connection ports for the handpieces, labeled sequentially as A-RF, B-RF, C-RF, and D-RF.
III. Warnings
III.1 Before Use
Use at least one hour after meals. DO NOT use when feeling full after eating.
Before starting the treatment, remove any metal jewelry you are wearing.
DO NOT operate on the head, neck/carotid artery, or near the thoracic gallery.
The area to be treated and the handles must be dry before starting the treatment.
During Treatment
DO NOT eat during treatment. Try to eat or drink at least 1 hour after the treatment.
DO NOT put/use any electronic products or metal objects on the machine during treatment.
DO NOT drink water during treatment.
DO NOT USE if with: heart disease, hypertension, thyroid, malignant tumor, renal failure, epilepsy and muscle strain.
Contraindications
DO NOT use if with metal or electronic implants (metal contraceptive ring, cardiac pacemaker, cardiac defibrillator, nerve stimulator, drug pump and stent).
DO NOT use if pregnant, menstruating, conceiving, or breastfeeding.
DO NOT use if had undergone major surgery, Diabetic and with cerebrovascular disease (stroke patients).
IV. Operating Position
The position of the handle must be the same as shown in the diagrams:
- Abdomen: Handles A and B are placed on the abdomen.
- Arm: Handle A is placed on the arm.
- Shoulder: Handles A and B are placed on the shoulder area.
- Leg: Handles A and B are placed on the leg.
- Hips: Handles A and B are placed on the hips.
The diagrams illustrate the correct placement of the applicator handles on different body parts for optimal treatment coverage.
V. Mode Selection & Operation
I. Function and Mode Selection
- After turning on the machine, the mode selection interface will appear.
- There are two modes: AUTO and MANUAL mode. Select which mode to use.
- After choosing the mode, select the appropriate settings according to gender, age range, and target treatment area.
- Click the start icon to begin working.
The interface allows selection of treatment parameters such as Gender (Female, Male), Age Group (<30, 30-39, 40-49, 50-59, 60+), and Area (Abdomen, Arm, Shoulder, Hips, Leg).
V.1 AUTO Mode
In AUTO mode, select the type of treatment from the options at the bottom of the interface:
- [HIIT]: Basic training for beginners
- [OBESITY]: Adaptation training
- [SLIGHTLY FAT]: Preliminary training
- [SHAPING]: Advanced training
- [LOSE WEIGHT]: Professional training
Note: Each mode automatically switches between 6 different frequencies. The first minute of each mode is a warm-up period.
The recommended intensity starts from 8% (weak) to 100% (strong). Intensity can be adjusted using the [-] and [+] buttons. It is recommended to set the intensity before the start of treatment and gradually increase it according to the patient's ability to withstand it.
The default working time for one treatment is 30 minutes, adjustable from 1 to 30 minutes.
Press the start button [▶] to begin. To pause, press the pause button [⏸]. To return to the previous interface, press the back button [◂].
Note: Use [-] and [+] buttons to adjust parameters when the device is in a paused state.
V.2 MANUAL Mode
In MANUAL mode, you can manually adjust the frequency on the interface:
- [F1]: Frequency 1, intensity range 3Hz (weak) to 150Hz (strong).
- [F2]: Frequency 2, intensity range 3Hz (weak) to 150Hz (strong).
- [F3]: Frequency 3, intensity range 3Hz (weak) to 150Hz (strong).
Note: Before treatment, set frequency parameters according to the required frequency. F1 works for 5 minutes, F2 for 1 minute, F3 for 5 minutes, and they cycle in sequence.
The recommended intensity is from 8% (weak) to 100% (strong). Intensity can be adjusted using the [-] and [+] buttons. Set the intensity before treatment and gradually increase it.
The working time can be adjusted from 1 minute to 30 minutes (default is 30 minutes).
Click the start button [▶]. If you need to pause, click the pause button [⏸]. Click the back button [◂] to return to the previous interface.
Note: Click [-] and [+] to adjust parameters when the device is in a paused state.
VI. Frequently Asked Questions
6.1 Who is suitable to use this machine?
The machine provides beneficial muscle tightening for most people, especially:
- Women who need to gain muscle and change their shape.
- Men who need to gain muscle and change their body.
- People who need to lose weight (suitable for both men and women, more suitable for busy office workers).
- Those who need to lose weight quickly (brides, models, actors, etc.).
- Postpartum mothers (experiencing separation of rectus abdominis) to improve abdominal muscles and achieve a flat abdomen.
6.2 Is there a difference in the effect of abdominal treatment when one or two treatment heads are used? How should we choose?
It is recommended that all patients use the two treatment heads simultaneously. Both treatment heads must be in full contact with the skin and not hover sideways or extend beyond the treatment area. This ensures all abdominal muscles are treated and activated. Both therapies are equally effective.
6.3 Will it melt fat while lifting the hips?
Many studies have confirmed that the metabolic activity of buttock fat is lower than that of abdominal fat. Therefore, it will not dissolve fat when treating buttocks.
6.4 Is this treatment safe? Will it affect the internal organs?
The only tissue that responds to energy is motor neurons, so it has no effect on other tissues, including organs.
6.5 Will it hurt during treatment?
The process is painless and non-invasive. No anesthesia is needed. The feeling during treatment is similar to your muscles during intense exercise.
6.6 How long will the treatment take? When will I see the effect?
A course of treatment typically takes 4-6 weeks, with 1-2 sessions per week. Significant reduction in fat and increase in muscle may be visible after 2-4 weeks of completing the recommended course. Usually, after 2-3 courses, muscle mass increases by approximately 14.5% and fat reduction by about 17.5%. This is an estimation and not based on clinical trials or guarantees.
6.7 How long will the effect last?
The effect can be maintained for one year after 6 courses. Some individuals may require additional treatments for optimal results. Consistent treatments every 2-3 months can help maintain the best condition.
6.8 How long does each treatment take?
A single treatment session is usually 30 minutes per area of the body.
6.9 Does the machine have radiation? Is it safe?
It emits less radiation than regular cellphones. Test reports confirm that the radiation range of this machine is within the national safety standards for electrical appliances.
6.10 How thick of fat can the machine penetrate?
This machine can penetrate several inches into the muscle layer. However, if the customer's fat layer is very thick, the energy may not penetrate the muscle tissue thoroughly, making it difficult to achieve effective muscle contraction and therapeutic results.
6.11 Can it be combined with other body care treatments?
Yes, it can be combined with non-traumatic fat-removing treatments (e.g., other fat-reducing equipment) to enhance fat elimination. It can also be combined with postpartum repair care to improve the health and physical well-being of postpartum women.
VII. Maintenance
- Ensure the power supply is stable. If the local power supply voltage is unstable, it is recommended to use a regulated power supply with matching power.
- The power cord of the socket should be rated for more than 1.5 square meters.
- When using this device, keep it away from walls and maintain a space of 30cm around the device for heat dissipation.
- After each treatment, clean the unit with a mild disinfectant.
- Please do not use alcohol or corrosive solvents to clean the host and handle to avoid damage.
- During treatment, avoid damaging the handle line by pressing or bending it.
- DO NOT place the instrument in environments with high temperature, humidity, dust, or direct sunlight. The instrument should be kept in a dry, cool, and ventilated room with a temperature between 5 to 40°C and humidity no more than 80%.