Welcome to your EMShape Neo Plus Body Sculpt Machine 8500W.
User Notice
Thank you for choosing the MSHAPE BEAUTY EMShape Neo® Plus Body Sculpt Machine 5 in 1, which combines high-tech essence, fashionable style, and innovative functions. We hope to contribute beauty to you. Before using the instrument, please read this user manual carefully and keep it in a safe place for future use. This user guide is an operation guide, not a product guarantee.
MSHAPE BEAUTY reserves the right to interpret and modify the printing errors, software upgrades, and product improvements in this manual at any time. These changes will be directly incorporated into the new version of the user manual without notice. This user manual is compiled by MSHAPE BEAUTY, all rights reserved, privacy is subject to investigation.
Preface
Thank you for choosing MSHAPE Beauty EMShape Neo Plus Body Sculpt Machine 8500W.
EMShape Neo Plus is engineered to perform body sculpting more effectively than any alternative equipment available in the global beauty marketplace. The machine's sleek design and high-end specifications guarantee maximum efficiency and fast, impressive benefits. Let your spa's clientele indulge in a spa treatment that offers premium results.
Harness the power of the latest HIEMT technology and synchronized RF to deliver efficient and effective muscle building and fat reduction results. Procedure is 100% non-invasive, safe and painless, with no downtime.
Please read this User Manual carefully in order to use the machine properly and to protect the machine from unnecessary damages.
Thank you again, and please enjoy your MSHAPE Beauty body sculpting equipment!
Product Information & Specification
1.1 Product Information
This machine uses the latest HIEMT technology + synchronized RF to deliver efficient & effective muscle building + fat reduction. This process triggers the production of new collagen chains, thereby increasing muscle support and volume.
HIEMT (high-intensity electromagnetic technology) uses strong focused electromagnetic waves to stimulate and train the targeted muscle tissue. During a 30-minute treatment session, focused magnetic waves penetrate up to 8cm of muscle tissue, forcing the muscles to contract involuntarily many thousands of times. Such supra-maximal contractions are not achievable by normal exercise. The body naturally responds to this supra-maximal exercise by rebuilding muscle tissue, making the body more toned and stronger. As with normal exercise, there is a large amount of natural fat decomposition, resulting in body slimming.
1.2 Product Specification
- Voltage: 100 V/ 110 V/ 220 V (Voltage selected according to your region)
- Technologies: High-intensity EMS, RF, EMT
- Modes: Stretching to warm up, deepen exercise, activate muscle, strengthen muscle, strong fat burning, relief
- Pulse width: ~310us+/- 10%
- Cooling system: air cooling
WARNING! RF energy on this machine is VERY STRONG and temperature can become VERY HOT. To make the treatment comfortable and effective, please always start with low level of RF.
Training is strongly recommended. MSHAPE BEAUTY is not responsible for any adverse effect that should occur due to misuse of the equipment by the operator.
1.3 List of Accessories
Accessory | Quantity |
---|---|
Main Unit | 1 |
Flat Handle | 2 |
Curved Handle | 2 |
Pelvic Floor Training Cushion | 1 |
Belt Straps | 4 |
Power Cord | 1 |
Product Appearance
Front View
The front view shows the main unit with an LCD screen. Two handles are visible: a Flat Handle and a Curved Handle.
Back View
The back view displays the handle sockets labeled A, B, C, and D, along with the Power Switch and Power Cord Socket.
Side View
The side view shows the overall profile of the machine, highlighting the connections for the handles and the energy output ports.
Accessories Application
The accessories are designed for different treatment areas:
- Handles can be applied to the abdomen and buttocks.
- Handles can also be applied to the legs and arms.
Warnings
?Use at least one hour after meals. DO NOT use when feeling full after eating.
??Before using the instrument, remove any metal jewelry you are wearing. DO NOT touch metal objects during the treatment.
[hand touching skin icon]Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
▶️⬇️Start with the lowest level, and then increase the intensity sequentially according to the user's skin tolerance.
??️DO NOT eat during machine operation. Try to eat some protein after one hour of session.
?DO NOT use if there are open wounds or any skin infections such as eczema or dermatology issues.
❤️?DO NOT use if there are heart conditions (such as with arrhythmias) especially those with pacemakers.
?DO NOT use if diagnosed with cancer.
?DO NOT use if diagnosed with infectious disease.
?DO NOT use if pregnant, menstruating, conceiving, or breastfeeding.
⚕️DO NOT use if you have undergone major surgery, Diabetic and with cerebrovascular disease (stroke patients) must avoid.
?DO NOT use if have metal on any part of the body.
Treatment Position
The position of the handles during treatment must be as shown in the images for every area of the body:
- Abdomen: Handles placed on the abdomen.
- Hips: Handles placed on the hips.
- Shoulder: Handles placed on the shoulder area.
- Leg: Handles placed on the thighs.
- Arm: Handles placed on the arm.
Notes:
- Be careful to avoid positions of ribs and bones.
- When operating the abdomen, select one or two handles according to the size of the customer's abdomen.
- It is recommended to treat one part for 30 minutes.
- Before operation, remove metal objects worn on the body and avoid metal objects on clothes.
- Before operation, fasten the bandage, insert the handle into the bandage and fix it, paying attention to the close position of the working head.
- Adjust the energy intensity before starting the operation. The treatment starts from low intensity and gradually improves according to the comfort of customers.
- If the customer doesn't feel anything during the operation, the energy intensity can be appropriately strengthened, and the degree of strengthening should be confirmed with the customer.
Mode Selection & Operation
a. Mode Selection
1. Function and Mode Selection: On the interface, select the type of treatment on the function selection interface.
2. General Mode Categories: There are two General Mode Categories: AUTO and MANUAL mode. Select which one to use.
3. Setting Information: On the information interface, select the appropriate settings according to gender, age range, and fat thickness.
Figure 1: Shows the selection between AUTO and MANUAL modes with icons for "Build muscle & Burn fat".
Figure 2: Shows the input interface for setting parameters like Sex (Female/Male), Age Group (<30, 30-39, 40-49, 50-59, 60+), and Area (Abdomen, Arm, Shoulder, Hips, Leg).
Click the icons shown above to start working.
b. AUTO Mode
Figure 3: Displays the AUTO mode interface. Key elements include: AB Handle Intensity, RF intensity of AB handle, Treatment Level Selection, Treatment Time, and CD Handle Intensity, RF intensity of CD handle.
II. AUTO MODE
- When using AUTO mode, there is a choice of TREATMENT LEVELS. Select a TREATMENT LEVEL according to the patient's condition. When in doubt, start with HIIT to be conservative.
- The handle strengths A and B can be adjusted ranging from 8% (weak) to 100% (strong). Set the handle strength before the start of treatment. The treatment starts from low intensity and should be gradually increased according to the patient's tolerance.
- AB: Handle intensity of A and B, click [-] and [+] to adjust intensity.
- CD: Handle intensity of C and D, click [-] and [+] to adjust intensity.
- AB-RF: RF intensity of AB handle, click [-] and [+] to adjust intensity.
- CD-RF: RF intensity of CD handle, click [-] and [+] to adjust intensity.
- Set the working time. The default working time of one treatment is 30 minutes. This can be adjusted from 5 minutes to 60 minutes.
- Click the Start button to start the treatment. Click the Pause button if you need to pause the treatment.
NOTE: Adjust the settings when the device is in Pause mode.
c. Manual Mode
Figure 4: Shows the selection screen for Manual mode, similar to Figure 1.
Figure 5: Displays the MANUAL mode interface with parameters for AB and CD handles, including intensity, RF intensity, and frequency settings (F1, F2, F3).
III. MANUAL MODE
- On the interface, select Manual mode.
- On the information interface (Figure 2), select the appropriate settings according to gender, age range, and fat thickness.
- Adjust the frequency. Please see the next page for frequency setting.
- Set the frequency. Adjustment settings are below:
- F1: Frequency 1, the intensity range is 3HZ (weak) to 200Hz (strong)
- F2: Frequency 2, the intensity range is 3HZ (weak) to 200Hz (strong)
- F3: Frequency 3, the intensity range is 3HZ (weak) to 200Hz (strong)
- Before the start of treatment, set the frequency parameters according to the required frequency.
- F1 frequency works for 5 minutes,
- F2 frequency works for 1 minute,
- F3 frequency works for 5 minutes, and
- F1, F2, and F3 frequencies are cycled in sequence.
- The handle strengths A and B can be adjusted ranging from 8% (weak) to 100% (strong). Set the handle strength before the start of treatment. The treatment starts from low intensity and should be gradually increased according to the patient's tolerance.
- AB: Handle intensity of A and B, click [-] and [+] to adjust intensity.
- CD: Handle intensity of C and D, click [-] and [+] to adjust intensity.
- AB-RF: RF intensity of AB handle, click [-] and [+] to adjust intensity.
- CD-RF: RF intensity of CD handle, click [-] and [+] to adjust intensity.
- Set the working time. The default working time of one treatment is 30 minutes. This can be adjusted from 5 minutes to 60 minutes.
- Click the Start button to start the treatment. Click the Pause button if you need to pause the treatment.
NOTE: Adjust the settings when the device is in Pause mode.
d. Pelvic Floor Cushion
1. Setup: Align the handle with the socket on the back of the instrument and insert it. Insert the power cord into the rear socket of the device, turn ON the power switch, and the device will start immediately.
2. Usage: Place a cushion on the chair, sit on the center, and relax.
Diagram: Shows an ergonomic pelvic floor cushion designed according to the human body curve for comfortable support, indicating areas for hip protector and thigh support on both left and right sides.
NOTE: Use MANUAL mode when using the Pelvic Floor Cushion. The recommended setting for F1: 110 Hz, F2: 5 Hz, and F3: 140 Hz.
Treatment Levels in Auto Mode
The following table details treatment levels for different modes:
MODE | STAGE 1 | STAGE 2 | STAGE 3 | STAGE 4 | STAGE 5 | STAGE 6 |
---|---|---|---|---|---|---|
HIIT | 3 Hz/1 minute | 140 Hz/ 5 minutes | 4 Hz/1 minute | 200 Hz/ 5 minutes | 4 Hz/1 minute | 160 Hz/ 5 minutes |
Obesity | 5 Hz/1 minute | 200 Hz/ 5 minutes | 5 Hz/1 minute | 80 Hz/ 5 minutes | 5 Hz/1 minute | 140 Hz/ 5 minutes |
Slightly Fat | 5 Hz/1 minute | 200 Hz/ 5 minutes | 5 Hz/1 minute | 160 Hz/ 5 minutes | 5 Hz/1 minute | 140 Hz/ 5 minutes |
Shaping | 4 Hz/1 minute | 160 Hz/ 5 minutes | 4 Hz/1 minute | 200 Hz/ 5 minutes | 4 Hz/1 minute | 160 Hz/ 5 minutes |
Lose Weight | 5 Hz/1 minute | 200 Hz/ 5 minutes | 5 Hz/1 minute | 160 Hz/ 5 minutes | 5 Hz/1 minute | 200 Hz/ 5 minutes |
Mode Descriptions:
- HIIT: Basic training for beginners (suitable for people who hardly exercise, effective basic training for weak muscle groups).
- Obesity: Adaptation training (suitable for primary exercisers who have not exercised for a long time, and also suitable for obese people with less muscles).
- Slightly Fat: Preliminary training (suitable for primary exercisers with insufficient muscle or slightly higher body fat, also suitable for slightly obese people).
- Shaping: Advanced training (suitable for intensive endurance training, suitable for all fitness groups and regular exercisers, and also suitable for obese people. As the training frequency further increased, the load is gradually increased to increase the strength and dimensionality of muscle contraction. For shaping.).
- Lose Weight: Professional training (suitable for intensive training, suitable for regular exercisers and athlete groups, and also suitable for obese people. Due to increase in training frequency and high intensity of action, the fat burning ability of muscles is improved, and fat is consumed at high frequency.).
Troubleshooting Solutions
Machine Error | Cause | Troubleshoot |
---|---|---|
Machine not working | 1. Power plug not inserted 2. Switch not ON 3. Power fuse failure |
1. Check the power 2. Check the switch 3. Replace the fuse |
Handle not working | Check if the connection is loose | Disconnect and reconnect the handle |
Maintenance
VII.1 Regular Use
- To make sure that the machine will last longer, after each 30 minutes of using the machine, allow the machine to rest/cool down for 5 minutes before starting the treatment again.
- Check the power socket, confirm that there is a reliable connection to the ground.
- Check if the power cord is damaged before use; do not use if damaged.
VII.2 Cleaning
- Perform regular cleaning to ensure sanitation and proper function.
- The outside body of the machine can be cleaned using a damp cloth or alcohol wipes.
- Clean only when the machine is unplugged and disconnected from the power source.