SECOP FRK11G Compressor Technical Data
Model: FRK11G
Compressor Design
Attribute | Value |
---|---|
Oil type | Polyolester |
Oil viscosity | 19,2 cSt |
Oil quantity | 240 cm³ / 8,1 fl.oz |
Refrigerant charge - tech. limit | 700g / 24,7oz |
Free gas volume comp. | 1495 cm³ / 50,6 fl.oz |
Weight | 9,7kg / 21,4lbs |
Motor protection | external |
Winding resistance main | 8,40 Ω (at 25°C) |
Winding resistance aux | 11,90 Ω (at 25°C) |
Max. winding temp. | 125°C / 257°F |
Max. discharge temp. | 130°C / 266°F |
Additional note | Very good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake. Special design for high refrigerant charge. |
General Configurations with FRK11G
Configuration | Conf. 1 | Conf. 2 |
---|---|---|
Motor configuration | CSIR | CSIR |
Power supply (nominal) | 220-240V/50Hz | 208-230V/60Hz |
Number of phases | 1 | 1 |
Voltage range | 187-254V | 198-253V |
Approvals | VDE, CB, UL in progress | VDE, CB, UL in progress |
Starting torque | HST | HST |
Note | Electrical equipment is included and pre-assembled to compressor. |
Applications with FRK11G
Attribute | Conf. 1 | Conf. 2 |
---|---|---|
Refrigerant | R134a | R134a |
Application | LBP+MBP+HBP | LBP+MBP |
System cooling | fan 3m/s | fan 3m/s |
Hot gas defrost | OK | OK |
Long interval pull down | OK | OK |
Electrical Data - Configurations with FRK11G
Attribute | Conf. 1 | Conf. 2 |
---|---|---|
Starting device type | relay | relay |
Run capacitor | -/- | -/- |
Start capacitor | 80μF | 80μF |
LRA (locked rotor amps / 4s/ U(N)) | 13,5A | 13,5A |
RLA (rated load amps / 1s/ U(N)) | 2,1A | 2,1A |
Cut in current (U(N)) | 12,3A | 12,3A |
Compressor Dimensions
Dimension | Value (mm / in) | Diagram Reference |
---|---|---|
A Height | 182mm / 7,17in | A |
B Height | 175mm / 6,89in | B |
C Length shell | 198mm / 7,8in | C |
D Length w. cover | 238mm / 9,37in | D |
E Width | 160mm / 6,3in | E |
Connectors:
Type | Diameter (mm / in) | Material | Horizontal angle | Vertical angle | Position I/h/w (mm / in) | Straight tube I. (in) |
---|---|---|---|---|---|---|
Suction (X) | øi 8,11-8,29 / øi 0,32-0,33 | copper | +2° | +2° | 119/73/59 / 4,7/2,9/2,3 | 14 / 0,5 |
Discharge (Y) | øi 6,11-6,29 / øi 0,24-0,25 | copper | 35° | 30° | 117/107/66 / 4,6/4,2/2,6 | 14 / 0,5 |
Process (Z) | øi 6,11-6,29 / øi 0,24-0,25 | copper | 13° | 40° | -88/101/71 / -3,5/4/2,8 | 14 / 0,5 |
Compressor Fixation
Baseplate Dimensions:
Type | Dimension (mm / inch) |
---|---|
Baseplate | 204 / 8.03 |
Bw | 132 / 5.2 |
ØL | 101.6 / Ø 4 |
ØS | 19 / Ø 0.75 |
ØE | 16 / Ø 0.63 |
Large holes | 165 / 6.5 |
Small holes | 4 / - |
Mounting Accessories:
Accessory | One Comp. | Multi Pack |
---|---|---|
Bolt joint | M6 | Ø16mm | 118-1917 | 118-1918 |
Bolt joint | Ø1/4" | Ø16mm | 118-1946 | - |
Bolt joint | Ø1/4" | Ø19mm | 118-1949 | - |
Snap-on | ø7,3 | ø16mm | 118-1947 | 118-1919 |
Application notes: Provision for PE Grounding is located at the PE Stamp on the compressor. Suctiongas connector and Process connector can be switched (minor loss of cooling capacity).
Operation Pressure Range
Condensing pressure (saturation temperature) vs. Evaporation pressure (saturation temperature)
A graph shows the relationship between condensing pressure and evaporation pressure for continuous and transitory operation. The X-axis represents evaporation pressure in [bar] and [°C/°F], while the Y-axis represents condensing pressure in [bar] and [°C/°F].
Performance Tables
Tables detail performance data including cooling capacity, COP, EER, power consumption (P1), current consumption (A), and ref. mass flow (m) under various conditions for R134a refrigerant at 220V/50Hz and 230V/60Hz.
Configuration 1: R134a, 220V/50Hz, CSIR, fan 3m/s, VDE, CB, UL in progress
Conditions | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | Current [A] | Ref. mass flow [kg/h] | |
---|---|---|---|---|---|---|---|---|---|---|
Evaporating temp. (°C/°F) | ||||||||||
-35/-31 | 117,5 | 401 | 101,1 | 0,87 | 2,97 | 0,75 | 135,3 | 1,26 | 2,54 | |
-25/-13 | 207,3 | 708 | 178,4 | 1,21 | 4,14 | 1,04 | 171,2 | 1,36 | 4,49 | |
-15/5 | 352,0 | 1202 | 303,0 | 1,62 | 5,55 | 1,40 | 216,8 | 1,52 | 7,67 | |
-10/14 | 447,0 | 1527 | 384,7 | 1,85 | 6,32 | 1,59 | 241,4 | 1,62 | 9,78 | |
0/32 | 686,7 | 2345 | 591,0 | 2,37 | 8,08 | 2,04 | 290,3 | 1,82 | 15,19 | |
5/41 | 833,0 | 2845 | 716,9 | 2,66 | 9,09 | 2,29 | 313,1 | 1,92 | 18,54 | |
10/50 | 998,1 | 3409 | 858,9 | 2,99 | 10,21 | 2,57 | 333,8 | 2,01 | 22,40 | |
Condensing temp. (°C/°F) | ||||||||||
pc= 45/113 | -35/-31 | 95,3 | 326 | 82,0 | 0,73 | 2,51 | 0,63 | 129,8 | 1,25 | 2,27 |
pc= 55/131 | -25/-13 | 176,0 | 601 | 151,4 | 1,02 | 3,48 | 0,88 | 172,8 | 1,37 | 4,21 |
Return gas temp. RGT=32/90 | -15/5 | 302,4 | 1033 | 260,2 | 1,33 | 4,54 | 1,14 | 227,3 | 1,56 | 7,28 |
-10/14 | 459,1 | 1568 | 395,1 | 1,50 | 5,10 | 1,29 | 257,0 | 1,68 | 9,31 | |
Liquid temp. Tliq= 45/113 | 0/32 | 592,6 | 2024 | 510,0 | 1,87 | 6,38 | 1,61 | 317,4 | 1,94 | 14,49 |
5/41 | 719,5 | 2457 | 619,2 | 2,08 | 7,09 | 1,79 | 346,6 | 2,07 | 17,73 | |
10/50 | 863,0 | 2947 | 742,7 | 2,31 | 7,88 | 1,99 | 374,1 | 2,19 | 21,45 |
Configuration 2: R134a, 230V/60Hz, CSIR, fan 3m/s, VDE, CB, UL in progress
Conditions | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | Current [A] | Ref. mass flow [kg/h] | |
---|---|---|---|---|---|---|---|---|---|---|
Evaporating temp. (°C/°F) | ||||||||||
-35/-31 | 141,0 | 482 | 121,3 | 1,05 | 3,58 | 0,90 | 134,6 | 1,16 | 3,04 | |
-25/-13 | 248,1 | 847 | 213,5 | 1,27 | 4,33 | 1,09 | 195,7 | 1,33 | 5,37 | |
-15/5 | 420,2 | 1435 | 361,7 | 1,65 | 5,62 | 1,42 | 255,2 | 1,52 | 9,16 | |
-10/14 | 533,3 | 1821 | 459,0 | 1,87 | 6,40 | 1,61 | 284,7 | 1,62 | 11,67 | |
0/32 | 665,8 | 2274 | 573,0 | 2,12 | 7,23 | 1,82 | 314,4 | 1,73 | 14,64 | |
5/41 | 818,7 | 2796 | 704,6 | 2,38 | 8,12 | 2,05 | 344,4 | 1,85 | 18,11 | |
7,2/45 | 1077,0 | 3678 | 926,9 | 2,77 | 9,47 | 2,39 | 388,5 | 2,03 | 24,06 | |
Condensing temp. (°C/°F) | ||||||||||
pc= 45/113 | -35/-31 | 112,6 | 385 | 96,9 | 0,83 | 2,82 | 0,71 | 136,2 | 1,16 | 2,68 |
pc= 55/131 | -25/-13 | 210,0 | 717 | 180,7 | 1,04 | 3,55 | 0,90 | 201,9 | 1,35 | 5,02 |
Return gas temp. RGT=32/90 | -15/5 | 360,9 | 1233 | 310,6 | 1,33 | 4,55 | 1,15 | 271,1 | 1,58 | 8,69 |
-10/14 | 459,1 | 1568 | 395,1 | 1,49 | 5,10 | 1,29 | 307,4 | 1,71 | 11,10 | |
Liquid temp. Tliq= 45/113 | 0/32 | 573,7 | 1959 | 493,8 | 1,66 | 5,68 | 1,43 | 345,1 | 1,85 | 13,95 |
7,2/45 | 706,0 | 2411 | 607,6 | 1,84 | 6,27 | 1,58 | 384,4 | 2,01 | 17,27 | |
7,2/45 | 929,4 | 3174 | 799,9 | 2,09 | 7,15 | 1,80 | 444,2 | 2,26 | 22,99 |
Electrical Accessories / Wiring Diagram
Diagrams illustrating electrical accessories and wiring for the compressor configurations are provided.
Components (incl. and pre. assembl.):
- a5 current relay (T0377/L6-S1): 117U7071
- start capacitor (80µF, 6.3mm): 117U5001
- b, d cover + clamp + screws (5VA-compl.): 103N0600
Alternative components:
- b, d 100x cover + clamp + screws (5VA): 103N2060
- b, d cover + clamp + screws (5VA) in bag: 103N1060
Ambient/Machine Room Temperatures
- Ambient temperature range: 10 - 43°C / 50 - 110°F
- Machine room temperature range: 10 - 48°C / 50 - 119°F
- Compressor cooling: fan 3m/s