SECOP Compressor Technical Data

Model: KLE4.8GFTX

Sales Code: 106G5507

General Compressor Specifications

Compressor Design Details
DesignationKLE4.8GFTX
Voltage/Frequency220-240V/50Hz 1~ & 208-230V/60Hz 1~
Oil TypePolyolester
Oil Viscosity19,2 cSt
Oil Quantity240cm³ / 8,1 fl.oz
Refrigerant Charge (Tech. Limit)250g / 8,8oz
Free Gas Volume (Comp.)1545cm³ / 52,2 fl.oz
Weight9,3kg / 20,5lbs
Motor ProtectionExternal
Winding Resistance (Main)13,1 Ω (at 25°C)
Winding Resistance (Aux)25,3 Ω (at 25°C)
Max. Winding Temp.125°C / 257°F
Max. Discharge Temp.130°C / 266°F
Additional NoteGood robustness against liquid intake. Ice-cube maker optimization - indirect suction intake.
Refrigerant and Displacement
Refrigerant(s)R134a, R513A
Displacement4,8cm³ / 0,29 cu.in
Compressors on Pallet100

Visual Description: The compressor is a hermetic unit with a distinctive SECOP KL-Series branding. It features electrical connections and mounting points typical for refrigeration compressors.

Configuration Details

Configuration 1 (220-240V/50Hz)

General Configuration 1
Motor ConfigurationCSIR
Power Supply (Nominal)220-240V/50Hz
Number of Phases1
Voltage Range187-254V
ApprovalsVDE, CB, CCC, UL
Starting TorqueHST
NoteHousing with dip-tray fixture (omega bracket).
Applications (Conf. 1)
RefrigerantR134a
ApplicationLBP+MBP+HBP
System CoolingFan 3m/s
Hot Gas DefrostOK
Long Interval Pull DownOK
Electrical Data (Conf. 1)
Starting Device TypeRelay
Run Capacitor- / -
Start Capacitor80µF
LRA (Locked Rotor Amps)10,5A
RLA (Rated Load Amps)1A
Cut-in Current10,2A

Configuration 2 (208-230V/60Hz)

General Configuration 2
Motor ConfigurationCSIR
Power Supply (Nominal)208-230V/60Hz
Number of Phases1
Voltage Range198-253V
ApprovalsVDE, CB, CCC, UL
Starting TorqueHST
NoteHousing with dip-tray fixture (omega bracket).
Applications (Conf. 2)
RefrigerantR134a
ApplicationLBP+MBP
System CoolingFan 3m/s
Hot Gas DefrostOK
Long Interval Pull DownOK
Electrical Data (Conf. 2)
Starting Device TypeRelay
Run Capacitor- / -
Start Capacitor80µF
LRA (Locked Rotor Amps)10,5A
RLA (Rated Load Amps)1A
Cut-in Current10,2A

Compressor Dimensions and Fixation

Housing Dimensions
Dimension[mm][in]
A Height1827,17
B Height1756,89
C Length Shell1987,8
D Length w. Cover2389,37
E Width1606,3
Connectors (Suction X, Discharge Y, Process Z)
ParameterSuction (X)Discharge (Y)Process (Z)
Diameter [mm]øi 8,11-8,29øi 6,11-6,29øi 6,11-6,29
Diameter [in]øi 0,32-0,33øi 0,24-0,25øi 0,24-0,25
MaterialCopperCopperCopper
Horizontal Angle+2° (35°)13°
Vertical Angle+2° (30°)40°145°
Position [mm] (l/h/w)119/73/59117/107/66-88/101/71
Position [in] (l/h/w)4,7/2,9/2,34,6/4,2/2,6-3,5/4/2,8
Straight Tube Length [mm]141414
Straight Tube Length [in]0,50,50,5

Diagram Description: The compressor dimensions diagram illustrates the physical layout with labels A through E for height and width, and X, Y, Z for suction, discharge, and process connectors respectively. It also shows horizontal and vertical angles for the connectors and their positions.

Compressor Fixation
Fixation TypeDetails
BaseplateDimensions: 204mm (8.03in) L x 132mm (5.2in) W. Features large holes (Ø19mm/0.75in) and small holes (Ø16mm/0.63in).
Bolt JointsM6 (Ø16mm), 1/4" (Ø16mm), 1/4" (Ø19mm).
Snap-onØ7,3mm (Ø16mm).

Diagram Description: The compressor fixation diagram shows the baseplate with mounting hole patterns (large and small). It details bolt joints and snap-on fixation methods, including dimensions and associated hardware like washers, nuts, sleeves, and rubber grommets.

Mounting Accessories:

Application Notes: Provision for PE Grounding is located at the PE Stamp on the compressor. Suction gas connector and Process connector can be switched (minor loss of cooling capacity).

Operating Conditions and Performance

Ambient and Machine Room Temperatures:

Diagram Description: The "Operation Pressure Range" graphs illustrate the relationship between condensing pressure and evaporation pressure. Two sets of curves are shown for continuous and transitory operation, typically plotted in bars and °C/°F.

Diagram Description: The "Electrical accessories / wiring diagram" shows the compressor's electrical components, including a current relay (a5), a start capacitor (c), and a cover/clamp/screws assembly (b, d). It depicts how these components connect to the compressor's terminals.

Optimization + Standard Conditions (Conf. 1: 220-240V/50Hz)
ConditionsCooling CapacityCOPEERP1 [W]I [A]Ref. Mass Flow [kg/h]
[°C][°F][W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W/W][Btu/Wh][kcal/Wh]
pe -23°C / -10°F
pc 54°C / 130°F
RGT 32°C / 90°F
Tliq 32°C / 90°F
-23-10129,7443111,61,264,311,09102,81,182,52ASHRAE LBP
pe -7°C / 20°F
pc 54°C / 130°F
RGT 35°C / 95°F
Tliq 46°C / 115°F
-720279,9956240,91,886,421,62148,91,296,11ASHRAE MBP
pe 7,2°C / 45°F
pc 54°C / 130°F
RGT 35°C / 95°F
Tliq 46°C / 115°F
7,245502,31715432,32,719,262,33185,21,4111,14ASHRAE HBP
pe -35°C / -31°F
pc 40°C / 104°F
RGT 20°C / 68°F
Tliq 40°C / 104°F
-35-3164,422055,40,883,010,7673,01,121,41EN12900 LBP
pe -10°C / 14°F
pc 45°C / 113°F
RGT 20°C / 68°F
Tliq 45°C / 113°F
-1014241,7825208,01,876,381,61129,31,245,66EN12900 MBP
pe 5°C / 41°F
pc 50°C / 122°F
RGT 20°C / 68°F
Tliq 50°C / 122°F
541428,21462368,52,498,512,15171,81,3610,79EN12900 HBP
Performance Tables (Conf. 1: 220-240V/50Hz)
ConditionsCooling CapacityCOPEERP1 [W]I [A]Ref. Mass Flow [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W/W][Btu/Wh][kcal/Wh]
Cond. Pressure [°C/°F]
pc= 45/113
-35/-3160,420652,00,832,850,7272,41,121,30
-25/-13111,838296,21,174,001,0195,51,172,42
-15/5195,3667168,11,655,651,42118,11,224,26
Return Gas Temp.
RGT= 32/90
-10/14250,7856215,81,946,621,67129,31,245,49
0/32392,41340337,72,598,832,23151,71,308,68
Liquid Temp
Tliq= 45/113
5/41479,91639413,02,9510,062,53163,01,3310,69
15/59691,72362595,33,7212,723,20185,81,4115,67
Cond. Pressure [°C/°F]
pc= 55/131
-35/-3148,816742,00,722,460,6267,81,111,16
-25/-1394,732481,50,973,300,8397,91,172,27
Return Gas Temp
RGT= 32/90
-15/5167,6572144,31,324,521,14126,61,244,04
-10/14215,8737185,71,545,251,32140,41,275,22
0/32339,11158291,82,036,921,74167,31,358,29
Liquid Temp
Tliq= 55/131
5/41415,51419357,62,307,871,98180,41,3910,24
15/59601,12053517,32,929,962,51206,11,4115,10
Optimization + Standard Conditions (Conf. 2: 208-230V/60Hz)
ConditionsCooling CapacityCOPEERP1 [W]I [A]Ref. Mass Flow [kg/h]
[°C][°F][W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W/W][Btu/Wh][kcal/Wh]
pe -23°C / -10°F
pc 54°C / 130°F
RGT 32°C / 90°F
Tliq 32°C / 90°F
-23-10154,4527132,91,304,441,12118,61,133,00ASHRAE LBP
pe -7°C / 20°F
pc 54°C / 130°F
RGT 35°C / 95°F
Tliq 46°C / 115°F
-720330,51129284,41,926,551,65172,21,267,21ASHRAE MBP
pe 7,2°C / 45°F
pc 54°C / 130°F
RGT 35°C / 95°F
Tliq 46°C / 115°F
7,245587,32006505,42,719,252,33216,91,3913,03ASHRAE HBP
pe -35°C / -31°F
pc 40°C / 104°F
RGT 20°C / 68°F
Tliq 40°C / 104°F
-35-3181,627970,20,943,220,8186,71,081,79EN12900 LBP
pe -10°C / 14°F
pc 45°C / 113°F
RGT 20°C / 68°F
Tliq 45°C / 113°F
-1014281,8963242,61,876,391,61150,61,206,60EN12900 MBP
pe 5°C / 41°F
pc 50°C / 122°F
RGT 20°C / 68°F
Tliq 50°C / 122°F
541500,81710431,02,458,372,11204,31,3512,62EN12900 HBP
Performance Tables (Conf. 2: 208-230V/60Hz)
ConditionsCooling CapacityCOPEERP1 [W]I [A]Ref. Mass Flow [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W/W][Btu/Wh][kcal/Wh]
Cond. Pressure [°C/°F]
pc= 45/113
-35/-3176,126065,50,893,050,7785,31,071,64
-25/-13131,2448112,91,214,131,04108,41,112,84
-15/5227,5777195,81,685,721,44135,81,174,96
Return Gas Temp.
RGT= 32/90
-10/14292,4999251,61,946,631,67150,61,206,40
0/32458,11565394,32,538,642,18181,01,2810,13
Liquid Temp
Tliq= 45/113
5/41560,01912481,92,859,752,46196,21,3312,47
15/59804,32747692,23,5712,203,07225,21,4218,22
Cond. Pressure [°C/°F]
pc= 55/131
-35/-3161,020852,50,712,430,6185,91,081,45
-25/-13113,138697,40,993,390,85114,11,122,71
Return Gas Temp
RGT= 32/90
-15/5198,8679171,11,374,661,18145,51,194,78
-10/14255,4872219,81,585,391,36161,91,236,18
0/32398,91362343,32,057,001,76194,71,329,76
Liquid Temp
Tliq= 55/131
5/41486,81662418,92,317,891,99210,71,3712,00
15/59697,42382600,22,909,902,50240,51,4817,52

PDF preview unavailable. Download the PDF instead.

kle48gftx 106g5507 r134a 220v 208v 50hz 60hz 08-2025 ds Microsoft Excel für Microsoft 365

Related Documents

Preview SECOP KLE4.8GFTX Compressor Technical Data and Specifications
Comprehensive technical data sheet for the SECOP KLE4.8GFTX compressor. Details include compressor design specifications, general configurations (Conf. 1 & 2), application suitability (LBP, MBP, HBP), electrical data, dimensions, mounting accessories, ambient temperature limits, operation pressure ranges, and detailed performance data under various standard conditions (ASHRAE, EN12900) for both 220-240V/50Hz and 208-230V/60Hz operation. Features R134a and R513A refrigerants.
Preview SECOP KLE4.8GFTX Compressor Technical Data
Technical data sheet for the SECOP KLE4.8GFTX compressor, detailing specifications, configurations, performance tables, and application notes for R134a refrigerant.
Preview SECOP NL7.3MF Compressor Technical Data
Technical data sheet for the SECOP NL7.3MF compressor, detailing specifications, configurations, performance tables, and operating conditions for R134a and R513A refrigerants.
Preview SECOP KLE4.8GFTX Compressor Technical Data Sheet
Detailed technical specifications, dimensions, electrical data, and performance tables for the SECOP KLE4.8GFTX compressor, designed for R134a refrigerant, covering configurations for 220-240V/50Hz and 208-230V/60Hz.
Preview SECOP FRK7.5G Compressor Technical Data
Detailed technical specifications, dimensions, electrical data, and performance tables for the SECOP FRK7.5G compressor, designed for various refrigeration applications using R134a refrigerant.
Preview SECOP KLE4.8GFTX Compressor Technical Data
Technical data sheet for the SECOP KLE4.8GFTX compressor, detailing specifications, configurations, performance tables, and application notes for R134a refrigerant.
Preview Secop KLE4.0GFTX Compressor Technical Data Sheet
Comprehensive technical data, specifications, and performance tables for the Secop KLE4.0GFTX compressor, including details on configurations, dimensions, electrical data, and operating pressure ranges for R134a refrigerant.
Preview SECOP FRK6G Compressor Technical Data Sheet
Detailed technical specifications, dimensions, electrical data, and performance tables for the SECOP FRK6G compressor, designed for R134a refrigerant and operating on 220-240V/50Hz and 208-230V/60Hz power supplies.