Secop FRK10G Compressor

Technical Data Sheet

Single Pack Details

Single Pack FRK10G 220-240V 50Hz / 208-230V 60Hz CSIR

Single Pack Code: 195B4770

Position Title Code Quantity
1 Compressor FRK10G 10665853 1
2 Starting capacitor (80µF 220V, 6.3mm) 117U5001 1
3 Starting relay (QLZ-5.5A, overload protector T0377/L6) 117U7071 1
4 KL accessories 103N1060 1
5 Bolt joint for one compressor | M6 | ø16mm 118-1917 1

Secop GmbH, Lise-Meitner-Straße 29, 24941 Flensburg, Germany. Tel: +49 46149410. www.secop.com

Secop does not assume responsibility for errors in catalogs, brochures, or other printed material. Secop reserves the right to modify its products without prior notice. This also applies to products already ordered, provided that such modifications can be made without subsequent changes to the agreed specifications. All trademarks in this material are the property of their respective companies. Secop and the Secop logo are trademarks of Secop GmbH. All rights reserved.

Technical Data - Compressor FRK10G

Model: FRK10G

Sales Code: 106G5853

Compressor Design

Oil type Polyolester Refrigerant(s) R134a, R513A
Oil viscosity 19,2cSt Displacement 7,7cm³ / 0,47cu.in
Oil quantity 240cm³ / 8,1fl.oz Compressors on pallet 100
Refr. charge - tech. limit 700g / 24,7oz
Free gas volume comp. 1505cm³ / 50,9fl.oz
Weight 9,6kg / 21,2lbs
Motor protection external
Winding resistance main 8,40 (at 25°C)
Winding resistance aux 11,90 (at 25°C)
Max. winding temp. 125°C / 257°F
Max. discharge temp. 130°C / 266°F
Additional note Very good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake. Special design for high refrigerant charge.

General - Configurations with FRK10G

Configuration Conf. 1 Conf. 2
Motor configuration CSIR CSIR
Power supply (nominal) 220-240V/50Hz 208-230V/60Hz
Number of phases 1 1
Voltage range 187-254V 198-253V
Approvals VDE, CB, UL in progress VDE, CB, UL in progress
Starting torque HST HST
Note -/- -/-

Applications with FRK10G

Configuration Conf. 1 Conf. 2
Refrigerant R134a R134a
Application LBP+MBP+HBP LBP+MBP
System cooling fan 3m/s fan 3m/s
Hot gas defrost OK OK
Long interval pull down OK OK

Electrical data - Configurations with FRK10G

Configuration Conf. 1 Conf. 2
Starting device type relay relay
Run capacitor -/- -/-
Start capacitor 80µF 80µF
LRA (locked rotor amps / 4s/ U(N)) 13,5A 13,5A
RLA (rated load amps / 1s/ U(N)) 2,1A 2,1A
Cut in current (U(N)) 12,3A 12,3A

Compressor Dimensions

Dimension Value (mm/in) Diagram Reference
A Height 182mm / 7,17in A
B Height 175mm / 6,89in B
C Length shell 198mm / 7,8in C
D Length w. cover 238mm / 9,37in D
E Width 160mm / 6,3in E

Connectors

Type Diameter (mm/in) Material Horizontal Angle Vertical Angle Position I/h/w (mm/in) Straight tube I. (mm/in)
Suction øi 8,11-8,29 / øi 0,32-0,33 copper 35° +2° 119/73/59 / 4,7/2,9/2,3 14 / 0,5
Discharge øi 6,11-6,29 / øi 0,24-0,25 copper 13° 30° 117/107/66 / 4,6/4,2/2,6 14 / 0,5
Process øi 6,11-6,29 / øi 0,24-0,25 copper 40° -88/101/71 / -3,5/4/2,8 14 / 0,5

Compressor Fixation

Mounting accessories:

Description Code (Single Pack) Code (Multi Pack)
Bolt joint | M6 | ø16mm 118-1917 118-1918
Bolt joint | ø1/4" | ø16mm 118-1946
Bolt joint | ø1/4" | ø19mm 118-1949
Snap-on | ø7,3 | ø16mm 118-1947 118-1919

Application notes: Provision for PE Grounding is located at the PE Stamp on the compressor. Suction gas connector and Process connector can be switched (minor loss of cooling capacity).

Electrical Accessories / Wiring Diagram

Configuration: FRK10G, 220-240V/50Hz

Motor configuration: CSIR

Refrigerant: R134a

Application: LBP+MBP+HBP

Voltage range: 187-254V

Starting torque: HST

Approvals: VDE, CB, UL in progress

Ambient/ machine room temperatures minimum/maximum:

Compressor cooling: fan 3m/s

Operation Pressure Range

A graphical representation of the operation pressure range is provided, showing condensing pressure versus evaporation pressure for continuous and transitory operation.

Components

Component Code
a5: current relay (T0377/L6-S1) 117U7071
c: start capacitor (80µF, 6.3mm) 117U5001
b, d: cover + clamp + screws (5VA-compl.) 103N0600

Alternative components

b, d: 100x cover + clamp + screws (5VA) 103N2060
b, d: cover + clamp + screws (5VA) in bag 103N1060

Performance Tables

The following tables provide detailed performance data for the FRK10G compressor under various conditions for both 220-240V/50Hz and 208-230V/60Hz configurations.

R134a, 220V/50Hz, CSIR, fan 3m/s, VDE, CB, UL in progress

pe pc RGT Tliq Cooling capacity COP EER P1 Ref. mass flow m [kg/h]
[W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [W] [A]
Optimization + standard conditions
-23°C / -10°F 54°C / 130°F 32°C / 90°F 32°C / 90°F 213,7 730 183,9 1,30 4,43 1,12 164,6 1,34 4,15 ASHRAE LBP
-7°C / 20°F 54°C / 130°F 35°C / 95°F 46°C / 115°F 437,6 1494 376,6 1,82 6,22 1,57 240,2 1,61 9,55 ASHRAE MBP
7,2°C / 45°F 54°C / 130°F 35°C / 95°F 46°C / 115°F 765,7 2615 659,0 2,42 8,27 2,08 316,2 1,93 16,99 ASHRAE HBP
-35°C / -31°F 40°C / 104°F 20°C / 68°F 40°C / 104°F 110,9 379 95,4 0,96 3,27 0,82 115,8 1,21 2,43 EN12900 LBP
-10°C / 14°F 45°C / 113°F 20°C / 68°F 45°C / 113°F 381,4 1303 328,3 1,82 6,22 1,57 209,5 1,49 8,93 EN12900 MBP
5°C / 41°F 50°C / 122°F 20°C / 68°F 50°C / 122°F 655,1 2237 563,8 2,27 7,76 1,96 288,3 1,81 16,51 EN12900 HBP

Performance tables

pe pc RGT Tliq Cooling capacity COP EER P1 Ref. mass flow m [kg/h]
[W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [W] [A]
R134a, 220V/50Hz, CSIR, fan 3m/s, VDE, CB, UL in progress
-35°C / -31°F 45°C / 113°F 10°C / 14°F 5°C / 41°F 105,4 360 90,7 0,89 3,05 0,77 117,9 1,22 2,27
-25°C / -13°F 45°C / 113°F 10°C / 14°F 5°C / 41°F 186,0 635 160,1 1,21 4,15 1,05 153,2 1,31 4,03
-15°C / 5°F 45°C / 113°F 10°C / 14°F 5°C / 41°F 312,7 1068 269,1 1,64 5,61 1,41 190,3 1,42 6,82
-10°C / 14°F 45°C / 113°F 10°C / 14°F 5°C / 41°F 395,7 1351 340,6 1,89 6,45 1,63 209,5 1,49 8,66
0°C / 32°F 45°C / 113°F 10°C / 14°F 5°C / 41°F 606,2 2070 521,7 2,43 8,29 2,09 249,6 1,65 13,41
5°C / 41°F 45°C / 113°F 10°C / 14°F 5°C / 41°F 735,6 2512 633,1 2,72 9,29 2,34 270,4 1,74 16,38
15°C / 59°F 45°C / 113°F 10°C / 14°F 5°C / 41°F 1047,8 3578 901,7 3,34 11,40 2,87 313,8 1,92 23,73
R134a, 220V/50Hz, CSIR, fan 3m/s, VDE, CB, UL in progress
-35°C / -31°F 55°C / 131°F 10°C / 14°F 5°C / 41°F 83,8 286 72,1 0,69 2,35 0,59 121,9 1,23 1,99
-25°C / -13°F 55°C / 131°F 10°C / 14°F 5°C / 41°F 157,0 536 135,1 0,99 3,39 0,85 158,3 1,32 3,75
-15°C / 5°F 55°C / 131°F 10°C / 14°F 5°C / 41°F 268,0 915 230,7 1,33 4,56 1,15 200,9 1,46 6,45
-10°C / 14°F 55°C / 131°F 10°C / 14°F 5°C / 41°F 340,2 1162 292,8 1,52 5,18 1,30 224,5 1,55 8,23
0°C / 32°F 55°C / 131°F 10°C / 14°F 5°C / 41°F 522,9 1786 450,0 1,89 6,46 1,63 276,6 1,76 12,79
5°C / 41°F 55°C / 131°F 10°C / 14°F 5°C / 41°F 635,4 2170 546,9 2,08 7,11 1,79 305,0 1,88 15,66
15°C / 59°F 55°C / 131°F 10°C / 14°F 5°C / 41°F 907,7 3100 781,2 2,47 8,45 2,13 366,9 2,16 22,80

PDF preview unavailable. Download the PDF instead.

single-pack-195B4770 GPL Ghostscript 10.00.0

Related Documents

Preview SECOP FRK10G Compressor Technical Data Sheet
Comprehensive technical specifications, performance data, dimensions, and configuration details for the SECOP FRK10G compressor, designed for refrigeration applications using R134a and R513A refrigerants.
Preview SECOP FRK5G Compressor Technical Data Sheet
Detailed technical specifications, performance data, and application information for the SECOP FRK5G compressor, including electrical data, pressure ranges, and dimensions.
Preview SECOP FRK10G Compressor Technical Data Sheet
Comprehensive technical data sheet for the SECOP FRK10G compressor, detailing specifications, configurations, performance data, dimensions, and application notes for R134a refrigerant.
Preview SECOP FRK11G Compressor Technical Data and Specifications
Detailed technical data sheet for the SECOP FRK11G compressor, including specifications, configurations, performance tables, and operational data for R134a refrigerant.
Preview SECOP KLE4.8GFTX Compressor Technical Data
Technical data sheet for the SECOP KLE4.8GFTX compressor, detailing specifications, configurations, performance tables, and application notes for R134a refrigerant.
Preview SECOP FRK6G Compressor Technical Data Sheet
Comprehensive technical data for the SECOP FRK6G compressor, including specifications, configurations, dimensions, electrical data, performance tables, and application notes for R134a refrigerant.
Preview SECOP KLE7.7GFTX Compressor Technical Data Sheet
Comprehensive technical specifications and performance data for the SECOP KLE7.7GFTX compressor, detailing configurations, electrical characteristics, dimensions, operating conditions, and performance tables for R134a and R513A refrigerants.
Preview SECOP FRK5G Compressor Technical Data Sheet
Detailed technical specifications, configurations, electrical data, and performance tables for the SECOP FRK5G compressor, designed for various refrigeration applications using R134a refrigerant.