SECOP FRK5G Compressor Technical Data
General Information
Model | Designation | Sales code |
---|---|---|
FRK5G | Compressor | 106G5463 |
Compressor Design
Property | Value | Property | Value |
---|---|---|---|
Oil type | Polyolester | Refrigerant(s) | R134a, R513A |
Oil viscosity | 19,2 cSt | Displacement | 4 cm³ / 0,24 cu.in |
Oil quantity | 240 cm³ / 8,1 fl.oz | Compressors on pallet | 100 |
Refr. charge - tech. limit | 700g / 24,7oz | ||
Free gas volume comp. | 1560 cm³ / 52,7 fl.oz | ||
Weight | 8,9kg / 19,6lbs | ||
Motor protection | external | ||
Winding resistance main | 13,1 Ω (at 25°C) | ||
Winding resistance aux | 25,3 Ω (at 25°C) | ||
Max. winding temp. | 125°C / 257°F | ||
Max. discharge temp. | 130°C / 266°F | ||
Additional note | Very good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake. Special design for high refrigerant charge. |
General Configurations with FRK5G
Configuration | Conf. 1 | Conf. 2 |
---|---|---|
Motor configuration | CSIR | CSIR |
Power supply (nominal) | 220-240V/50Hz | 208-230V/60Hz |
Number of phases | 1 | 1 |
Voltage range | 187-254V | 198-253V |
Approvals | VDE, CB, UL in progress | |
Starting torque | HST | HST |
Note | Electrical equipment is included and pre-assembled to compressor. |
Applications with FRK5G
Parameter | Conf. 1 | Conf. 2 |
---|---|---|
Refrigerant | R134a | R134a |
Application | LBP+MBP+HBP | LBP+MBP |
System cooling | static | static |
Hot gas defrost | OK | OK |
Long interval pull down | OK | OK |
Electrical Data - Configurations with FRK5G
Parameter | Conf. 1 | Conf. 2 |
---|---|---|
Starting device type | relay | relay |
Run capacitor | -/- | -/- |
Start capacitor | 80μF | 80μF |
LRA (locked rotor amps / 4s/ U(N)) | 10,2A | 10,2A |
RLA (rated load amps / 1s/ U(N)) | 1,4A | 1,4A |
Cut in current (U(N)) | 10,2A | 10,2A |
Compressor Dimensions and Fixation
Dimension | Value (mm) | Value (in) | Dimension | Value (mm) | Value (in) |
---|---|---|---|---|---|
A Height | 182 | 7,17 | Connectors - Diameter (inside, outside) | øi 6,16-6,24 (øi 0,24-0,25) | øi 5,1-5,2 (øi 0,2-0,2) |
B Height | 175 | 6,89 | Connectors - Material | copper | copper |
C Length shell | 198 | 7,8 | Horizontal angle | +2° | 35° |
D Length w. cover | 238 | 9,37 | Vertical angle | +2° | 30° |
E Width | 160 | 6,3 | Position I/h/w | 119/73/59 | 4,7/2,9/2,3 |
Straight tube I. | 14 | 0,5 |
Compressor Fixation: Details on baseplate dimensions, bolt joints, and snap-on mounting accessories are provided in diagrams and tables, specifying bolt sizes and part numbers (e.g., Bolt joint | M6 | Ø16mm - 118-1917).
Performance Data (R134a, 220V/50Hz, CSIR, static)
Conditions | Cooling Capacity | COP | EER | Power Consumption | Ref. mass flow | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pe [°C] | pc [°C] | [W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | [kg/h] | |||
-23 | 54 | 98,4 | 336 | 84,7 | 1,11 | 3,79 | 0,96 | 88,6 | 0,91 | 1,91 | ASHRAE LBP | ||
-7 | 54 | 215,0 | 734 | 185,1 | 1,72 | 5,86 | 1,48 | 125,3 | 1,00 | 4,69 | ASHRAE MBP | ||
7,2 | 54 | 386,4 | 1320 | 332,5 | 2,50 | 8,54 | 2,15 | 154,5 | 1,07 | 8,57 | ASHRAE HBP | ||
-35 | 40 | 44,6 | 152 | 38,4 | 0,68 | 2,34 | 0,59 | 65,1 | 0,86 | 0,98 | EN12900 LBP | ||
-10 | 45 | 185,6 | 634 | 159,7 | 1,69 | 5,77 | 1,45 | 109,8 | 0,96 | 4,34 | EN12900 MBP | ||
5 | 50 | 329,2 | 1124 | 283,3 | 2,29 | 7,82 | 1,97 | 143,8 | 1,04 | 8,30 | EN12900 HBP |
Performance Tables
Conditions | Cooling Capacity | COP | EER | Power Consumption | Ref. mass flow | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pe [°C] | pc [°C] | [W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | [kg/h] | |||
-35 | -31 | 42,1 | 144 | 36,2 | 0,65 | 2,22 | 0,56 | 64,8 | 0,86 | 0,91 | cond. pressure pc= 45/113 | ||
-25 | -13 | 84,2 | 287 | 72,4 | 1,02 | 3,47 | 0,87 | 82,8 | 0,90 | 1,82 | return gas temp. RGT=32/90 | ||
-15 | 5 | 149,6 | 511 | 128,8 | 1,48 | 5,07 | 1,28 | 100,8 | 0,94 | 3,26 | liquid temp Tliq= 45/113 | ||
-10 | 14 | 192,5 | 657 | 165,7 | 1,75 | 5,99 | 1,51 | 109,8 | 0,96 | 4,21 | |||
0 | 32 | 301,6 | 1030 | 259,6 | 2,36 | 8,06 | 2,03 | 127,8 | 1,00 | 6,67 | |||
5 | 41 | 369,0 | 1260 | 317,5 | 2,70 | 9,21 | 2,32 | 136,8 | 1,02 | 8,21 | |||
15 | 59 | 532,1 | 1817 | 457,9 | 3,44 | 11,74 | 2,96 | 154,9 | 1,08 | 12,05 | |||
-35 | -31 | 34,3 | 117 | 29,6 | 0,56 | 1,91 | 0,48 | 61,4 | 0,86 | 0,82 | cond. pressure pc= 55/131 | ||
-25 | -13 | 71,6 | 244 | 61,6 | 0,84 | 2,88 | 0,73 | 84,8 | 0,91 | 1,71 | return gas temp. RGT=32/90 | ||
-15 | 5 | 128,5 | 439 | 110,6 | 1,20 | 4,08 | 1,03 | 107,5 | 0,95 | 3,09 | liquid temp Tliq= 55/131 | ||
-10 | 14 | 165,7 | 566 | 142,6 | 1,40 | 4,77 | 1,20 | 118,5 | 0,98 | 4,01 | |||
0 | 32 | 260,7 | 890 | 224,3 | 1,86 | 6,35 | 1,60 | 140,1 | 1,03 | 6,38 | |||
5 | 41 | 319,6 | 1091 | 275,0 | 2,12 | 7,24 | 1,83 | 150,6 | 1,06 | 7,87 | |||
15 | 59 | 463,0 | 1581 | 398,4 | 2,70 | 9,23 | 2,33 | 171,3 | 1,13 | 11,63 |
Operation Pressure Range
Graphical representation of the operation pressure range, showing condensing pressure versus evaporation pressure for continuous and transitory operation.
Electrical Accessories / Wiring Diagram
Diagrams illustrating electrical accessories and wiring for the compressor, including components like current relay (a5) and start capacitor (c).