RF1A-OT - Wireless Receiver

with RFRP-HW-OT

Operating Instructions

Contents

Important: Keep this document. Prior to operation, it is necessary to complete all required settings described in this section.

1. Specifications & Wiring

Specifications:

Internal Wiring Diagram Description:

The internal wiring diagram for the RF1A-OT shows terminals labeled L, N, OT, ON, COM, OFF. The MAINS SUPPLY connects to terminals L and N. For mains voltage output, terminals L and 2 must be electrically linked. Important: Do not connect Mains Voltage to OpenTherm® terminals.

CAUTION!

Before commencing any work on the electrical connections, you must first disconnect the device from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed. Only qualified electricians or authorised service staff are permitted to open the terminal box. There are parts that carry mains voltage behind the cover. The terminal box must not be left unsupervised when open. (Prevent non specialists and especially children from gaining access to it.) Ensure that this wireless enabled receiver is installed 1 metre from any metallic object, television, radio or wireless internet transmitter.

2. Mounting

The RF1A-OT receiver should be wall mounted in an area within 20 metres distance of the wireless thermostat.

It is important that the receiver is mounted more than 1 metre away from metal objects, as this will affect communication with the thermostat.

The receiver should also be installed at least 1 metre from any electronic devices such as radio, TV, microwave, or wireless network adaptor.

The unit can be fitted to:

  1. Recessed conduit boxes
  2. Surface mounting boxes

3. Installation

Slacken the fastening screw on the bottom of the receiver with a Phillips screwdriver. The receiver is hinged and can be opened 180 degrees. Mount the unit as described in section 2. Wire the unit as described in section 1. Close the receiver and tighten the fastening screw.

4. Button / LED Description

The RF1A-OT receiver features several buttons and LEDs for operation and status indication.

Buttons:

LED Indicators:

Wireless Connect Process:

Once voltage has been applied, press the Connect button to initialise the pairing process with the wireless thermostat. Once pressed, the red and green LEDs will begin to flash.

Manual Override:

Pressing the Manual override button will manually control the heating system.

LED Description Table:

Status Green LED Red LED
OT Connection Normal Operation
RF1A-OT On ON OFF - will flash when communicating via RF
RF1A-OT Off OFF ON - will flash when communicating via RF
OT Communication Error
RF1A-OT On Constant Flash OFF
RF1A-OT Off Constant Flash ON
RF Communication Error
RF1A-OT On ON Constant Flash
RF1A-OT Off OFF Constant Flash
Summary
RF Communication Error OFF or ON Constant Flash
OT Communication Error Constant Flash OFF or ON
Normal Operation RF1A On ON OFF or Flashing
Normal Operation RF1A Off OFF ON or Flashing

5. Resetting the RF1A-OT Receiver

To reset the RF1A-OT receiver, press the RESET button located on the side of the receiver. The RF1A-OT receiver is now reset.

6. Connecting the RFRP-HW-OT Thermostat to an RF1A-OT Receiver

Note: If you are installing a CP4-HW-OT, the RFRP-HW-OT thermostat and the RF1A-OT receiver will have a pre-established RF connection, so it is not necessary to carry out the RF connection process below.

On the RF1A-OT Receiver:

Press the Connect button. The red light will begin to flash.

On the RFRP-HW-OT Thermostat:

  1. Press the Connect button.
  2. The thermostat will show "nOE" followed by "---".
  3. Once an RF connection has been established, the thermostat will show 'r01' on the LCD screen.
  4. Press the 'OK' button to finish the process.

The thermostat is now connected to the RF1A-OT receiver.

7. Disconnecting the RFRP-HW-OT Thermostat from an RF1A-OT Receiver

This can be done from either the thermostat or the receiver.

7.1 On the RFRP-HW-OT Thermostat:

  1. Press the Connect button. The thermostat will begin to search through the RF channels.
  2. Press and hold the 'Copy' button for 10 seconds. 'Adr' will appear on the screen of the thermostat.
  3. Press the 'OK' button twice to complete the unpairing process.

The thermostat RFRP-HW-OT is now disconnected from the receiver RF1A-OT.

7.2 On the RF1A-OT Receiver:

  1. Press the Connect button; the red light will flash. (Red & green lights if using as a hub receiver).
  2. Press and hold the Connect button for about 10 seconds; the receiver will then stop flashing.

The RF connection is now cleared.

PDF preview unavailable. Download the PDF instead.

20191011 RF1A-OT RFRP-HW-OT OpIns JW Adobe Illustrator CC 23.1 (Macintosh) Adobe PDF library 15.00

Related Documents

Preview EPH Controls RF1A-OT Wireless Receiver & RFRP-HW-OT Thermostat Operating Instructions
Detailed operating instructions for the EPH Controls RF1A-OT Wireless Receiver and RFRP-HW-OT Thermostat, covering specifications, mounting, installation, wiring, button functions, LED indicators, and pairing/unpairing procedures.
Preview EPH Controls RF1A-OT Wireless Receiver Operating Instructions
Comprehensive operating instructions for the EPH Controls RF1A-OT Wireless Receiver, detailing specifications, mounting, installation, button/LED descriptions, and pairing/unpairing procedures with the RFRP-HW-OT thermostat.
Preview EPH Controls R27-RF 2 Zone RF Programmer Installation Instructions
Comprehensive installation guide for the EPH Controls R27-RF 2 Zone RF Programmer, detailing setup, wiring, programming, and frost protection features for optimal home heating control.
Preview RFRP-HW-OT Wireless Cylinder Thermostat Installation Instructions
Comprehensive installation guide for the EPH Controls RFRP-HW-OT wireless cylinder thermostat, detailing safety precautions, mounting procedures, product specifications, and manufacturer contact information.
Preview EPH Controls RF1A Wireless Receiver and TRFPi2 Thermostat Operating Instructions
Comprehensive operating instructions for the EPH Controls RF1A Wireless Receiver and TRFPi2 Thermostat, covering specifications, wiring, mounting, installation, button/LED descriptions, pairing, and disconnection procedures.
Preview EPH Controls CP4 Programmable RF Thermostat & Receiver - Simple & User Friendly
Discover the EPH Controls CP4, a user-friendly, programmable RF thermostat and receiver designed for simple and efficient heating and hot water control. Features include a large LCD, ergonomic buttons, multi-zone capability with OpenTherm, and a contemporary design. Enjoy cost-effective energy savings and easy installation with pre-paired components.
Preview EPH CP4V2 Programmable RF Thermostat & Receiver: Installation and Operation Guide
Comprehensive guide for installing and operating the EPH Controls CP4V2 Programmable RF Thermostat and RF1B Wireless Receiver, covering setup, features, and system integration for efficient home heating control.
Preview EPH Controls CP4D Programmable RF Thermostat & Receiver Installation and Operation Guide
Comprehensive guide for installing and operating the EPH Controls CP4D programmable RF thermostat and receiver system, detailing setup, features, and system integration.