RF1A-OT - Wireless Receiver
with RFRP-HW-OT
Operating Instructions
Contents
- 1. Specifications & Wiring
- 2. Mounting
- 3. Installation
- 4. Button / LED Description
- 5. Resetting the RF1A-OT Receiver
- 6. Connecting the RFRP-HW-OT Thermostat to an RF1A-OT Receiver
- 7. Disconnecting the RFRP-HW-OT Thermostat from an RF1A-OT Receiver
Important: Keep this document. Prior to operation, it is necessary to complete all required settings described in this section.
1. Specifications & Wiring
Specifications:
- Power Supply: 200 - 240Vac, 50-60Hz
- Contact Rating: 250 Vac 10(3)A
- Ambient Temp: 0~45°C
- Automatic Action: Type 1.C.Q
- Class II appliance
- Pollution degree: Pollution degree 2
- Rated Impulse Voltage: Resistance to voltage surge 2500V; as per EN 60730
- IP Rating: IP20
Internal Wiring Diagram Description:
The internal wiring diagram for the RF1A-OT shows terminals labeled L, N, OT, ON, COM, OFF. The MAINS SUPPLY connects to terminals L and N. For mains voltage output, terminals L and 2 must be electrically linked. Important: Do not connect Mains Voltage to OpenTherm® terminals.
CAUTION!
Before commencing any work on the electrical connections, you must first disconnect the device from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed. Only qualified electricians or authorised service staff are permitted to open the terminal box. There are parts that carry mains voltage behind the cover. The terminal box must not be left unsupervised when open. (Prevent non specialists and especially children from gaining access to it.) Ensure that this wireless enabled receiver is installed 1 metre from any metallic object, television, radio or wireless internet transmitter.
2. Mounting
The RF1A-OT receiver should be wall mounted in an area within 20 metres distance of the wireless thermostat.
It is important that the receiver is mounted more than 1 metre away from metal objects, as this will affect communication with the thermostat.
The receiver should also be installed at least 1 metre from any electronic devices such as radio, TV, microwave, or wireless network adaptor.
The unit can be fitted to:
- Recessed conduit boxes
- Surface mounting boxes
3. Installation
Slacken the fastening screw on the bottom of the receiver with a Phillips screwdriver. The receiver is hinged and can be opened 180 degrees. Mount the unit as described in section 2. Wire the unit as described in section 1. Close the receiver and tighten the fastening screw.
5. Resetting the RF1A-OT Receiver
To reset the RF1A-OT receiver, press the RESET button located on the side of the receiver. The RF1A-OT receiver is now reset.
6. Connecting the RFRP-HW-OT Thermostat to an RF1A-OT Receiver
Note: If you are installing a CP4-HW-OT, the RFRP-HW-OT thermostat and the RF1A-OT receiver will have a pre-established RF connection, so it is not necessary to carry out the RF connection process below.
On the RF1A-OT Receiver:
Press the Connect button. The red light will begin to flash.
On the RFRP-HW-OT Thermostat:
- Press the Connect button.
- The thermostat will show "nOE" followed by "---".
- Once an RF connection has been established, the thermostat will show 'r01' on the LCD screen.
- Press the 'OK' button to finish the process.
The thermostat is now connected to the RF1A-OT receiver.
7. Disconnecting the RFRP-HW-OT Thermostat from an RF1A-OT Receiver
This can be done from either the thermostat or the receiver.
7.1 On the RFRP-HW-OT Thermostat:
- Press the Connect button. The thermostat will begin to search through the RF channels.
- Press and hold the 'Copy' button for 10 seconds. 'Adr' will appear on the screen of the thermostat.
- Press the 'OK' button twice to complete the unpairing process.
The thermostat RFRP-HW-OT is now disconnected from the receiver RF1A-OT.
7.2 On the RF1A-OT Receiver:
- Press the Connect button; the red light will flash. (Red & green lights if using as a hub receiver).
- Press and hold the Connect button for about 10 seconds; the receiver will then stop flashing.
The RF connection is now cleared.