RF1A-OT Wireless Receiver Operating Instructions

⚠️

CAUTION! Before commencing any work on the electrical connections, you must first disconnect the device from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed. Only qualified electricians or authorised service staff are permitted to open the terminal box. There are parts that carry mains voltage behind the cover. The terminal box must not be left unsupervised when open. (Prevent non specialists and especially children from gaining access to it.) Ensure that this wireless enabled receiver is installed 1 metre from any metallic object, television, radio or wireless internet transmitter.

Contents

1. Specifications & Wiring

Specifications

Wiring Diagram

The internal wiring diagram for the RF1A-OT shows connections for the Mains Supply: Live (L), Neutral (N), and OpenTherm (OT). Terminals are numbered 1, 2, 3. Terminal 1 is L, Terminal 2 is N, Terminal 3 is OT. A note indicates that if mains voltage output is required, terminals L and 2 must be electrically linked. A critical warning states not to connect mains voltage to OpenTherm terminals.

Mains Supply Connection

Connect the mains supply to the appropriate terminals (L and N). Ensure all connections are secure and that mains voltage is not present at the OpenTherm terminals.

2. Mounting

The RF1A-OT receiver should be wall mounted in an area within 20 metres distance of the wireless thermostat. It is important that the receiver is mounted more than 1 metre away from metallic objects, televisions, radios, or wireless internet transmitters, as these can affect communication. The receiver should also be installed at least 1 metre from any other electronic devices such as radios, TVs, microwaves, or wireless network adaptors.

3. Installation

Slacken the fastening screw on the bottom of the receiver with a philips screwdriver. The receiver is hinged and can be opened 180 degrees. Mount the unit as described in Section 2. Wire the unit as described in Section 1. Close the receiver and tighten the fastening screw.

4. Button / LED Description

Controls

Indicators

LED Status Descriptions

OT Connection Normal Operation

StatusGreen LEDRed LED
RF1A-OT OnONOFF - will flash when communicating via RF
RF1A-OT OffOFFON - will flash when communicating via RF

OT Communication Error

StatusGreen LEDRed LED
RF1A-OT OnConstant FlashOFF
RF1A-OT OffConstant FlashON

RF Communication Error

StatusGreen LEDRed LED
RF1A-OT OnONConstant Flash
RF1A-OT OffOFFConstant Flash

Summary

StatusGreen LEDRed LED
RF Communication ErrorOFF or ONConstant Flash
OT Communication ErrorConstant FlashOFF or ON
Normal Operation RF1A OnONOFF or Flashing
Normal Operation RF1A OffOFFON or Flashing

5. Resetting the RF1A-OT Receiver

Press the [Reset Button] located on the side of the receiver. The RF1A-OT receiver is now reset.

6. Connecting the RFRP-HW-OT Thermostat to an RF1A-OT Receiver

Note: If you are installing a CP4-HW-OT, the RFRP-HW-OT thermostat and the RF1A-OT receiver will have a pre-established RF connection, so it is not necessary to carry out the RF connection process below.

On the RF1A-OT Receiver:

Press the [Connect Button]. The red light will begin to flash.

On the RFRP-HW-OT Thermostat:

Press the [Connect Button]. The thermostat will show "nOE" followed by "---". Once an RF connection has been established, the thermostat will show 'r01' on the LCD screen. Press the 'OK' button to finish the process. The thermostat is now connected to the RF1A-OT receiver.

7. Disconnecting the RFRP-HW-OT Thermostat from an RF1A-OT Receiver

This can be done from either the thermostat or the receiver.

7.1 On the RFRP-HW-OT Thermostat:

Press the [Connect Button]. The thermostat will begin to search through the RF channels. Press and hold the 'Copy' button for 10 seconds. 'Adr' will appear on the screen of the thermostat. Press the 'OK' button twice to complete the unpairing process. The thermostat RFRP-HW-OT is now disconnected from the receiver RF1A-OT.

7.2 On the RF1A-OT Receiver:

Press the [Connect Button]; the red light will flash. (Red & green lights may flash if used as a hub receiver). Press and hold the [Connect Button] for approximately 10 seconds. The RF connection is now cleared.

EPH Controls Contact Information:

EPH Controls Ireland: technical@ephcontrols.com | www.ephcontrols.com

EPH Controls UK: technical@ephcontrols.com | www.ephcontrols.co.uk

Document Reference: 20221005_RF1A_OT_RFRP-HW-OT_OpIns_PK

Models: RF1A-OT Wireless Receiver, RF1A-OT, Wireless Receiver, Receiver

File Info : application/pdf, 2 Pages, 222.48KB

PDF preview unavailable. Download the PDF instead.

20221005 RF1A-OT RFRP-HW-OT OpIns PK Email

References

Adobe PDF library 16.07 Adobe Illustrator 26.5 (Macintosh)

Related Documents

Preview EPH Controls RF1A-OT Wireless Receiver & RFRP-HW-OT Thermostat Operating Instructions
Detailed operating instructions for the EPH Controls RF1A-OT Wireless Receiver and RFRP-HW-OT Thermostat, covering specifications, mounting, installation, wiring, button functions, LED indicators, and pairing/unpairing procedures.
Preview EPH Controls RF1A-OT Wireless Receiver & RFRP-HW-OT Thermostat: Operating Instructions
Detailed operating instructions for the EPH Controls RF1A-OT Wireless Receiver and RFRP-HW-OT thermostat system. Covers specifications, mounting, installation, pairing, and troubleshooting for efficient heating control.
Preview RFRP-HW-OT Wireless Cylinder Thermostat Installation Instructions
Comprehensive installation guide for the EPH Controls RFRP-HW-OT wireless cylinder thermostat, detailing safety precautions, mounting procedures, product specifications, and manufacturer contact information.
Preview EPH Controls RF1A Wireless Receiver and TRFPi2 Thermostat Operating Instructions
Comprehensive operating instructions for the EPH Controls RF1A Wireless Receiver and TRFPi2 Thermostat, covering specifications, wiring, mounting, installation, button/LED descriptions, pairing, and disconnection procedures.
Preview EPH Controls CP4 Programmable RF Thermostat & Receiver - Simple & User Friendly
Discover the EPH Controls CP4, a user-friendly, programmable RF thermostat and receiver designed for simple and efficient heating and hot water control. Features include a large LCD, ergonomic buttons, multi-zone capability with OpenTherm, and a contemporary design. Enjoy cost-effective energy savings and easy installation with pre-paired components.
Preview EPH CP4V2 Programmable RF Thermostat & Receiver: Installation and Operation Guide
Comprehensive guide for installing and operating the EPH Controls CP4V2 Programmable RF Thermostat and RF1B Wireless Receiver, covering setup, features, and system integration for efficient home heating control.
Preview EPH Controls RFRB RF Room Thermostat: Operating Instructions & Setup Guide
Comprehensive operating instructions for the EPH Controls RFRB RF Room Thermostat. Learn how to install, connect, and use your thermostat for efficient heating control. Includes setup, functions, and troubleshooting.
Preview EPH Controls CP4D Programmable RF Thermostat & Receiver Installation and Operation Guide
Comprehensive guide for installing and operating the EPH Controls CP4D programmable RF thermostat and receiver system, detailing setup, features, and system integration.