Wallbox Pulsar & Pulsar Plus Installation Guide
General Specifications
PULSAR & PULSAR PLUS
- A - Charging Mode (IEC 61851-1): Modo de carga (IEC 61851-1)
- B - Dimensions without cable: Dimensiones sin cable: 166x163x82 mm
- C - Weight without cable: Peso sin cable: 1 kg
- D - Operating Temperature: Temperatura de funcionamiento: -25 °C to 40 °C
- E - Storage Temperature: Temperatura de almacenamiento: -40 °C to 70 °C
- F - Standards: Estándares: CE mark (LVD 2014/35/EU, EMCD 2014/30/EU), IEC 61851-1, IEC 61851-21-2, IEC 62196-2
Electrical Specifications
PULSAR & PULSAR PLUS
Specification | Pulsar (1P) | Pulsar Plus (3P) |
---|---|---|
A - Charging Power | 7.4 kW | 11 kW / 22 kW |
B - Rated Voltage AC ± 10% | 230 V | 400 V |
C - Cable Section | 5 x 6 mm² (Pulsar) | 5 x 10 mm² (Pulsar Plus) |
D - Rated Frequency | 50 Hz / 60 Hz | |
E - Protection Rating | IP54 / IK08 | |
F - Overvoltage Category | CAT III | |
G - External RCCB required per local regulations | Type A or Type B | |
H - Residual current protection | AC 30mA / DC 6mA | |
I - Protection against electric shock | CLASS I |
Part Number Structure
The part number structure is as follows: XXXX-X-X-X-X-XXX
1 - MODEL: PULSAR, PULSAR PLUS
2 - CABLE: 0 - Standard, 5 - 5 m, M - 7 m
3 - CONNECTOR: 1 - Type 1, 2 - Type 2
4 - POWER: 2 - 7.4 kW (32 A) 1P, 3 - 11 kW (16 A) 3P, 4 - 22 kW (32 A) 3P
5 - ADDITIONAL FEATURE: P - Power Sharing, 9 - Residual Current Detection (AC 30mA / DC 6mA), F - Residual Current Detection (AC 30mA / DC 6mA) + Earthing protection
6 - CUSTOM: XX1 - White, XX2 - Black
Safety Warnings
- A. Flying debris, risk of injury.
- B. Risk of electric shock. Disconnect and wait 10 mins.
- C. Caution.
- D. Sharp element, risk of injurious cuts.
- E. Ground earth connection required.
- F. Special waste treatment.
Required Tools
- A. Hammer
- B. Electric Drill
- C. Pencil
- D. Screwdrivers
- E. Cutting Pliers
- F. Torx T9
- G. Measuring Tape
- H. Utility Knife
Mounting Parts
Included Mounting Parts:
- I. Grommet
- J. Anchors ø8 x 40 mm
- K. Screws ø6 x 50 mm
- L. Protective Caps
- M. Opening Tool
- N. Screws ø5 x 40 mm
- O. Screw ø3 x 6 mm
1 - Drilling
A. Place the drilling template on the wall and mark the three fixing points.
B. Drill holes where the fixing points are marked.
C. Insert the anchor screws into the fixing holes.
2.a - Lower Connection
A. Fix the device on the wall by inserting the screws and then the protective caps.
B. Make an incision on the rubber grommet for the power supply cable.
C. Insert the power supply cable through the grommet.
2.b - Rear Connection
A. Cut the thin plastic area on the back of the charger, and insert the grommet.
B. Make an incision on the grommet and insert the power supply cable.
C. Fix the device on the wall by inserting the screws and then the protective caps.
3 - Electrical Wiring
A. Single Phase Set-up
B. Three-Phase Set-up
C. Three-Phase No Neutral
D. Bi-phase No Neutral
E. Bi-phase Set-up
For Pulsar, tighten the terminal screws up to 0.9 Nm. Do not over-tighten. Ensure that the maximum voltage is less than 264 V between L & N inputs.
See Earthing Protection section for installations with PME.
Earthing Protection
This section outlines the information for installation of Wallbox Pulsar Plus in the UK region.
Part Numbers Affected: PLP1-X-X-2-F-XXX-A
In the UK region, the PME system with an incoming earthing point is widely used by residential and business electricity consumers. The RCCB does not provide protection against open circuit PME faults, so touch voltage hazards could occur without triggering a disconnection of the mains electricity supply to the building.
To follow and be compliant with the regulations specified by IET in clause 722.411.4.1(iv), Wallbox Pulsar Plus uses a technology that enables you to directly connect your charger to a PME supply.
The Wallbox Pulsar Plus UK charger now includes a safety monitoring system to detect potential earth-neutral faults. If faults are detected in the circuit, the charge cycle ends thus isolating the vehicle from the power supply. This removes the risk of touching the vehicle and a potential shock if earth-neutral fault is present.
Wiring Diagram:
L1 L2 L3 N PE
L
PE
N
4 - Closing the Charger
A. Position the current selector to an appropriate setting. Positions 0, 8 and 9 reserved for Power Sharing Smart.
B. Attach the open end of the communications cable to the connector. Close the device by clipping the cover.
C. Tighten the security screw. Recommended tightening torque 0.7 Nm +/- 10%.
5 - Installing the Plug Holder
A. Place the plug holder on the wall and mark the fixing points.
B. Drill holes where the fixing points are marked.
C. Insert the anchor screws into the fixing holes. Fix the device on the wall by inserting and tightening the screws.
6 - Registering the Charger
A. Locate the Serial Number (SN) and the UID of your charger.
B. Download the my Wallbox App and register.
C. Add your charger by introducing the requested data.
D. Configure the device in the advanced settings.
E. Select the Earthing type manually. Remember to unlink the charger if you are the installer.
F. Check for latest updates.
See the OCPP Activation Manual at https://support.wallbox.com/en/knowledge-base/ocpp_activation_manual/