LG KSSAC091A R32 Single Zone Mega Wall Mount Air Conditioner
Product Specifications and Details
Product Identification
Model System: KSSAC091A
Outdoor Unit (ODU) Model: KUSAC091A
Indoor Unit (IDU) Model: KNSAC091A
Type: R32 Single Zone Mega Wall Mount Air Conditioner
Performance Specifications
Cooling
Cooling Capacity (Min~Rated~Max) | 3,070 ~ 9,000 ~ 11,980 Btu/h |
SEER2 | 21.0 |
EER2 | 12.50 |
Heating
Heating Capacity (Min~Rated~Max) | 3,070 ~ 10,900 ~ 12,930 Btu/h |
HSPF2 | 9.810 |
Max. Heating @ Indoor 70°F DB, Outdoor 19°F DB / 17°F WB | 9.2 |
Max. Heating @ Indoor 70°F DB, Outdoor 6°F DB / 5°F WB | 7,700 |
Electrical Specifications
Power Supply | 208-230V / 60Hz / 1Ø |
MOP (Max. Overcurrent Protection) | 15 A |
MCA (Min. Circuit Ampacity) | 10 A |
Cooling Rated Amps | 5.2 A |
Heating Rated Amps | 7.3 A |
Compressor Amps | 6.7 A |
Fan Motor (IDU + ODU) | 0.4 + 0.6 A |
Cooling Power Input (Min~Rated~Max @95°F) | 0.2 ~ 0.72 ~ 1.33 kW |
Heating Power Input (Min~Rated~Max @47°F) | 0.195 ~ 0.838 ~ 1.4 kW |
Piping Specifications
Liquid Line (O.D.) | 1/4 in. |
Vapor Line (O.D.) | 3/8 in. |
Additional Refrigerant | 0.16 oz./ft. |
Min. / Max. Pipe Length | 9.8 / 49.2 ft. |
Piping Length (no add'l refrig.) | 24.6 ft. |
Max. Elevation | 23 ft. |
Features
- 24-Hour on/off timer
- Two-way (up/down) auto swing
- Built-in Wi-Fi via ThinQ™ app
- Inverter (variable speed compressor)
- Self-cleaning indoor coil
- Smart Care
- Auto changeover
- Auto restart
- Jet cool/Jet heat
- Sleep mode
- Smart Diagnosis
- Ultra-quiet operation
Included Accessories & Controller Options
Included Accessory: Wireless Remote Controller (Model: AKB76044207)
Controller Options: MultiSITE™ CRC* Controllers, Standard III Remote Controllers, Deluxe Remote Controller, Simple Remote Controllers, Dry Contacts
Operating Range
Outdoor Unit
Cooling (°F DB) | 14 ~ 118 |
Heating (°F WB) | 5 ~ 65 |
Indoor Unit
Cooling (°F WB) | 53 ~ 75 |
Heating (°F DB) | 60 ~ 86 |
System Data
Refrigerant Type | R32 |
Refrigerant Control | EEV |
Refrigerant Charge | 1.54 lbs. |
ODU Sound Pressure (Cooling / Heating) | 50 / 50 dB[A] |
IDU Sound Pressure (Cooling H/M/L/Sleep) | 42 / 36 / 28 / 21 dB[A] |
IDU Sound Pressure (Heating H/M/L) | 42 / 36 / 28 dB[A] |
ODU Net / Shipping Weight | 55.3 / 60 lbs. |
IDU Net / Shipping Weight | 19.2 / 22.0 lbs. |
Heat Exchanger Coating | GoldFin™ |
Fan Specifications
ODU Type | Propeller |
IDU Type | Cross Flow |
Fan Speeds (Fan/Cool/Heat) | 6 / 6 / 6 |
Quantity (ODU + IDU) | 1 + 1 |
Motor/Drive | Brushless Digitally Controlled/Direct |
ODU Max. Air Flow Rate | 953 CFM |
IDU Air Flow (Cooling, Max/H/M/L) | 459 / 353 / 264 / 148 CFM |
IDU Air Flow (Heating, Max/H/M/L) | 459 / 353 / 254 / 198 CFM |
Dehumidification | 2.32 pts./hr. |
Diagram Descriptions
Outdoor Unit (ODU) Dimensions
The Outdoor Unit (ODU) KUSAC091A has a rectangular prism shape. Key dimensions include:
- Width: Approximately 28-7/32 inches (717 mm)
- Height: Approximately 19-1/2 inches (495 mm)
- Depth: Approximately 10-1/2 inches (267 mm)
- Features include an air outlet on the top/side, a control box, and service valve covers. Pipe and wiring connections are located on the side.
Indoor Unit (IDU) Dimensions and Features
The Indoor Unit (IDU) KNSAC091A is a wall-mounted unit with a sleek, rectangular design. Key dimensions and features include:
- Width: Approximately 32-15/16 inches (837 mm)
- Height: Approximately 12-1/8 inches (308 mm)
- Depth: Approximately 7-7/16 inches (189 mm)
- Air intake is located on the front and sides.
- Air outlet is located at the top.
- Includes holes for refrigerant piping, drain piping, and wiring.
- Features a display/remote controller signal receiver on the front.
- Installation plate is provided for mounting.
- Airflow direction can be controlled up/down and left/right.
Notes
- Acceptable operating voltage: 187V-253V.
- Piping lengths are equivalent.
- Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
- Communication/power cable from ODU to IDU must be field supplied (min. 4-conductor, 14 AWG, shielded or unshielded, grounded to ODU chassis only) and comply with local/national codes.
- Refer to Engineering Manual for sensible and latent capacities.
- Power wiring cable size must comply with applicable local and national codes.
- Indoor unit comes with a dry helium charge.
- Data rated at 0 ft. above sea level, with 24.6 ft. of refrigerant line and 0 ft. level difference between units.
- Must follow installation instructions in the applicable LG installation manual.
Certifications and Compliance
This product is designed to meet ENERGY STAR® criteria when matched with appropriate coil components. Visit www.energystar.gov for details.
AHRI Certified® for Unitary Small HP (AHRI Standard 210/240). Certification applies only when the complete system is listed with AHRI.