LG LQ120HV4 Single Zone Low Wall Console
Product Details
Model: LQ120HV4
Type: Single Zone Low Wall Console
Outdoor Unit (ODU): LUU127HV
Indoor Unit (IDU): LQN120HV4
Performance Specifications
Cooling
Parameter | Value |
---|---|
Cooling (Min~Rated~Max, Btu/h) | 4,500 ~ 10,200 ~ 13,460 |
SEER2 | 20.8 |
EER2 | 12.6 |
Heating
Parameter | Value |
---|---|
Heating (Min~Rated~Max, Btu/h) | 5,970 ~ 13,000 ~ 15,000 |
HSPF2 | 10.2 |
Nominal Test Conditions
Condition | Indoor | Outdoor |
---|---|---|
Cooling | 80°F DB / 67°F WB | 95°F DB / 75°F WB |
Heating | 70°F DB / 60°F WB | 47°F DB / 43°F WB |
Operating Range
Unit | Parameter | Range |
---|---|---|
Outdoor Unit | Cooling (°F DB) | 0 to 118 |
Heating (°F WB) | -4 to 64 | |
Indoor Unit | Cooling (°F WB) | 57 to 77 |
Heating (°F DB) | 59 to 81 |
Electrical Specifications
Parameter | Value |
---|---|
Power Supply¹ (V/Hz/Ø) | 208-230/60/1 |
Outdoor Unit: | |
MOP (A) | 15 |
MCA (A) | 12.3 |
Cooling Rated Amps (A) | 9.95 |
Heating Rated Amps (A) | 9.95 |
Compressor(A) | 9.0 |
Fan Motor (IDU + ODU) (A) | 0.7 + 0.25 |
Cooling Power Input (kW) | 0.4 ~ 0.81 ~ 1.35 |
Heating Power Input (kW) | 0.55 ~ 1.25 ~ 1.58 |
Piping Specifications
Parameter | Value |
---|---|
Liquid Line (in., O.D.) | 1/4 |
Vapor Line (in., O.D.) | 3/8 |
Additional Refrigerant (oz./ft.) | 0.22 |
Max. Pipe Length² (ft.) | 66 |
Piping Length (no add'l refrig., ft.) | 24.6 |
Max. Elevation (ft.) | 49 |
Key Features
- ✅ Hot start
- ? Auto restart
- ⚙️ Inverter (variable speed fan)
- ? Control lock
- ⏰ Timer (on/off)
- ? Sleep Mode
- ? Group control
- ? Optional Wi-Fi Control
System Data
Parameter | Value |
---|---|
Refrigerant Type | R410A |
Refrigerant Control | EEV |
Refrigerant Charge (lbs.) | 2.425 |
ODU Sound Pressure Max (Cool / Heat) ±3 dB(A)³ | 49/52 |
IDU Sound Pressure (H/M/L) ±3 dB(A)³ | 39/32/27 |
ODU Net / Shipping Weight (lbs.) | 74.5/80 |
IDU Net / Shipping Weight (lbs.) | 35.9/42.5 |
Heat Exchanger Coating | GoldFin™ |
Fan Specifications
Parameter | Value |
---|---|
ODU Type | Propeller |
IDU Type | Sirocco |
Fan Speeds (Fan/Cool/Heat) | 4/5/5 |
Fan Quantity (ODU + IDU) | 1 + 1 |
Motor/Drive | Brushless Digitally Controlled/Direct |
ODU Air Circulation (CFM) | 988 |
Air Flow (Max/H/M/L) (CFM) | 353/318/244/184 |
Dehumidification Rate (pts/hr) | 2.5 |
Included Accessories
- Wireless Remote Controller - AKB75735410
Optional Accessories
- MultiSITE™ CRC1 - PREMTBVCO
- MultiSITE CRC1+ - PREMTBVC1
- MultiSITE Comm. Mgr. - PBACNBTR0A
- AC Smart 5 - PACS5A000
- Simple Controller - PREMTC00U
- Wi-Fi module with cable - PWFMDD200
- Low Ambient Wind Baffle (Cooling operation to -4°F) - ZLABGP01A
- Drain Pan Heater - PQSH1202
- Dry Contact for Thermostat - PDRYCB320
- Simple Dry Contact (1 Contact, 24VAC external power) - PDRYCB100
- Dry Contact for Economizer - PDRYCB400
- Premium Remote Controller - PREMTA000
- PI-485 - PMNFP14A1
Notes
1. Acceptable operating voltage: 187V-253V.
2. Piping lengths are equivalent.
3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. All communication/connection (power) cable from the outdoor unit to the indoor unit is field supplied and is to be minimum four-conductor, 14 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
5. See Engineering Manual for sensible and latent capacities.
6. Power wiring cable size must comply with the applicable local and national code.
7. The indoor unit comes with a dry helium charge.
8. This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units.
9. Must follow installation instructions in the applicable LG installation manual.
Dimensional Information
Indoor Unit (IDU - LQN120HV4)
The indoor unit is a low-wall console type. Various views (side, front, top, 3D) are provided showing dimensions and connection points. Key dimensions include:
- Overall Width: Approximately 30-5/16 inches to 31-32 inches.
- Overall Height: Approximately 22-3/16 inches to 23-5/8 inches.
- Overall Depth: Approximately 9-29/32 inches to 10-1/4 inches.
- Key features shown in diagrams include air outlet, control/service valve cover, vapor and liquid pipe connections, conduit, handles, and intake air temperature sensor cover.
- Drain connection holes are indicated (e.g., 4-LD. Φ25/32 Holes).
- Anchor bolt holes are shown (e.g., 4 Holes for Anchor Bolts (M 13/32)).
Outdoor Unit (ODU - LUU127HV)
The outdoor unit is a compact, rectangular unit with a fan grille on top. Views provided include front, side, and top. Key dimensions include:
- Overall Width: Approximately 35-9/32 inches.
- Overall Height: Approximately 25-5/32 inches.
- Overall Depth: Approximately 13-29/32 inches.
- The top view clearly shows the fan opening.
- Side views show access panels and connections.
For a complete list of available accessories, contact your LG representative.
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. | www.lghvac.com
Document Reference: SB_SZ_Console_LQ120HV4_2022_12_13_100734