LG KSUAB121A Submittal

LG KSUAB121A Ductless Mini Split Heat Pump System - Single-Zone - 12k BTU - 22.5 SEER2 - R-32


File Info : application/pdf, 3 Pages, 3.86MB

PDF preview unavailable. Download the PDF instead.

cb4f85fa822281045e3635f58ce4a90a
Job Name/Location: Date: PO No.: Architect: Engr: Rep:
(Company)

For: File

Resubmit

Approval Other

GC: Mech:

(Project Manager)

Tag No.:

KSUAB121A
R32 Single Zone High Efficiency Wall M ount ed

Out door Unit (ODU) - KUSAB121A, Indoor Unit (IDU) - KNUAB121A

Performance:

Cooling:

Cooling Capacity (Min~Rated~Max, Btu/h) SEER2 EER2

1,023 ~ 12,000 ~ 14,100 22.5
12.80

SEER - Seasonal Energy Efficiency Ratio
Heating:

EER - Energy Efficiency Ratio

Heating Capacity (Min~Rated~Max, Btu/h) HSPF2 Max. Heating @ Indoor 70°F DB (Btu/h) Outdoor 17°F WB Outdoor 5°F WB Outdoor -4°F WB

1,023 ~ 13,600 ~ 19,040 10.5
12,400 (91%) 10,000 (74%) 8,010 (59%)

HSPF - Heating Seasonal Performance Factor Cooling Nominal Test Conditions: Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB / 75°F WB
Electrical:

Heating Nominal Test Conditions: Indoor: 70°F DB / 60°F WB Outdoor: 47°F DB / 43°F WB

Power Supply (V¹/Hz/Ø) MOP (A)
MCA (A)

208-230 / 60 / 1
15 12

Cooling / Heating Rated Amps (A)

8.7

Compressor (A)

8.3

Fan Motor (IDU + ODU) (A)

0.4 + 0.4

Cooling Power Input (Min~Rated~Max, kW)

0.20 ~ 0.93 ~ 1.60

Heating Power Input (Min~Rated~Max, kW)

0.19 ~ 1.04 ~ 1.97

Locked Rotor Amps (A)

9.0

MOP - Maximum Overcurrent Protection
Piping:

MCA - Minimum Circuit Ampacity

Installed Liquid Pipe (in., O.D.) Installed Vapor Pipe (in., O.D.) IDU Liquid Connection (in., O.D.) IDU Vapor Connection (in., O.D.) Additional Refrigerant (oz./ft.) Min. / Max. Pipe Length (ft.)² Piping Length (no add'l refrig., ft.) Max. Elevation (ft.)

1/ 4 Flare
3/ 8 Flare 1/ 4 Flare
3/ 8 Flare 0.16
9.8 / 82 41
49.2

Features:
· Inverter (Variable Speed Compressor)
· 24-Hour on/off timer · 4-Way auto swing · Sleep Mode · Jet Cool/Jet Heat · Auto Restart
· Auto Changeover

· Built-in Drain pan heater
· Built-in Wi-Fi via ThinQ app
· Smart Diagnosis · 3M Micro Filter · IDU compatible with
Multi F ODUs

· Low ambient cooling down to 14°F (0°F with Wind Baffle Kit)
· Self-cleaning indoor coil
· IDU R32 leak detection sensor

Included Accessories:
· Wireless Remote Controller -- AKB76044208

Operating Range: Outdoor Unit:

Cooling (°F DB) Heating (°F WB) Indoor Unit:

14 ~ 118 -4 ~ +65

Cooling (°F WB) Heating (°F DB)
System Data:
Refrigerant Type Refrigerant Control
Refrigerant Charge (lbs.) ODU Sound Pressure (Cooling / Heating) (±1 dB[A])3 IDU Sound Pressure Cooling (H/M/L/SL) (±1 dB[A])3
Heating (H/M/L) (±1 dB[A])³ ODU Net / Shipping Weight (lbs.) IDU Net / Shipping Weight (lbs.) Heat Exchanger Coating
Fan:

53 ~ 75 60 ~ 86
R32 EEV
1.81
47 / 51
41 / 35 / 25 / 21 41 / 35 / 26 68.8 / 75.6 19.73 / 22.7
GoldFinTM

ODU Type IDU Type Fan Speeds (Fan/Cool/Heat) Quantity (ODU + IDU) Motor/Drive

Propeller Cross Flow
6 / 6 / 6 1 + 1
Brushless Digitally Controlled / Direct

Maximum ODU Air Volume (CFM)

1,165

IDU Air Flow

Cooling, Max/H/M/L (CFM)

459 / 388 / 318 / 194

Heating, Max/H/M/L (CFM)

459 / 388 / 318 / 229

Dehumidification (pts./hr.)

2.75

Notes:
1. Acceptable operating voltage: 187V-253V. 2. Piping lengths are equivalent. 3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745. 4. All power supply wiring to the outdoor unit is field supplied, solid or stranded. The power wiring and the communication wiring from the outdoor unit to the indoor unit is field supplied and must be stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only). All wiring must comply with applicable local and national codes.
a. Power Supply Wiring to ODU: (No. x AWG): 3 x 14 for 9/12k, 3 x 12 for 18k units. b. Power Wiring / Communication Wiring from Outdoor Unit to Indoor Unit: (No. x AWG) 3 x 14 / 2 x 18. 5. See Engineering Manual for sensible and latent capacities. 6. Power wiring cable size must comply with the applicable local and national code. 7. The indoor unit comes with a dry helium charge. 8. This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units. 9. Must follow installation instructions in the applicable LG installation manual. 10. Multi-compatible 18k IDUs include socket adapters for refrigerant pipe connections with single zone systems.
BACnet® is a registered trademark of ASHRAE. LonWorks® is a trademark of Echelon Corporation.

Optional Accessories:

 PI-485 - PMNFP14A1  Single-Port Shutoff Valve - PRHPZ010A  Low Ambient Wind Baffle (Cooling to 0°F) - ZLABGP01A

Controller Options:

 MultiSITETM CRC* Controllers  Simple Remote Controllers  Standard III Remote Controllers  Remote Temp. Button Sensor  Dry Contacts

 AC Smart 5 Central Controller  LonWorks® Gateway  MultiSITE Comm. Mgr.  AC Smart BACnet® Gateway

Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps (excluding ductless systems) must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar. gov. (ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency.)

For a complete list of available accessories, contact your LG representative. For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com

SB_SZ_Hi gh _Ef f i ci en cy_R32_KSUAB121A_2024_12_18_163712
Page 1 of 3

Job Name/Location:
KSUAB121A
R32 Single Zone High Efficiency Wall M ount ed
Out door Unit (ODU) - KUSAB121A, Indoor Unit (IDU) - KNUAB121A

Tag No.: Date: PO No.:

For continual product development, LG reserves the right to change specifications without notice.

SB_SZ_Hi gh _Ef f i ci en cy_R32_KSUAB121A_2024_12_18_163712

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com

Page 2 of 3

Job Name/Location:
KSUAB121A
R32 Single Zone High Efficiency Wall M ount ed
Out door Unit (ODU) - KUSAB121A, Indoor Unit (IDU) - KNUAB121A

Tag No.: Date: PO No.:

For continual product development, LG reserves the right to change specifications without notice.

SB_SZ_Hi gh _Ef f i ci en cy_R32_KSUAB121A_2024_12_18_163712

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com

Page 3 of 3

