Instruction Manual for LG models including: KSSAC241A, KUSAC241A, KNSAC241A, KSSAC241A Single Zone Mega Wall Mount, KSSAC241A, Single Zone Mega Wall Mount, Zone Mega Wall Mount, Mega Wall Mount, Mount

KSSAC241A


File Info : application/pdf, 3 Pages, 4.50MB

PDF preview unavailable. Download the PDF instead.

f865b49c297b816be6f01a500c748174 ?srsltid=AfmBOopZm0E8ImKS20RjeAZIh1ErtUmMSmGfHRz62RdU7c8e-CYNTlXZ
Job Name/Location: Date: PO No.: Architect: Engr: Rep:
(Company)

For: File

Resubmit

Approval Other

GC: Mech:

(Project Manager)

Tag No.:

KSSAC241A
R32 Single Zone M ega Wall M ount

Out door Unit (ODU) - KUSAC241A, Indoor Unit (IDU) -KNSAC241A

Performance: Cooling:

Cooling Capacity (Min~Rated~Max) (Btu/h) SEER2 EER2
SEER - Seasonal Energy Efficiency Ratio
Heating: Heating Capacity (Min~Rated~Max) (Btu/h) HSPF2 Max. Heating @ Indoor 70°F DB Outdoor 19°F DB / 17°F WB Outdoor 6°F DB / 5°F WB
HSPF - Heating Seasonal Performance Factor Cooling Nominal Test Conditions: Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB / 75°F WB

3,685 ~ 21,200 ~ 24,500

EER - Energy Efficiency Ratio

20.0 12.3

3,685 ~ 22,000 ~ 25,260 17,700

Heating Nominal Test Conditions: Indoor: 70°F DB / 60°F WB Outdoor: 47°F DB / 43°F WB

8.8 13,800

Electrical:
Power Supply (V¹/Hz/Ø) MOP (A) MCA (A) Cooling Rated Amps (A) Heating Rated Amps (A) Compressor (A) Fan Motor (IDU + ODU) (A) Cooling Power Input (kW) (Min~Rated~Max @95°F) (kW) Heating Power Input (kW) (Min~Rated~Max @47°F) (kW)

208-230/60/1
20 15 10.1 10.6 10.0 0.4 + 0.6
0.24 ~ 1.723 ~ 2.7
0.24 ~ 1.894 ~ 2.5

MOP - Maximum Overcurrent Protection
Piping:

MCA - Minimum Circuit Ampacity

Liquid Line (in., O.D.)
Vapor Line (in., O.D.)
Additional Refrigerant (oz./ft.) Min. / Max. Pipe Length (ft.)² Piping Length (no add'l refrig., ft.) Max. Elevation (ft.)

1/ 4 1/ 2 0.22 9.8 / 65.6 24.6 32.8

Features:

· 24-Hour on/off timer

· Built-in Wi-Fi via ThinQTM app

· Two-way (up / down) auto swing · Inverter (variable speed

· Auto changeover

compressor)

· Auto restart

· Self-cleaning indoor coil

· Jet cool/Jet heat

· Sleep mode

· Smart Care

· Ultra-quiet operation

· Smart Diagnosis

Operating Range: Outdoor Unit:
Cooling (°F DB) Heating (°F WB)

14 ~ 118 5 ~ 65

Indoor Unit:
Cooling (°F WB) Heating (°F DB)
System Data:
Refrigerant Type Refrigerant Control Refrigerant Charge (lbs.) ODU Sound Pressure (Cooling / Heating) (±1 dB[A])³ IDU Sound Pressure Cooling (H/M/L/Sleep) (±1 dB[A])³ Heating (H/M/L) (±1 dB[A])³ ODU Net / Shipping Weight (lbs.) IDU Net / Shipping Weight (lbs.) Heat Exchanger Coating

53 ~ 75 60 ~ 86
R32 EEV
2.43
55 / 55
48 / 43 / 38 / 32 48 / 43 / 38 92.6 / 102.5 26 / 30
GoldFinTM

Fan:
ODU Type IDU Type Fan Speeds (Fan/Cool/Heat) Quantity (ODU + IDU) Motor/Drive ODU Max. Air Flow Rate (CFM) IDU Air Flow Cooling, Max/H/M/L (CFM) Heating, Max/H/M/L (CFM) Dehumidification (pts./hr.)

Propeller Cross Flow
6 / 6 / 6 1 + 1
Brushless Digitally Controlled/Direct
1,730
689 / 512 / 459 / 371 653 / 565 / 477 / 388
3.38

Notes:
1. Acceptable operating voltage: 187V-253V. 2. Piping lengths are equivalent.
3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and must be a minimum of four-conductor, 14 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes. 5. See Engineering Manual for sensible and latent capacities. 6. Power wiring cable size must comply with the applicable local and national code. 7. The indoor unit comes with a dry helium charge.
8. This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units.
9. Must follow installation instructions in the applicable LG installation manual.

Included Accessories: · Wireless Remote Controller -- AKB76044207

Controller Options:  MultiSITETM CRC* Controllers  Simple Remote Controllers  Standard III Remote Controllers  Deluxe Remote Controller  Dry Contacts

Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps (excluding ductless systems) must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar.gov. (ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency.)

For a complete list of available accessories, contact your LG representative. For continual product development, LG reserves the right to change specifications without notice.

SB_SZ_M ega_WallM ount ed_R32_KSSAC241A_2025_01_06_115229

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com

Page 1 of 3

Job Name/Location:
KSSAC241A
R32 Single Zone M ega Wall M ount Out door Unit (ODU) - KUSAC241A, Indoor Unit (IDU) -KNSAC241A

Tag No.: Date: PO No.:

For continual product development, LG reserves the right to change specifications without notice.

SB_SZ_M ega_WallM ount ed_R32_KSSAC241A_2025_01_06_115229

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com

Page 2 of 3

Job Name/Location:
KSSAC241A
R32 Single Zone M ega Wall M ount Out door Unit (ODU) - KUSAC241A, Indoor Unit (IDU) -KNSAC241A

Tag No.: Date: PO No.:

SB_SZ_M ega_WallM ount ed_R32_KSSAC241A_2025_01_06_115229

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com

Page 3 of 3



References

Adobe PDF Library 17.0; modified using iTextSharp 4.1.6 by 1T3XT Adobe InDesign 19.5 (Windows)