FXLuminaire Designer/Standard Down Light

Model Series: VE, LE, VL, LS

Installation Instructions

Follow these steps for installation:

  1. Step 1: Change color filter and beam angle lens by removing and replacing existing components if desired (Designer Series only). Use a 5/64" Allen key.
  2. Step 2: Thread the cable through the fixture loop and around the desired mounting surface. Insert both cable ends into the lock mechanism.
  3. Step 3: Run the wire down the structure and secure with cable ties.
  4. Step 4: Use a voltmeter to ensure 11 to 15V at the fixture.
  5. Step 5: Connect wiring with a waterproof connector.

(Note: Installation instructions are available in multiple languages including English, Spanish, French, German, and Russian.)

Circuiting Guidelines

Transformer Usage

Single Transformer: When using one transformer, center it on the wattage load. Minimize all cable runs to reduce voltage drop.

Multiple Transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the fixtures as possible.

Low Voltage Wiring (15V)

Wire Gauge (AWG/mm²)Max Wattage (W)Max Cable Run (ft/m)
12 AWG (4.0 mm²)< 160 W0-40' (0-13 m)
10 AWG (6.0 mm²)< 180 W0-40' (0-13 m)
12 AWG (4.0 mm²)< 120 W40-80' (13-25 m)
10 AWG (6.0 mm²)< 140 W40-80' (13-25 m)
12 AWG (4.0 mm²)< 100 W80-120' (25-40 m)
10 AWG (6.0 mm²)< 120 W80-120' (25-40 m)
12 AWG (4.0 mm²)< 60 W120-160' (37-50 m)
10 AWG (6.0 mm²)< 100 W120-160' (37-50 m)

Safety and Use Instructions

Please read and keep all safety and use instructions. For questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.

⚠️ WARNING: To reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.
  • Lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch hot lens, guard, or enclosure.
  • Keep lamp away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield.

⚡ WARNING: Risk of Electric Shock

  • May be installed less than 5' (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer (✅UL379).
  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

Low Voltage Cable Requirements:

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6" (152 mm) in order to connect to the main low voltage cable.
  • Have the length cut off so that it is connected to a connector within 6" (152 mm) from a building structure, a luminaire, or fitting.

Product Information

These products contain a light source of energy efficiency class G.

Certifications:

  • CE Certified Down Lights: VE, LE (✅CE)
  • Non-CE Certified Down Lights: VL, LS
  • UL LISTED (3YJ8) (✅UL)
Models: LE-1LED-BZ Designer Premium Down Light, LE-1LED-BZ, Designer Premium Down Light, Premium Down Light, Down Light, Light

File Info : application/pdf, 2 Pages, 692.81KB

PDF preview unavailable. Download the PDF instead.

185310 2022330151844

References

PDFium PDFium

Related Documents

Preview FXLuminaire Designer/Standard Wall Light Installation and Safety Guide
Installation and safety guide for FXLuminaire Designer/Standard Wall Lights (PO, MO, VO, CG). Covers circuiting, transformer usage, and essential safety precautions for low-voltage landscape lighting.
Preview FXLuminaire Wall Light Installation and Safety Guide (CP, LM, UN, PD)
A comprehensive guide for FXLuminaire CP, LM, UN, and PD wall lights, detailing installation steps, crucial safety warnings, technical specifications, and compliance information.
Preview FXLuminaire BQ Landscape Lighting Installation and Safety Guide
Comprehensive installation instructions, circuiting guidelines, and safety warnings for the FXLuminaire BQ designer specialty light.
Preview FXLuminaire Designer/Standard Wall Light Installation Guide (PO, MO, VO, CG)
Comprehensive installation, circuiting, and safety guide for FXLuminaire Designer/Standard wall lights, including PO, MO, VO, and CG models. Provides step-by-step instructions, wiring guidelines, and essential safety precautions.
Preview FXLuminaire VK LED Wall Light: Specifications, Features, and Ordering Guide
Detailed specifications, features, materials, and ordering information for the FXLuminaire VK LED Wall Light, a modern, sleek, and durable recessed luminaire designed for landscape and architectural applications. Includes technical data, photometrics, and finish options.
Preview FXLuminaire ST-UV Transformer: 30W Universal Voltage Step-Down Transformer
Discover the FXLuminaire ST-UV Transformer, a 30W universal voltage step-down transformer for landscape and architectural lighting. Key features include 85-305 VAC input, 12 VAC output, compact design, and screw terminal mounting.
Preview Building Your Landscape Lighting Business: A Comprehensive Guide
A comprehensive guide for landscape lighting contractors, covering design techniques, fixture specification, lighting control systems, and business strategies from FX Luminaire.
Preview FXLuminaire XN-70 In-Grade Light Installation and Safety
Essential safety and installation instructions for the FXLuminaire XN-70 In-Grade Light, designed for landscape and architectural lighting. Covers handling, electrical safety, and low-voltage cable guidelines.