Portable Air Conditioner Owner's Manual
Item No: A4211-8K
Applicable Model: OL-BA011D1-05CD/D2
(With R32 refrigerant)
READ AND SAVE THESE INSTRUCTIONS
1. BEFORE YOU BEGIN
1.1 PRODUCT DESCRIPTION
Our powerful portable air conditioners are great cooling solutions for single rooms, creating a comfortable atmosphere in your space. It also has ventilation and dehumidifying function for circulating air and removal of moisture. They're self-contained systems that do not require any permanent installation allowing you to move to the space in which it is most needed. They're commonly used in kitchens, temporary-resided, computer rooms, garages, and many other places where installation of an Air-conditioner Outdoor Unit is limited.
The environmentally friendly R32 is used as the refrigerant. R32 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide. Because of its efficient energy properties, R32 is highly suitable as a coolant for this application. Special precautions must be taken into consideration due to the coolant's high flammability.
1.2 SYMBOLS FROM THE UNIT AND USER MANUAL
- ⚠️ WARNING: This unit uses a flammable refrigerant. If refrigerant leaks and comes in contact with a fire or heating part, it will create harmful gas and there is a risk of fire.
- ? Read the USER MANUAL carefully before operation.
- ℹ️ Further information is available in the USER MANUAL, SERVICE MANUAL, and the like.
- ? Service personnel is required to carefully read the USER MANUAL and SERVICE MANUAL before operation.
2. FOR YOUR SAFETY
Your safety is the most important thing we are concerned about!
⚠️ WARNING: Please read this manual carefully and fully understand before operating your appliance.
2.1 OPERATIONAL PRECAUTIONS
WARNING- to reduce the risk of fire, electric shock or injury to persons or property:
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The appliance shall be disconnected from its power source during service.
- Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
- Always use a power outlet that is grounded.
- Unplug the power cord when cleaning or when not in use.
- Do not operate with wet hands. Prevent water from spilling onto the unit.
- Do not immerse or expose the unit to rain, moisture or any other liquid.
- Do not leave the unit running unattended. Do not tilt or turn over the unit.
- Do not unplug while the unit is operating.
- Do not unplug by pulling on the power cord.
- Do not use an extension cord or an adapter plug.
- Do not put objects on the unit.
- Do not climb or sit on the unit.
- Do not insert fingers or other objects into the air outlet.
- Do not touch the air inlet or the aluminum fins of the unit.
- Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
- Do not clean the appliance with any chemicals.
- Ensure the unit is far away from fire, inflammable, or explosive objects.
- The unit shall be installed in accordance with national wiring regulations.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuous operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- Do not piece or burn, even after use.
- Be aware that refrigerants may not contain an odour.
- Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than 4m².
- Compliance with national gas regulations shall be observed.
- Keep any required ventilation openings clear of obstruction.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
⚠️ WARNING: Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry, recognized assessment specification.
⚠️ WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
If you don't understand something or need help, please contact the dealer services.
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when undertaking the following when servicing an appliance with R32.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
2.2.2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of flammable gas or vapor being present while the work is being performed.
2.2.3 General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
2.2.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.
2.2.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
2.2.6 No ignition sources
No person carrying out work in relation to a refrigeration system that involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removal and disposal, during which flammable refrigerant can possibly be released into the surrounding space. Prior to work takes place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking" signs shall be displayed.
2.2.7 Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
2.2.8 Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall be followed. If in doubt consult the manufacturer's technical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
- The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
- The ventilation machinery and outlets are operating adequately and are not obstructed;
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
- Marking of the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
- Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
2.2.9 Checks to electrical devices
Repair and maintenance of electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
- Capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
- No live electrical components and wiring are exposed while charging, recovering or purging the system;
- Continuity of earth bonding.
⚠️ WARNING! Install the unit in rooms that exceed 4 m².
Do not install the unit in a place where inflammable gas may leak.
ℹ️ NOTE! The manufacturer may provide other suitable examples or may provide additional information about the refrigerant odor.
3. PRODUCT OVERVIEW
3.1 PRODUCT DIAGRAM
Diagram Description: An illustration of the portable air conditioner showing its front and back views with numbered components.
- 1. Control panel: The interface for operating the unit.
- 2. Air outlet with adjustable louver: Where the conditioned air is expelled.
- 3. Handle: For moving the unit.
- 4. Air inlet with air filter: Where air is drawn into the unit for cooling.
- 5. Caster: Wheels for easy mobility.
- 6. Drainage Hole: Outlet for condensate water.
- 7. Air Exhaust: Outlet for hot air and moisture.
Note: The appearance is only for reference. Please check the real product for detailed information.
3.2 FEATURES
- High Capacity in a compact size with cooling, dehumidifying and fan functions.
- Temperature setting and display
- LED Digital display
- Electronic control with a built-in timer, sleep mode
- Self-evaporating system for better efficiency
- Auto shut off when tank-full
- Automatic restart in the event of a power outage
- Auto defrosting function at low ambient temperatures
- Remote control
- 2-speed fan
- Casters for easy mobility
4. INSTALLATION
4.1 UNPACKING
- Unpack the carton and take the appliance and accessories out.
- Check the device after unpacking for any damage or scratches on it.
Accessories:
- 1. Exhaust hose
- 2. Hose connector
- 3. Window kit adapter
- 4. Remote control
- 5. Window kit
- 6. Water pipe
- 7. User manual
Diagram Description: Illustrations of the accessories: an exhaust hose, a hose connector, a window kit adapter, a remote control, a window kit, and a water pipe.
4.2 Choose your location
- If tipped more than 45°, allow the unit to set upright for at least 24 hours before starting up.
- Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation.
- Do not operate in close proximity to walls, curtains, or other objects that may block the air inlet and outlet. Keep the air inlet and outlet free of obstacles.
- Never install the unit where it could be subject to:
- Heat sources such as radiators, heat registers, stoves or other products that produce heat.
- Direct sunlight
- Mechanical vibration or shock
- Excessive dust
- Lack of ventilation, such as cabinet or bookcase
- Uneven surface
⚠️ WARNING! Install the unit in rooms that exceed 4 m².
Do not install the unit in a place where inflammable gas may leak.
ℹ️ NOTE! The manufacturer may provide other suitable examples or may provide additional information about the refrigerant odour.
Diagram Description: An illustration showing the recommended placement of the unit with 50cm clearance around it, and a truck indicating the unit should be kept upright.
4.3 ATTACH THE EXHAUST HOSE
The air conditioner requires being vented outside so that the exhaust air can escape the room. The exhaust air contains waste heat and moisture.
Do not replace or extend the exhaust hose, which will result in decreased efficiency, even worse shut down the unit due to low back pressure.
- Step 1: Connect the hose connector to one end of the exhaust hose.
- Step 2: Connect the window kit adapter to the other end of the exhaust hose.
- Step 3: Extend the adjustable window kit to the length of your window. Connect the exhaust hose to the window kit.
Diagram Description: Illustrations showing the connection of the hose connector to the exhaust hose, and the window kit adapter to the other end of the hose. Another illustration shows the window kit being extended and connected to the hose.
- Step 4: Close your window to secure the kit in place. It needs to hold the windows kit firmly in place, and secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.
Diagram Description: An illustration showing the window kit installed in a window, with the exhaust hose connected, and an arrow indicating sealing the gap.
- Step 5: Attach the hose connector to the exhaust air outlet of the unit.
- Step 6: Adjusting the length of the flexible exhaust hose, to make sure the distance between the unit and the window will be more than 70cm, the height from exhaust hose to the floor will be more than 90cm. Avoid bends in the hose. Then place AC near an electrical outlet.
Diagram Description: An illustration showing the exhaust hose attached to the back of the portable air conditioner unit.
- Step 7: Adjust the louver at the air outlet, and then switch on the unit.
Diagram Description: An illustration showing the portable air conditioner unit placed near a window with the exhaust hose connected, and the unit powered on.
5. OPERATION
5.1 CONTROL PANEL AND DISPLAY
Diagram Description: An illustration of the control panel with numbered buttons and indicators.
# | Label | Description |
---|---|---|
1 | POWER | Press to switch the machine on or off. |
2 | MODE | Press to switch the operation mode between fan, cooling and dehumidifier. |
3 | FAN SPEED Indicator | Display high fan speed & low fan speed. |
4 | MODE Indicator | The Mode Display between Cooling, Dehumidifying, fan. |
5 | TIMER Indicator | Display the Timer on. |
6 | DOWN | Decreasing the desired temperature or timer setting. |
7 | Digital Display | Displays timer setting and room temperature. |
8 | UP | Increasing the desired temperature (61°F-90°F) or timer setting. |
9 | SPEED | Press to switch the fan speed between HIGH and LOW. |
10 | TIMER | Sets a time for the unit to automatically start or stop. |
5.2 REMOTE CONTROL
Diagram Description: An illustration of the remote control with various buttons for operation.
5.3 SETTINGS
5.3.1 Start-up and Shutdown
- Press POWER to turn the unit on.
- The unit runs in FAN as default.
- Press MODE button to select the desired operation mode.
- Press POWER again to turn off the power.
5.3.2 Operation mode
The unit has four operation modes: Cool, dry, fan, sleep. The unit working temperature under cooling mode is 61°F-95°F.
A. Cooling your room
- Select the cool mode to lower the temperature in your room.
- Press MODE button repeatedly until the LED of COOL operation lights up.
- Press Up/Down button to adjust the temperature which is displayed on the screen. The temperature can be set between 61°F and 90°F.
- Press SPEED button repeatedly until the desired fan speed indicator lights up.
- To control the direction of the air flow horizontally, please adjust the inner louver by hand.
- Note: The air conditioner stops if the room temperature is lower than selected temperature.
B. Ventilating your room
- Press MODE button repeatedly until the LED of FAN operation lights up.
- In ventilation mode, the room air is circulated, but not cooled.
- Press SPEED button repeatedly to select the fan speed as desired.
C. Drying your room
- Press the MODE button on the control panel or remote control, and the LED of DRY operation lights up. The fan speed is unable to select.
- The user should connect the hose to the drain outlet at the bottom of the unit.
- Note: In this mode, the fan speed switches over to low speed and cannot be selected.
D. Sleep mode (this function can only be used with a remote control)
- The sleep mode can be activated when in cool mode and heat mode.
- In cool mode: After 1 hour the preset temperature is increased by 2°F, after another hour the preset temperature will again be increased by 2°F.
5.3.3 TIMER SETTING (1hour-24hours)
The timer has two ways of operation:
To turn off (When power on): Press Timer key to turn on the timer function. ➡️ Press Up/Down repeatedly to set the delay OFF time.
To turn on (When power off): Press Timer key to turn on the timer function. ➡️ Press Up/Down repeatedly to set the delay ON time.
Cancel timer: Press Up/Down repeatedly until the LED shows '00'.
Note: Pressing POWER will also exit the timer setting.
5.3.4 Automatic Defrost
At low room temperatures, frost may build up at the evaporator during operation. The unit will automatically start defrosting and the POWER LED will blink. The defrost control sequence is as follows:
- A. When the unit operates in the cooling operation, drying operation, the ambient temperature sensor senses the evaporator coil temperature is below 30°F, after the compressor will stop operating for 10 minutes or the coil temperature up to 44°F, the unit restarts to cool operating mode.
- B. When the unit operates in the drying operation, once the coil temperature sensor senses the temperature of the evaporator is below 104°F and the differential temperature between coil temperature and room temperature is below 66°F after the compressor operation for 20 minutes, the unit starts defrosting for 5 minutes and the power indicator blinks.
5.3.5 Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor restarting.
5.4 DRAINAGE
Manual drainage:
- When the machine stops after the water is full, please unplug the power plug. Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom of the body.
- Place the water container below the side water outlet behind the body.
- Unplug the water plug; the water will automatically flow into the water container.
Notes:
- Keep the water plug properly.
- During drainage, the body can be tilted slightly backward.
- If the water container cannot hold all the water, before the water container is full, stuff the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet.
- When the water is discharged, stuff the water plug. Notes: 1. Restart the machine after the water plug and drainage cover are installed, otherwise condensate water of the machine will flow to the floor or the carpet.
Diagram Description: An illustration of the rear of the portable air conditioner unit showing the drainage outlet and plug.
Continuous drainage
The self-evaporating system uses the collected water to cool the condenser coils for better efficient performance. It is no need to empty the drainage tank in cooling operation except in drying operation and high humidity conditions. The condensate water evaporates at the condenser and is evacuated through the exhaust hose.
For continuous operation or unattended operation in drying operation, please connect the attached drain hose to the unit. Condensate water can be automatically flow into a bucket or drain by gravity.
- Switch off the unit before operating.
- Remove the plug of the water outlet opening, and keep it in a safe area.
- Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction.
- Place the outlet of the hose over a drain or bucket and ensure that water could freely flow out of the unit.
- Do not submerge the end of the hose into water; otherwise it can cause an "Air Lock" in the hose.
To avoid water spillage:
- As the negative pressure of the condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
- Straighten the hose to avoid a trap existing in the hose.
Diagram Description: An illustration showing the continuous drainage setup with a hose connected to the unit and draining into a bucket.
6. CLEANING AND CARE
6.1. CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.
- Press POWER button to switch off the unit and unplug the power cord.
- Remove the filter mesh from the unit.
- Use a vacuum cleaner to suck dust from the filter.
- Turn the filter over and rinse the air filter under running water. Let the water run through the filter in the opposite direction of air flow. Set aside and allow the filter to air dry completely before reinstalling.
Switch off the unit and remove the air filters. Rinse the air filter under the running water.
⚠️ Warning!!! Do not touch the evaporator surface with bare hand, or could cause injury to your fingers.
Diagram Description: An illustration showing an air filter being rinsed under a faucet with water flowing through it.
6.2. CLEANING UP OF REFRIGERANT
General Measures:
- Gas/vapor is heavier than air, which may accumulate in confined spaces, particularly at or below ground level.
- Eliminate every possible source of ignition.
- Use appropriate personal protection equipment (PPE).
- Evacuate unnecessary personnel, isolate, and ventilate the area.
- Do not let it into the eyes, on the skin, or clothing. Do not inhale vapors or gas.
- Prevent it entering to sewers and public water areas.
- Block the source of the release, if safe to do so. Consider the use of water spray to disperse vapors.
- Isolate the area until the gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill.
7. TROUBLESHOOTING
Symptom | Inspection | Solution |
---|---|---|
The unit is not operating. | Check the power connection securely. Check if the water level indicator lights up? Check the room temperature. |
Insert the power cord securely into the wall outlet. Empty the drain pan by removing the rubber plug. The range of operating temperature is 41-95°F. |
The unit works with reduced capacity. | Check the air filter for dirt. Check if the air duct is blocked. Check if the room door or window is open. |
Clean the air filter as necessary. To clear the obstacle. Keep the door and windows closed. |
Water Leakage | Check if the desired operating mode is selected and the temperature is properly set. The exhaust hose is detached. Overflow while moving the unit. Check if the drain hose is kinked or bends. |
Set the mode and temperature at proper set-point according to the manual. Make sure the exhaust hose is securely attached. Empty the water tank before transport. Straighten the hose to avoid a trap existing. |
Excessive Noise | Check if the unit is securely positioned. Check if any loose, vibrating parts. The noise sounds like water flowing. |
Place the unit on horizontal and firm ground. Secure and tight the parts. Noise comes from flowing refrigerant. This is normal. |
Error Codes | E0: Communication faults between the main PCB and display PCB. E1: Ambient temperature sensor failure E2: Coil temperature sensor failures. Ft: Condensate water high level alarm. |
Check the wire harness of the display PCB for damage. Check the connection or replace it. To clean or replace the temperature sensor. Check the connection or replace it. To clean or replace the temperature sensor. Empty the drain pan by removal the rubber plug. |
8. DECOMMISSIONING
8.1. STORAGE
Long-Term Storage: If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit per the following steps:
- Unplug the unit and remove the exhaust hose and window kit stored with the unit.
- Drain the remaining water from the unit.
- Clean the filter and let the filter dry completely in a shaded area.
- Re-install the filter at its position.
- The unit must be kept in upright position when in storage.
- Preserve the machine in a ventilating, dry, non-corrosive gas and safe place indoor.
ATTENTION: The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is to turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.
8.2. DISPOSAL
⚠️ WARNING!!! Releasing refrigerant into the atmosphere is strictly forbidden!
Do not dispose of electrical appliances as unsorted municipal waste; use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
Diagram Description: An icon indicating that electrical appliances should not be disposed of in regular trash, often depicted as a crossed-out waste bin.
Contact Information
Thank you for purchasing this product! If you have any questions about the product, such as missing parts, damaged products, product assembling, and operation, please contact us via Amazon Message or customer service number: 213-4467172 or 661-4358826.
IMPORTANT
Please call our customer service department for any consulting:
213-4467172
661-4358826
(8:30am - 5:30pm P.S.T.)
DATED PROOF OF PURCHASE IS REQUIRED FOR WARRANTY SERVICE.
AVIS
Veuillez appeler le service à la clientèle pour toutes questions au:
213-4467172
661-4358826
(8:30am - 5:30pm P.S.T.)
PREUVE D'ACHAT ORIGINALE REQUISE POUR SERVICE DE GARANTIE.
IMPORTANTE
Sólo hay que llamar nuestro departamento de servicio al cliente en caso de tener preguntas o inquietudes:
213-4467172
661-4358826
(8:30am - 5:30pm P.S.T.)
SE REQUIERE PRUEBA DE COMPRA CON FECHA PARA SERVICIO BAJO GARANTÍA.
Address: ROWAN ELECTRIC APPLIANCE LLC
28407 Ascent Way, Santa Clarita, CA 91350
Phone: 213-4467172 or 661-4358826