nVent RAYCHEM ETL Self-Regulating Heat Cables for Pipe Freeze Protection
nVent RAYCHEM ETL self-regulating heat cables keep pipes from freezing in buildings, both indoors and outdoors.
Product Features
- Can be cut to the correct length on-site.
- Compact size facilitates installation.
- CR-sheathed heat cable can be installed on the outside of the pipe, and CT-sheathed cable on both the outside and inside.
- Models with 10 W/m and 16 W/m power output for various pipe diameters.
- Completely maintenance-free after installation and commissioning.
- No risk of overheating thanks to self-regulating technology.
Self-Regulating Technology
ETL cables are based on self-regulating technology. The power output automatically adjusts at different points along the cable according to the ambient temperature. The cable will never overheat, even if installed in a crossed configuration.
Self-Regulating ETL Heat Cables
Product | Nominal Power @ 5°C | Voltage | Temperature Resistance (cable powered off, max 800h) | Dimensions | Grounding | Electrical Insulation | Outer Jacket | Min. Installation Temp. | Min. Bend Radius | Max. Heating Circuit Length (at 5°C) | Certifications & Approvals | Product Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|
R-ETL-A | 10 W/m (16 W/m at 5°C inside pipe in water) | 230 Vac | 65°C | 8.5 mm x 5.8 mm | Tinned copper braid | Irradiated cross-linked modified polyolefin | Drinking water approved | -20°C | 10 mm | 100 m (10 A) on pipe side 60 m (10 A) inside pipe | Tested and approved according to IEC62395 standard. CE marking. | 924269-000 |
R-ETL-B | 16 W/m (25 W/m at 5°C inside pipe in water) | 230 Vac | 65°C | 8.5 mm x 5.8 mm | Tinned copper braid | Irradiated cross-linked modified polyolefin | Drinking water approved | -20°C | 10 mm | 100 m (16 A) on pipe side 60 m (16 A) inside pipe | Tested and approved according to IEC62395 standard. CE marking. | P000002042 |
R-ETL-A-CR | 10 W/m | 230 Vac | 65°C | 8.5 mm x 5.8 mm | Tinned copper braid | Irradiated cross-linked modified polyolefin | UV protected | -20°C | 10 mm | 100 m (10 A) on pipe side | Tested and approved according to IEC62395 standard. CE marking. | P000002043 |
R-ETL-B-CR | 16 W/m | 230 Vac | 65°C | 8.5 mm x 5.8 mm | Tinned copper braid | Irradiated cross-linked modified polyolefin | UV protected | -20°C | 10 mm | 100 m (16 A) on pipe side | Tested and approved according to IEC62395 standard. CE marking. | P000002044 |
Easy Planning and Installation
Unlike standard resistance heat cables, the planning and cutting of ETL cables to the correct length can be done on-site. The heat cable is terminated with an end-seal kit at the end of the pipe. For efficient operation and complete peace of mind, a wide range of manufacturer-designed, tested, and approved connection and electrical accessories are also available for the heat cables.
nVent RAYCHEM Controls
Part Number | Designation | Description |
---|---|---|
35 301 73 | AT-TS-13 | Pipe temperature sensing freeze protection thermostat. Control range: -5°C - +15°C |
35 301 74 | AT-TS-14 | Pipe temperature sensing freeze protection thermostat. Control range: 0°C - +120°C |
35 301 70 | RayStat-ECO-10 | Ambient thermostat and relative control based on ambient temperature measurement (PASC) |
35 301 71 | RayStat-CONTROL-10 | Pipe temperature sensing thermostat with volt-free alarm relay |
26 154 72 | RayStat-CONTROL-11-DIN | Pipe temperature sensing thermostat with digital display (DIN rail mounting) |
34 184 24-29 | SBS-R-FP Control Panels | Control panel configuration includes main switch and residual current and circuit breakers. |
nVent RAYCHEM Installation Accessories
Part Number | Designation | Description |
---|---|---|
04 309 91 | JLP | Splice and end-seal kit for R-ETL heat cables |
17 490 00 | ETL-Gland-01 | Cable gland R20 |
04 310 42 | JB16-02 | Junction box |
nVent RAYCHEM Additional Accessories
Part Number | Designation | Description |
---|---|---|
04 310 49 | GT-66 | Heat-resistant fiberglass tape (20-meter roll) |
04 310 47 | ATE-180 | Aluminum tape, 55m/roll, for plastic pipes |
64 150 60 | LAB-ETL-SF | Electrical tracing warning label |
nVent RAYCHEM Heat Cable Selection
Pipe freeze protection. Max. maintenance temperature 40°C.
Freeze Protection down to -20°C
Insulation Thickness (mm) | 15 | 22 | 28 | 35 | 42 | 54 | 67 | 76 | 108 | 125 | 150 | 200 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
10 | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
15 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A | N/A | N/A |
20 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A | N/A |
25 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A |
30 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A |
40 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A |
50 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A |
Freeze Protection down to -40°C
Insulation Thickness (mm) | 15 | 22 | 28 | 35 | 42 | 54 | 67 | 76 | 108 | 125 | 150 | 200 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
10 | R-ETL-B (-CR) | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
15 | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
20 | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
25 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
30 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
40 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A | N/A |
50 | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-A (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | R-ETL-B (-CR) | N/A | N/A | N/A | N/A |
Contact Information
Finland
Phone: 0800 11 67 99
Email: salesfi@nvent.com