FG-27 Bluetooth Communication Interface for FG Instruction Manual

FG-27 is a wireless communication option. Attach to the FG series scale.

1. Installation Procedure

Note: Remove the AC adapter from the scale. If you use batteries, remove the battery box.

  1. Remove four screws on the Option slot cover and remove the cover from the display unit.
  2. Insert the interface board into the display unit and connect the connector.
  3. Firmly secure the Option panel to the display unit using the four screws removed at Step 1.

Diagram Description: The diagram shows the FG-27 interface board being inserted into the display unit's option slot. The interface board has a connector that plugs into the unit. The option slot cover is removed and then reattached with screws to secure the panel.

2. Connectable Device

  • Smartphone/Tablet via App: Install A&D WeiV® (App)
  • AD-8931: Wireless Remote Display
  • AD-8541-PC: Wireless Communication Interface for PC (Connect to USB port of computer)

Note 1: Refer to the A&D website for details.

  • Smartphone/Tablet/PC with Bluetooth via HID: Refer to "5. HID Function (HID Over GATT Profile)".
  • Note 2: Turn on DIP switch No.1. Refer to "3. DIP Switch".

3. DIP Switch

Switch the DIP switch settings depending on the connected device. From "2. Connectable Device":

  • For A&D WeiV: Case 1
  • For AD-8931: Case 1
  • For AD-8541-PC: Case 1
  • For Tablet etc.: Case 2

Note: To switch the DIP switch settings, use a rounded object such as the tip of a ballpoint pen to slide it.

Diagram Description: The diagram illustrates the DIP switch, which consists of two switches labeled 'No. 1 SELECT' and 'No. 2 SERIAL'. The switches can be set to 'ON' or 'OFF'. The table below shows the settings for 'Two-way communication (Factory Setting)' with both switches OFF, and 'Keyboard input' with No. 1 ON and No. 2 OFF.

CaseDIP switchOutput Data
No. 1 SELECTNo. 2 SERIAL
1
(Two-way communication
(Factory Setting))
OFFOFFConnect to AD-8931, AD-8541-PC,
or A&D WeiV
2
(Keyboard input)
ONOFFOnly numerical data
(No header, no + sign or no unit)
Example 1) 1.23
Example 2) -4.56
Data

4. Setting the Scale (FG Series)

Refer to the instruction manual of the scale (HV-C/CP, HW-C/CP series) to set the functions.

  • Set function "F4" to "".
  • Set function "FS" to " ". (In case of connection to the AD-8931)

5. HID Function (HID Over GATT Profile)

By turning on DIP switch No.1, you can connect to a Smartphone, tablet, or PC with Bluetooth and use a general-purpose text application or spreadsheet software.

The output data has no header (ST, WT, etc.), + sign and unit (g, kg, etc.). Set the keyboard language of the device to English.

Pairing

  1. Turn on the Bluetooth function of the connection device and power on the scale.
  2. Select the "A&D_HID" device and pair. S/N may have been added after "A&D_HID".
  3. You will not be able to connect if more than 30 seconds have passed without pairing after selecting the device. In that case, power off the scale and try again.

6. Precautions for Use

  • Refer to the instruction manual of the connection device for pairing.
  • The LED lights up when the wireless communication connection is completed.
  • It will connect automatically when the paired device is nearby. When connecting to another device, turn off the unused devices or disconnect.
  • If you cannot communicate, check that the connector is firmly connected. If it still fails, check the scale settings, pairing, and connected devices.

7. Wireless Communication

  • Bluetooth devices is EC2832 (KAGA ELECTRONICS Co., Ltd.) / Bluetooth 5.0 (Bluetooth Low Energy).
  • The effective range communication is 10 m or less in an unobstructed space.
  • If there is an obstacle such as a wall, the range of communication will be shorter.
  • Interference may be caused near the following devices that use the 2.4 GHz frequency band, which is the same as for Bluetooth. Therefore, this device is not suited for uses that require reliability:
    • Wireless LAN
    • Bluetooth devices (such as mobile phones)
    • Home appliances such as microwave ovens

8. Compliance

8-1. Compliance with FCC Rules

This device contains transmitter module FCC ID: 2A6NFEC2832.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

(FCC = Federal Communications Commission in the U.S.A.)

FCC CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

This product is certified as a portable device with FCC Rules. To maintain compliance with RF Exposure requirements, please use within the specification of this product.

8-2. IC

IC RADIATION EXPOSURE STATEMENT FOR CANADA

This device contains transmitter module IC: 28568-EC2832.

This device complies with Innovation, Science and Economic Development Canada license-exempt RSS standards. Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

The French text provided is a translation of these conditions: "Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1) l'appareil ne doit pas produire de brouillage; 2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement."

Models: FG-27, AD-8931, AD-8541-PC, FG-27 Platform Scales, FG-27, Platform Scales, Scales

PDF preview unavailable. Download the PDF instead.

fg-27 Adobe PDF Library 15.0

Related Documents

Preview AD-8526 Ethernet Converter: Instruction Manual and Connectivity Guide
Comprehensive guide for the A&D AD-8526 Ethernet Converter, detailing setup, specifications, cable requirements, and software for connecting weighing instruments to a computer network.
Preview A&D GC Series Counting Scale Quick Start Guide
This Quick Start Guide provides essential information for the A&D GC Series counting scales, including models GC-3K, GC-6K, GC-15K, and GC-30K. Learn about installation, basic operations, and troubleshooting.
Preview A&D HT Series Compact Scale Operating Instructions
Comprehensive operating instructions for A&D HT Series Compact Scales (HT-300, HT-3000, HT-500, HT-5000), covering setup, weighing procedures, specifications, and troubleshooting.
Preview HT Series Compact Scale Operating Instructions
Comprehensive operating instructions for A&D HT series compact digital scales, covering setup, weighing procedures, specifications, and troubleshooting.
Preview A&D HT Series Compact Scale Operating and Calibration Manual
Comprehensive operating instructions and calibration guide for A&D HT series compact scales, including models HT-300, HT-3000, HT-500, and HT-5000. Learn about specifications, battery installation, weighing procedures, automatic power-off, error messages, and advanced calibration methods using a weight or gravity compensation.
Preview A&D AD-4328 Weighing Indicator: Features and Specifications
Detailed information on the A&D AD-4328 weighing indicator, covering its features, specifications, applications, and connectivity options. Learn about its reliability, accuracy, and ease of use for various weighing tasks.
Preview AD4329A-DLC Weighing Indicator Instruction Manual
Comprehensive instruction manual for the A&D AD4329A-DLC digital load cell weighing indicator, covering setup, calibration, functions, and specifications for truck scales.
Preview A&D AD-4406 Weighing Indicator Instruction Manual
Comprehensive instruction manual for the A&D AD-4406 Weighing Indicator, covering installation, features, calibration, functions, and interface specifications.