HT Series Compact Scale Operating Instructions

Cautions

Specifications

ModelCapacity/Readability
HT-300310 x 0.1 g / 10.9 x 0.01 oz
HT-30003100 x 1 g / 109 x 0.1 oz / 6.8 lb x 0.1 oz
HT-500510 x 0.1 g / 17.9 x 0.01 oz / 1.1 lb x 0.01 oz
HT-50005100 x 1 g / 179 x 0.1 oz / 11 lb x 0.1 oz

Keys and Symbols

ON/OFF key
Turns the scale power on/off.
RE-ZERO key
Sets the display to zero.
UNITS key
Changes weighing units, g, lb, oz or lb-oz.
Symbol O (Stable indicator)
Indicates when the reading is stable.
Symbol ZERO (Zero indicator)
Indicates when the scale zero is correct.
Symbol NET (Net weight indicator)
Indicates when the net weight is displayed.
Symbol (Battery level indicator)
Battery remaining level, shown after power-on only.

Installing the Batteries / Connecting the AC Adapter

Before use, remove the insulation tape from the battery compartment.

Installing / Replacing the batteries

  1. Remove the battery cover.
  2. Insert 4 new batteries (AA size) into the battery compartment, taking extreme care of the polarities.
  3. Replace the battery cover.

The batteries provided with the scale are for testing the performance of the scale and may have a limited life.

AC adapter (optional)

Verify that the AC adapter is correct. Open the rubber cap covering the AC adapter jack and plug the AC adapter into the jack.

Weighing Procedures

1. Turning the scale on / off

Press the ON/OFF key to turn the scale on. The scale displays all segments for a few seconds and then displays zero. Press the ON/OFF key again to turn the scale off.

2. Selecting the weighing unit

Press the UNITS key to select the weighing unit. The scale will power up with the weighing unit that was in use when turned off last time.

3. Weighing

  1. Verify that the reading is zero. If not, press the RE-ZERO key to zero the display.
  2. If you use a container for weighing, place an empty container on the weighing pan and press the RE-ZERO key to zero the display.
  3. Place the objects to be weighed on the pan or in the container. When the reading becomes stable, the STABLE indicator O is displayed.

Note

Automatic power-off function

If the scale is left ON and the STABLE indicator O is displayed, the automatic power-off function turns power off after approximately 5 minutes. To disable or enable this function, press the ON/OFF key while pressing the RE-ZERO key. Then PoFFU (disabled) or PoFF (enabled) will be displayed. Select the setting by pressing the RE-ZERO key and press the UNITS key. The scale displays End and returns to the weighing mode.

Error message

E
Overload. Remove the objects from the pan.
----
The scale is out of zero range or unstable when powered on.
Lb
Low battery. Replace the batteries or use the AC adapter.

Calibration and other functions

Please visit the A&D website (http://www.aandd.co.jp/).

PDF preview unavailable. Download the PDF instead.

ht instruction manual 2 Acrobat Distiller 7.0.5 (Windows) .

Related Documents

PreviewA&D HT Series Compact Scale Operating Instructions
Comprehensive operating instructions for A&D HT Series Compact Scales (HT-300, HT-3000, HT-500, HT-5000), covering setup, weighing procedures, specifications, and troubleshooting.
PreviewA&D HT Series Compact Scale Operating and Calibration Manual
Comprehensive operating instructions and calibration guide for A&D HT series compact scales, including models HT-300, HT-3000, HT-500, and HT-5000. Learn about specifications, battery installation, weighing procedures, automatic power-off, error messages, and advanced calibration methods using a weight or gravity compensation.
PreviewA&D AD-4328 Weighing Indicator: Features and Specifications
Detailed information on the A&D AD-4328 weighing indicator, covering its features, specifications, applications, and connectivity options. Learn about its reliability, accuracy, and ease of use for various weighing tasks.
PreviewA&D GC Series Counting Scale Quick Start Guide
This Quick Start Guide provides essential information for the A&D GC Series counting scales, including models GC-3K, GC-6K, GC-15K, and GC-30K. Learn about installation, basic operations, and troubleshooting.
PreviewAD4329A-DLC Weighing Indicator Instruction Manual
Comprehensive instruction manual for the A&D AD4329A-DLC digital load cell weighing indicator, covering setup, calibration, functions, and specifications for truck scales.
PreviewA&D FG-27 Bluetooth Communication Interface: User Guide
Instruction manual for the A&D FG-27 Bluetooth Communication Interface, detailing installation, connection, DIP switch settings, HID function, wireless communication, and compliance information for FG series scales.
PreviewA&D AD-4406 Weighing Indicator Instruction Manual
Comprehensive instruction manual for the A&D AD-4406 Weighing Indicator, covering installation, features, calibration, functions, and interface specifications.
PreviewA&D AD-4212C Series Production Weighing Unit Instruction Manual
Comprehensive instruction manual for the A&D AD-4212C series production weighing units, detailing features, installation, operation, specifications, and troubleshooting for industrial weighing applications.