EcoFlow RIVER 3 Portable Power Station

About This Manual

This user manual is applicable to the following products: RIVER 3, RIVER 3 (230), RIVER 3 (10 ms UPS). The terms "RIVER 3", "RIVER 3 (230)" and "RIVER 3 (10 ms UPS)" in this manual shall refer to EcoFlow RIVER series products. Please note that this manual may be updated without prior notice. You can access the latest version online at EcoFlow Support. Illustrations use the US version as examples; refer to the actual product received. Availability of certain accessories and features may vary by country or region.

Overview

The RIVER 3, RIVER 3 (230), and RIVER 3 (10 ms UPS) are power stations with LiFePO4 batteries. They offer multiple outputs and charging options to meet various needs.

Appearance

The power station features several ports and controls:

Display Screen Indicators:

Error Messages:

Flashing IconProblemSolution
1High TemperatureStop use. Move to a well-ventilated area away from heat sources. Error clears when temperature normalizes.
2Low TemperatureMove to a warmer place. Error clears when temperature normalizes.
3, 5, 6AC Charging OverloadRemove AC charging cable. Error clears automatically; reconnect and try again.
3, 5AC Discharge OverloadRemove connected devices from AC output ports. Error clears automatically; try again.
4Fan BlockedRemove all charging cables, turn off the product. Clear any objects blocking the heat vent before reuse.
5Internal Communication FailureStop use. Remove all charging cables, turn off the product. Wait 1 minute, then turn on again.

For unlisted error messages, check the EcoFlow app. If issues persist, stop use immediately and contact EcoFlow customer service.

Get Started

Power On/Off

Power On: Short press the main power button. Press again to turn off the display screen. The unit enters hibernation and turns off the screen if unused for 5 minutes.

Power Off: Long press the main power button for about 3 seconds.

Tip: The power station cannot be turned off via long press while charging; unplug the charging cable first.

Power Your Appliances

Via USB Output Port: Connect devices directly to the USB ports.

Via AC Output Socket: Press the AC output button to turn the socket on/off. Ensure the total power of connected appliances is less than the socket's rated power (refer to X-Boost instructions for details).

AC Timeout Tip: The AC output port may automatically turn off if idle. For continuous power to devices like refrigerators, set the AC timeout interval to "never" in the EcoFlow app. Regularly check the battery level.

Via DC Output Port (Cigarette Lighter): Press the DC output button to turn the port on/off. Ensure the appliance's starting current requirements are met to avoid startup issues.

Charge Your Power Station

From a Wall Outlet: Connect the AC input port to a wall outlet using the provided AC charging cable. Recommended: use a power socket with a capacity over 10A. Plug directly into the wall outlet, not an extension socket.

  • Maximum AC Input Power: US/JP/BR: 320W; CN/EU/ZA/UK/AU/KR/CH: 305W.

From Solar: Connect the solar input port to solar panels using a solar charging cable (sold separately). Ensure the solar panel's output voltage is less than 30V before connecting.

From a Car Cigarette Lighter: Connect the car input port to your vehicle's cigarette lighter socket using the provided car charging cable. Start the vehicle before charging and ensure the cable is securely connected.

Management

Download EcoFlow App

The EcoFlow app allows for device management, offering:

  • All-in-one control from anywhere.
  • Real-time monitoring of power consumption.
  • Customizable energy schemes.
  • Prompt troubleshooting and firmware updates.

Download at: https://download.ecoflow.com/app

Bind Device and Set Up Internet

After registering an EcoFlow account, bind your devices for remote access. To bind a new device:

  1. Open the EcoFlow app and log in.
  2. Tap the "Add Device" button or + icon to search.
  3. Select your device and follow on-screen instructions for binding and Wi-Fi setup.

Control via Phone

The EcoFlow app manages your devices via Wi-Fi or Bluetooth, adapting to network conditions.

  • With Internet: Stable Wi-Fi allows internet access for settings, firmware updates, and pushes.
  • Without Internet: Limited Wi-Fi allows local management via Bluetooth.

Tip: If unable to discover the power station via Bluetooth, try powering off (long press main power button for 3s), resetting Bluetooth (while off, long press main power button until power-on animation appears twice), and then powering on and retrying the search.

Explore More

X-Boost: Powering High-Wattage Appliances

The AC output sockets support X-Boost, allowing devices up to 600W (450W for JP version) to be powered without overload protection failure.

  • X-Boost is enabled by default. Connect high-wattage appliances to an AC socket.
  • Enable/disable X-Boost in the EcoFlow app.
  • X-Boost is unavailable in bypass mode.

Bypass Mode: Devices receive grid power directly when the station is connected to the grid via AC input and to devices via AC output.

X-Boost Support: Suitable for heating and motor-driven devices. Does not support devices with voltage protection (e.g., precise instruments). Test compatibility with your devices.

Backup for Essential Devices

Use the power station for backup power during outages. It automatically transfers to battery power when the grid fails.

  • How to Use: 1. Connect the station to a wall outlet for grid power. 2. Connect appliances to the station's AC output.
  • Transfer Time: RIVER 3 / RIVER 3 (230) supports Emergency Power Supply (EPS) with a transfer time within 20ms. RIVER 3 (10 ms UPS) supports Uninterrupted Power Supply (UPS) with a transfer time within 10ms.
  • Device Compatibility: Ensure transfer time meets device needs. For RIVER 3/230, do not connect devices requiring uninterrupted power (desktops, NAS, servers). Power only one device (max 300W) at a time to avoid overload.

Storage and Maintenance

Storage

  • Storage Temperature: -10°C to 45°C (14°F-113°F). Avoid temperatures exceeding 45°C or below -10°C.
  • Store in a tidy, dry, well-ventilated place, away from liquids, heat, and sharp objects.
  • For long-term storage, discharge to 0% and charge to 60% every 3 months to maintain battery health.

Note: Warranty is void if the product is not charged or discharged for over 6 months.

Maintenance

  • Cleaning: Use a soft, dry cloth.
  • Maintaining Battery Health: Avoid extended periods of disuse. Charge and discharge every 3 months to increase lifespan.

Safety Instructions and Compliances

Disclaimer

Read and understand this document fully before use. Keep it for future reference. Improper use may cause injury or damage. Use of the product implies acceptance of terms. EcoFlow is not liable for losses due to non-compliance. EcoFlow reserves the right to interpret this document and related materials. This document is subject to change without notice. Visit ecoflow.com for the latest information.

Safety Instructions

  • Transportation: Do not subject to severe impacts, vibrations, or drops. Stop use and turn off power if a severe impact occurs. Do not carry onto a plane.
  • Environment:
    • Do not use near heat sources.
    • Do not place the battery in low air pressure environments.
    • Do not get the product wet or immerse it in liquid. Protect with a waterproof bag in wet conditions.
    • Follow specified temperature requirements for use and storage.
    • Do not use in environments with strong static electricity or magnetic fields.
    • Keep out of reach of children and pets; supervise use near children.
    • Keep away from fumes, smoke, steam, and dust.
    • Store in a tidy, dry, and well-ventilated place.
  • Operation:
    • Do not disassemble, repair, or modify the product yourself. Contact EcoFlow Customer Service for repairs.
    • Always disconnect from external power sources before service.
    • Pull the plug, not the cord, when disconnecting.
    • Do not pierce with sharp objects.
    • Do not insert fingers or hands into the product.
    • Do not insert wires or metal objects to prevent short circuits.
    • Do not block heat dissipation system.
    • Use only official or recommended components/accessories. Contact EcoFlow for replacements.
    • Do not operate with a damaged cord or plug.
    • Do not stack heavy objects on the product.
    • Place on a stable, flat surface.
    • Use a soft, dry cloth for cleaning.
    • AC Timeout Tip: The AC output port may turn off if idle. For critical uses (e.g., refrigerators), set AC timeout to "never" in the EcoFlow app.
    • Medical Equipment Limit: Not intended for life-sustaining medical equipment (e.g., ventilators, ECMO). Consult the equipment manufacturer if using for other medical devices.
    • Medical Equipment Interference: The product generates electromagnetic fields that may affect medical implants (pacemakers, hearing aids, etc.). Contact the equipment manufacturer regarding restrictions. Maintain a safe distance.
    • GROUNDING INSTRUCTIONS: Product must be grounded. Use the provided grounded plug and outlet. WARNING: Improper grounding risks electric shock. Consult an electrician if unsure about grounding or plug fit.
    • Risk of Electric Shock: Never use to power tools to cut or access live parts or wiring.
    • Use in Repair Facility: Do not place on the floor or less than 457 mm (18 inches) above the floor in repair facilities.
    • Do not use damaged or modified battery packs or appliances.
    • For long-term storage, discharge to 0% and charge to 60% every three months. Warranty void if not charged/discharged for over 6 months.
  • In Case of Emergency:
    • Take precautions against electric shock (e.g., wear insulating gloves) before touching.
    • If wet, stop use immediately. Place in a secure, waterproof, ventilated area and contact customer service.
    • If submerged in water, place in a secure, waterproof, ventilated area and keep away until completely dry. Do not reuse; dispose of according to local laws.
    • If the product catches fire, use water/water mist, sand, fire blanket, dry powder, or CO2 extinguisher. Dispose of according to local battery recycling and disposal laws.
  • Recycling and Disposal:
    • Dispose of damaged, malfunctioning, or depleted products properly or recycle them.
    • Dispose of batteries according to local laws and regulations, avoiding household waste to prevent pollution and hazards.
    • If possible, fully discharge the battery (to 0%) before disposal. Contact a professional battery recycling company for proper handling.

Regulatory Compliance

FCC Compliance Statement: Changes not approved by the responsible party may void user authority. This device complies with FCC Part 15, subject to two conditions: (1) it may not cause harmful interference, and (2) it must accept any received interference. Tested for Class A digital device limits for commercial environments. May cause radio frequency energy interference. Operation in residential areas may require user correction. Complies with FCC radiation exposure limits for uncontrolled environments. Install and operate with at least 20 cm distance from the body.

IC Compliance Statement: Maintain 20 cm distance from the body for RF exposure compliance. Complies with Industry Canada licence-exempt RSS standard(s) under two conditions: (1) no interference, and (2) acceptance of any interference. Complies with Canadian ICES-003. (French text follows regarding installation distance and compliance).

CE Marking: EcoFlow Inc. declares this portable power station complies with EU Directives 2014/53/EU, 2014/30/EU, 2011/65/EU(RoHS), (EU) 2015/863(RoHS). Full EU Declaration of Conformity available at: http://www.ecoflow.com/eu/eu-compliance. The EU disposal marking indicates proper recycling to prevent environmental damage and promote sustainable reuse; return to an appropriate collection point or retailer.

Appendix

What's in the Box

  • 1. RIVER 3 / RIVER 3 (230) / RIVER 3 (10 ms UPS)
  • 2. AC Charging Cable
  • 3. Car Charging Cable
  • 4. Manuals & Warranty card

Accessories

Learn More

Specifications

General
ModelRIVER 3/RIVER 3 (10 ms UPS): EFR705
RIVER 3 (230): EF-RV-H01-1
Net WeightApprox. 3.5 kg (7.72 lb)
Dimensions (W×D×H)Approx. 255 × 212 × 113 mm (10.04 × 8.35 × 4.45 in.)
Output
AC Output Wave FormPure sine wave
AC Output (Discharge Only)US/BR: 120V~60Hz, 300W total
JP: 100V~50/60Hz, 300W total
CN: 220V~50Hz, 300W total
KR: 220V~60Hz, 300W total
EU/ZA/UK/AU/CH: 230V~50Hz, 300W total
AC Output (Bypass Mode)US/JP/BR: 100-120V~50/60Hz, 300W total
CN/EU/ZA/UK/AU/KR/CH: 220-240V~50/60Hz, 300W total
USB-A Output5V-2.4A, 12W Max per port, 24W total
USB-C OutputPD3.0, QC3.0
5/9/12/15V-3A Max, 20V=5A Max, 100W Max
DC Output12.6V-10A, 126W Max
Total Output Power550W
Input
AC InputUS/JP/BR: 100-120V~50/60Hz, 6.5A Max
CN/EU/ZA/UK/AU/KR/CH: 220-240V~50/60Hz, 3.0A Max
Solar Input11-30V-8A, 110W Max
Car Input12/24V-8A, 100W Max
Battery Info
Rated CapacityRIVER 3/RIVER 3 (10 ms UPS): 245Wh 19.2V-12.8Ah
RIVER 3 (230): 230Wh 19.2V-12.0Ah
Cell ChemistryLFP (LiFePO4)
Cycle LifeThe battery maintains 80%+ SoH (State of Health) after 3000 cycles at 0.5C/0.5C at 25°C (77°F)
Protection TypeOver Voltage Protection, Overload Protection, Over Temperature Protection, Short Circuit Protection, Low Temperature Protection, Low Voltage Protection, Overcurrent Protection
Environment Temperature
Optimal Operating Temperature20°C-30°C (68°F-86°F)
Charge Temperature0°C-45°C (32°F-113°F)
Discharge Temperature-10°C to 45°C (14°F-113°F)
Storage Temperature-10°C to 45°C (optimal: 20°C-30°C)
14°F-113°F (optimal: 68°F-86°F)
Communications
MethodWi-Fi, Bluetooth
Wi-Fi (2.4G)Frequency:
• CN/BR/MX: 2400-2483.5 MHz
• EU/UK/JP/KR/AU: 2412-2472 MHz/2422-2462 MHz
• TW/US/CA: 2412-2462 MHz/2422-2452 MHz
Maximum Output Power:
• CN: <20dBm
• US: 0.5297W
• CA: 0.5297W
• JP: 2.921mW/MHz
• EU: 17.50dBm
• UK: 17.50dBm
• AU: 17.50dBm
BluetoothFrequency:
• CN/BR/MX: 2400-2483.5 MHz
• EU/UK/TW/US/CA/JP/AU/KR: 2402-2480 MHz
Maximum Output Power:
• CN: <20dBm
• US: 0.1076W
• CA: 0.1076W
• JP: 3.67mW
• EU: 9.50dBm
• UK: 9.50dBm
• AU: 9.50dBm
Other
Operating Altitude≤2000 m
Models: RIVER 3, RIVER 3 Portable Power Station, Portable Power Station, Power Station

File Info : application/pdf, 18 Pages, 1.09MB

PDF preview unavailable. Download the PDF instead.

EcoFlow-RIVER-3-Portable-Power-Station User-Manual

References

GPL Ghostscript 10.05.0

Related Documents

Preview EcoFlow RIVER 3 Portable Power Station User Manual
Comprehensive user manual for the EcoFlow RIVER 3 portable power station, covering setup, operation, features like X-Boost and emergency power supply, maintenance, safety, and specifications.
Preview EcoFlow RIVER 3 Plus Portable Power Station User Manual
Comprehensive user manual for the EcoFlow RIVER 3 Plus and RIVER 3 Plus (270) portable power stations. Learn about setup, operation, features like X-Boost, safety, maintenance, and specifications.
Preview EcoFlow RIVER 3 Plus Portable Power Station User Manual
This user manual provides comprehensive instructions for the EcoFlow RIVER 3 Plus and RIVER 3 Plus (270) portable power stations. It covers product overview, getting started, operation, management features, expansion capabilities, safety guidelines, and technical specifications.
Preview EcoFlow RIVER 3 Plus User Manual
Comprehensive user manual for the EcoFlow RIVER 3 Plus portable power station, covering setup, operation, management, safety, and technical specifications.
Preview EcoFlow RIVER Portable Power Station User Manual
Comprehensive user manual for the EcoFlow RIVER portable power station, detailing specifications, safety guidelines, operation, charging methods (AC, solar, car), app control, troubleshooting, and maintenance for optimal performance and longevity.
Preview EcoFlow RIVER 600 MAX User Guide: Portable Power Station
Comprehensive user guide for the EcoFlow RIVER 600 MAX portable power station, covering setup, features, safety, charging, app integration, and technical specifications.
Preview EcoFlow DELTA 3: Manuale Utente e Guida Completa
Scopri il manuale utente per la power station portatile EcoFlow DELTA 3. Informazioni dettagliate su funzionamento, ricarica, specifiche tecniche e funzionalità avanzate per un uso ottimale.
Preview ECOFLOW RIVER 2 Pro Portable Power Station User Manual
This comprehensive user manual guides users through the operation, safety, and maintenance of the ECOFLOW RIVER 2 Pro portable power station (Model: EFR620). It details specifications, charging methods, advanced features, and troubleshooting.