COMPONENTS

  • Filter drier shipped loose for installation flexibility
  • Service valves positioned for quick installation with 45 degree gauge ports
  • Indoor coil orifice shipped with outdoor unit for correct match
  • Charged for 15 ft. of line set
  • Factory installed high and low pressure switches
  • Sealed contactor with lugs

DESIGN

  • Designed for ambients up to 125°F

ACCESSORIES

  • Low ambient control
  • Thermal expansion valve kits
  • Crankcase heater
  • Hard start kit
  • Sound blanket
  • Loss of charge kit
  • Time delay
  • Short cycle protection
  • Freezestat kit

COMPRESSOR

  • High-efficiency scroll compressor
  • R410a refrigerant
  • Grommet-mounted compressor for quiet operation
  • Internally protected against high temperature motor overload conditions
  • Heavy-duty compressor sound blanket for quiet operation (optional accessory)

CABINET

  • Full metal louvered panel with 2 screws to remove for ease of coil cleaning and service
  • Corner-mounted controls for easy service
  • Rounded corners for safety and attractive, clean appearance
  • Baked polyester paint finished over galvanized steel for maximum durability
  • Removable PVC-coated wire fan discharge grill
  • External gauge ports for easy service

COILS

  • Enhanced aluminum fins and copper tubing for high efficiency and capacity
  • Raised coil prevents debris from collecting in bottom of coil and causing loss of airflow

WARRANTY

10 year limited warranty on compressor, 10 year limited warranty on all parts, extended warranty available*

*Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. See full warranty at www.alliedair.com for terms, conditions and exclusions.

NOTE

For the latest ratings, please see www.alliedratings.com or www.AHRIdirectory.org

Intertek ETL Listed LogoAHRI Certified LogoAHRI Certified Logo

MODEL NUMBER GUIDE

4 SCU 13 LE 1 24 P - 5 A

PHYSICAL AND ELECTRICAL DATA

ModelVoltage/Hz/ PhaseVoltage RangeMin. Circuit Amp.Max. Over Current Device (amps)CompressorFan Motor
Rated Load (amps)Locked Rotor (amps)Rated Load (amps)Rated HPNom. RPM
4SCU13LE118P-5208-230/60/1197-25310.9158.1390.71/101010
4SCU13LE124P-5208-230/60/1197-25314.12010.7530.71/101010
4SCU13LE130P-5208-230/60/1197-25315.62511.6591.11/51090
4SCU13LE136P-5208-230/60/1197-25320.13515.2701.11/51090
4SCU13LE142P-5208-230/60/1197-25328.14521.1901.71/4825
4SCU13LE148P-5208-230/60/1197-25331.95024.11001.71/4825
4SCU13LE160P-5208-230/60/1197-25329.45022.11251.71/4830

UNIT DIMENSIONS (IN.)

Model No.Dimensions A - widthDimensions B - depthDimensions C - HeightShipping Weight (lbs.)
4SCU13LE118P-524.7526.7525.75140
4SCU13LE124P-524.7526.7525.75137
4SCU13LE130P-524.7526.7529.75149
4SCU13LE136P-524.7526.7529.75157
4SCU13LE142P-529.3831.2529.75201
4SCU13LE148P-529.3831.2533.75204
4SCU13LE160P-529.3831.2529.75231

Note: Weights listed are unit weights with packaging. Dimensions listed are unit sizes w/o packaging.

Diagram of an outdoor air conditioning unit with dimensions labeled A, B, and C

SOUND RATINGS

ModelSound Power¹Estimated Sound Pressure (dBA)²
3.3 Feet (1 Meter)6.6 Feet (2 Meters)9.8 Feet (3 Meters)
4SCU13LE118P-572645854
4SCU13LE124P-572645854
4SCU13LE130P-574666056
4SCU13LE136P-574666056
4SCU13LE142P-576686258
4SCU13LE148P-577696359
4SCU13LE160P-578706460

¹ Rated in accordance with AHRI standard 270 (2015). AHRI Standard 270 establishes a method of rating outdoor unitary equipment in terms of Sound Power.

² Rated in accordance with AHRI standard 275 (2010). AHRI Standard 275 provides the calculations for estimating the A-Weighted Sound Pressure at a given distance from the equipment. That is a more useful number because that is what humans will hear.

³ Based only on distance factor; other factors may change this value such as: Unit location (reflective surfaces adjacent to the unit), Barrier shielding sources, Sound path/elevation, Outside noise sources

ACCESSORIES

System AccessoryWhere UsedKit NumberPurpose
Liquid Line solenoidAll models60M52Prevents liquid migration to the compressor especially for high liquid riser applications
Low ambient (cooling operation)All models34M72Enables cooling demand down to 30 °F. Will require freeze stat, CC heater and TXV
Compressor Short Cycle protectorAll models47J27Delays compressor start 5-7 minutes to prevent short cycling
Hard Start1810J42Scroll compressors usually do not require hard start; maybe needed for utility brown-out or low voltage areas
Hard Start24 thru 6088M91
Crankcase Heater18, 24, 30, 3693M04Prevents liquid migration to compressor in cold weather
Crankcase Heater42, 48, 6093M05
Sound CoverFactory InstalledLowers compressor sound level
Loss of Charge KitFactory InstalledProtects the compressor if refrigerant charge is too low
Additional System Accessories (indoor section)
TXV Kit18, 24, 30 36, 42, 48 60H4TXV01 H4TXV02 H4TXV03TXVs provide superior refrigerant flow control, comfort and efficiency compared to pistons
Outdoor Thermostat - electric heatAll models10Z23Prevents electric heat operation above specific ambient conditions
Outdoor Thermostat - Mounting boxAll models31461Mounting box for outdoor thermostat
Freeze statAll models93G35Protects the compressor at low suction pressure conditions
Over flow switchAll models11U75Turn the system off, if condensate water overflows due to clogged drain pipes
Blower time delayAll models58M81Improves system efficiency and comfort
Single point power supplyAll models21H39Provide single power source in one junction box
Auxiliary blower relayAll models85W66Maybe required to select multiple indoor blower speeds

REFRIGERATION DATA

Outdoor ModelCharge (oz) ⁵Refrigerant ConnectionOutdoor (DTC) ⁶Refrigerant Line SizeIndoor Expansion Device
SuctionLiquidSuctionLiquidSuctionLiquidPistonTXV¹
4SCU13LE118P-5625/83/83/43/85/8 or 3/4 ³3/8 or 1/4 ²0.053H4TXV01
4SCU13LE124P-5705/83/83/43/85/8 or 3/4 ³3/8 or 1/4 ²0.057H4TXV01
4SCU13LE130P-5823/43/83/43/83/43/80.063H4TXV01
4SCU13LE136P-5843/43/87/83/83/43/80.072H4TXV02
4SCU13LE142P-51043/43/87/83/83/43/80.074H4TXV02
4SCU13LE148P-517/83/87/83/87/83/80.082H4TXV02
4SCU13LE160P-51447/83/87/83/87/8 or 11/8 ⁴3/80.090H4TXV02

¹ Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required.

² Use 3/8 if over 24 feet of line set

³ Use 3/4 if over 24 feet of line set

⁴ Use 1 1/8 if over 24 feet of line set. Adapter provided with OD unit

⁵ Charged for 15 ft of line set

⁶ DTC = Designated Tested Combination

COOLING PERFORMANCE WITH DTC¹

Outdoor ModelIndoor ModelCapacity (BTUH)EERSEER
4SCU13LE118P-5E*1P24(A,B)+TDR176001113
4SCU13LE124P-5E*1P24(A,B)+TDR228001113
4SCU13LE130P-5E*1P24(A,B)+TDR2800010.513
4SCU13LE136P-5E*1P36(B,C)+TDR3400010.513
4SCU13LE142P-5E*1P43C+TDR4000010.513
4SCU13LE148P-5E*1P49C+TDR470001113
4SCU13LE160P-5E*1P49C+TDR5700010.513

¹ DTC = Designated Tested Combination

NOTE: For the latest ratings, please see www.alliedratings.com or www.AHRIdirectory.org

COOLING PERFORMANCE EXTENDED RATINGS

Outdoor ModelIndoor ModelIndoor Temp DB/ WB °F65°82°95°105°115°
Btuh S/TkWBtuh S/TkWBtuh S/TkWBtuh S/TkWBtuh S/TkW
4SCU13LE118P-5E*1P2485/7223,5000.6321,2000.6520,7000.6818,5000.7018,0000.73
80/6721,6000.6820,6000.7019,0000.7318,0000.7816,6000.81
75/6320,2000.7418,5000.7617,0000.8015,1000.8314,2000.88
75/5718,2001.0016,3001.0015,7001.0014,3001.0013,4001.00
4SCU13LE124P-5E*1P2485/7229,5000.6327,4000.6525,9000.6823,5000.7222,4000.73
80/6727,2000.7025,3000.7223,6000.7620,5000.7919,6000.83
75/6325,5000.7324,1000.7521,2000.8019,6000.8117,6000.87
75/5722,8001.0021,6001.0019,2001.0018,4001.0016,6001.00
4SCU13LE130P-5E*1P2485/7235,1000.6233,1000.6531,0000.6728,4000.6926,8000.72
80/6733,0000.6831,5000.6929,5000.7526,5000.7923,8000.82
75/6331,0000.7129,1000.7326,2000.7724,3000.8221,9000.84
75/5729,5001.0026,4001.0024,0001.0022,1001.0019,6001.00
4SCU13LE136P-5E*1P3685/7242,1000.6139,8900.6438,2000.6735,6500.733,1000.73
80/6739,9000.6837,0100.7334,8000.7632,1500.7929,5000.81
75/6337,9000.7134,7270.7532,3000.7829,6000.8226,9000.86
75/5735,8001.0032,5701.0030,1001.0027,1501.0024,2001.00
4SCU13LE142P-5E*1P4385/7252,2000.6149,1000.6546,9000.6544,8000.6941,3000.7
80/6748,3000.6844,2000.7342,3000.7539,2000.7736,4000.79
75/6345,1000.7241,6000.7238,2000.7737,1000.8132,4000.83
75/5740,3001.0038,2001.0035,5001.0034,0001.0032,2001.00
4SCU13LE148P-5E*1P4985/7261,1000.6357,8700.6555,4000.6652,0000.6948,6000.71
80/6756,8000.6953,2300.7150,5000.7346,8000.7643,1000.79
75/6353,3000.7249,4470.7546,5000.7742,8000.8039,1000.83
75/5747,0001.0043,7131.0041,2001.0038,5001.0035,8001.00
4SCU13LE160P-5E*1P4985/7269,8000.6166,4570.6363,9000.6459,9500.6756,0000.69
80/6765,4000.6861,4900.7058,5000.7154,6000.7450,7000.77
75/6361,4000.7156,9230.7353,5000.7549,6500.7845,8000.81
75/5745,4001.0046,7601.0047,8001.0045,6001.0043,4001.00

All specifications and illustrations subject to change without notice and without incurring obligations.

FORM NO. 4SCU13LE-100 (09/2019)

©2019 Allied Air Enterprises LLC, a Lennox International Inc. Company

Printed in the U.S.A.

Allied Air Enterprises Logo and Phone Number

PDF preview unavailable. Download the PDF instead.

FLAGSHIP AIRCONDITIONERS 4SCU13LE SPECSHEET Adobe PDF Library 15.0 Adobe InDesign 14.0 (Windows)

Related Documents

Preview 4SHP13LB 13 SEER Split System Heat Pump Product Specifications
Product specifications and performance data for the Allied Air Enterprises 4SHP13LB 13 SEER Split System Heat Pump, detailing compressor, cabinet, coil, design, accessories, warranty, and comprehensive cooling and heating performance ratings.
Preview BCE3M & BCS3M Series Air Handler Installation Instructions
Comprehensive installation guide for BCE3M and BCS3M series air handlers, covering safety precautions, unit dimensions, installation requirements, electrical connections, operation, maintenance, and warranty information.
Preview Installation and Maintenance Instructions for Allied Air 4SHP13 Series Split System Heat Pump
Comprehensive guide for the installation, startup, operation, and maintenance of the Allied Air 4SHP13 Series Split System Heat Pump. Includes safety warnings, electrical wiring, refrigerant piping, charging procedures, and warranty information.
Preview 95G2UHV Gas Furnace Installation Instructions
Comprehensive installation instructions for the 95G2UHV Warm Air Gas Furnace, covering upflow, horizontal, direct vent, and non-direct vent configurations. Includes safety information, parts arrangement, building code compliance, and detailed installation procedures.
Preview Allied Air 7AH2AE Residential Air Handler Specifications
Comprehensive product specifications, features, technical data, and installation guidelines for the Allied Air 7AH2AE series residential air handlers, covering capacities from 1.5 to 5 tons and optional electric heat up to 25 kW.
Preview Allied Air Enterprises 97G2V Two Stage Variable Speed Gas Furnace Specifications
Explore the detailed specifications, features, and performance data for the Allied Air Enterprises 97G2V Two Stage Variable Speed Gas Furnace, including technical dimensions and operational capabilities.
Preview Allied Air Enterprises New Furnace Platform Accessory Specification Sheet Fall 2010
This document provides detailed specifications for the new furnace platform accessories from Allied Air Enterprises, including products from Armstrong Air, AirEase, Ducane, and Concord for Fall 2010. It covers various furnace models, their features, and corresponding catalog numbers, along with installation and accessory information.
Preview Allied Air Enterprises Equipment Limited Warranty
This document outlines the limited warranty provided by Allied Air Enterprises for their heating and cooling equipment, including coverage details, exclusions, and procedures for claims. It covers both a standard limited parts warranty and an extended 5-year limited parts warranty for residential applications.