Allied Air Enterprises
Revised Accessory Specification Sheet
New Furnace Platform Fall 2010
This document outlines the accessories available for the new furnace platform introduced by Allied Air Enterprises in Fall 2010. It covers products from the Armstrong Air, AirEase, Ducane, and Concord brands.
Armstrong Air & AirEase Fall 2010 Products
Model Description | Cat # | Model Description | Cat # | Model Description | Cat # |
---|---|---|---|---|---|
"96% Modulating" A96MV 409 Stainless Steel Primary Heat Exchanger, 1 Stage Heat, Variable Speed Blower Motor |
67W09 - 67W18 | "95% Stainless" A9515 409 Stainless Steel Primary Heat Exchanger, 1 Stage Heat, PSC Blower Motor |
67W77 - 67W89 | "95% Efficiency" A951A Aluminized Primary Heat Exchanger, 1 Stage Heat, PSC Blower Motor |
66W64 - 66W76 |
"93% Efficiency" A931A Aluminized Primary Heat Exchanger, 1 Stage Heat, PSC Blower Motor |
66W51 - 66W63 | "80% Variable Speed" A802V 2 Stage Heat, Variable Speed Blower Motor |
66W38 - 66W49 | "80% Efficiency" A801 1 Stage Heat, PSC Blower Motor |
66W12 - 66W35 |
Ducane & Concord Fall 2010 Products
Model Description | Cat # | Model Description | Cat # | Model Description | Cat # |
---|---|---|---|---|---|
"Value 95%" 95G1 Aluminized Primary Heat Exchanger, 1 Stage Heat, PSC Blower Motor |
67W55 - 67W67 | "Value 92%" 92G1 Aluminized Primary Heat Exchanger, 1 Stage Heat, PSC Blower Motor |
67W42 - 67W54 | "Value 80%" 80G1 1 Stage Heat, PSC Blower Motor |
67W19 - 67W35 |
"Value Variable Speed 80%" 80G2V 2 Stage Heat, Variable Speed Blower Motor |
67W36 - 67W38 |
Nomenclature Charts
Armstrong Air & AirEase Brands Nomenclature
The nomenclature system for Armstrong Air and AirEase furnaces uses a series of codes to identify key features:
- Brand: A = Armstrong Air, AirEase
- AFUE: 80 = 96% Efficiency
- Config: UH = Upflow/Horizontal, DF = Downflow
- Stages: 1 = 1 Stage, 2 = 2 Stage
- Blower: M = Modulation, V = Variable Speed, D = Direct Drive
- BTUH Input: Represents heating input in thousands (e.g., 110 = 110,000 BTU/h)
- Cabinet Width: A = 14.5", B = 17.5", C = 21.0", D = 24.5"
- CFM: Indicates airflow capacity.
- Option Code: Describes features like heat exchanger material (S = Stainless Steel, A = Aluminized) or cooling tonnage (08 = 2 Ton, 12 = 3 Ton, etc.).
- Major Revision Code: Indicates product revisions.
Ducane & Concord Brands Nomenclature
The nomenclature for Ducane and Concord furnaces follows a similar structure:
- AFUE: 92 = 92%, 95 = 95%
- Gas: G = Gas
- Stages: 1 = Single Stage, 2 = Two Stage
- Config: UH = Upflow/Horizontal, DF = Downflow
- BTUH Input: Represents heating input in thousands.
- Cabinet Width: A = 14.5", B = 17.5", C = 21.0", D = 24.5"
- Blower Drive: P = PSC, V = Variable Speed
- CFM: Indicates airflow capacity.
- Option Code: Describes features like Low NOx (L) or cooling tonnage.
- Revision Code: Indicates product revisions.
Return Air Bases
Use: Return air kits are used with upflow/horizontal furnaces in upflow applications to provide an additional return air opening. They allow for single side entry on 5-ton air systems.
Kit Contains:
- 1 - Return Air Base (includes front plate, back plate, base plate, right hand side rail, left hand side rail, patch plate)
- 12 - Screws
Description | Used With | Catalog # | Models |
---|---|---|---|
Return Air Base 14.5" | "A" Width Cabinets | 68W61 | All Upflow/Horizontal Models |
Return Air Base 17.5" | "B" Width Cabinets | 68W62 | |
Return Air Base 21.0" | "C" Width Cabinets | 68W63 | |
Return Air Base 24.5" | "D" Width Cabinets | 68W64 |
Diagrams:
- Front View: Shows the return air base with optional side return opening. Dimensions and airflow direction are indicated.
- Side View: Illustrates the dimensions for the side return air opening, including minimum and maximum measurements.
Horizontal Hanging Kit
Use: The horizontal bracket kit provides support for units installed in horizontal applications with an evaporator coil.
Kit Contains:
- 6 - Brackets
- 1 - Support Rail
- 12 - Washers 1/4"
- 6 - Hex Nuts 1/4"
- 6 - Bolts 1/4" x 1-1/4"
- 12 - Rubber Washers 1-1/4"
- 6 - Screws #8 x 1/2"
Description | Used With | Catalog # |
---|---|---|
Horizontal Hanging Kit | "UH" Models in horizontal applications | 51W10 |
Diagram: Shows the furnace and evaporator coil in the discharge air left position, with brackets indicating placement for support.
Combustible Floor Bases
Use: When a downflow unit is installed on a combustible floor, a downflow combustible flooring base must be installed between the furnace and the floor.
Kit Contains:
- 1 - Insulated additive base
Description | Used With | Catalog # | Models |
---|---|---|---|
Downflow Combustible Flooring Base 14.5" | "A" Width Cabinets | 11M59 | All Downflow Models |
Downflow Combustible Flooring Base 17.5" | "B" Width Cabinets | 11M60 | |
Downflow Combustible Flooring Base 21.0" | "C" Width Cabinets | 11M61 |
Installation Steps:
- Cut correct size floor opening.
- Set downflow combustible floor base into opening.
- Set supply air plenum into floor base.
- Set furnace.
Diagram: Illustrates the unit, supply air plenum, combustible floor base, and properly sized floor opening.
Flush Mount Termination Kit (US Only)
Use: Termination Kit 51W11 is used to isolate intake and exhaust pipes as they exit the wall of the structure. The kit may be used with either 2", 2-1/2" or 3" vent systems.
Kit Contains:
- 1 - Flush mount termination
- 1 - 1-1/2" accelerator
- 1 - Template
- 4 - Screws #10 x 2-1/2"
- 4 - Anchors
Description | Used With | Catalog # |
---|---|---|
2" & 3" Flush Termination Kit | All High Efficiency Furnaces (90%+) | 51W11 |
Diagrams:
- Figure 1: Shows flush-mount wall termination options for exhaust and air intake, including vertical up and horizontal left/right configurations.
- Illustrates furnace intake and exhaust pipes connecting to the flush-mount termination, with a 1-1/2" accelerator for specific units.
Concentric Termination Kits (US Only)
Use: Concentric termination kit isolates intake and exhaust pipes as they exit the structure.
Kit Contains:
- 1 - Rain cap
- 1 - Intake SDR-26 pipe
- 1 - Exhaust SDR-26 pipe
- 1 - Concentric fitting
Description | Used With | Catalog # |
---|---|---|
1-1/2" Concentric Vent Kit | All High Efficiency Furnaces (90%+) see installation instructions for proper sizing | 71M80 |
2" Concentric Vent Kit | All High Efficiency Furnaces (90%+) see installation instructions for proper sizing | 69M29 |
3" Concentric Vent Kit | All High Efficiency Furnaces (90%+) see installation instructions for proper sizing | 60L46 |
Diagrams:
- Side Wall Termination: Shows securing strap, intake air, exhaust, and outside wall, with dimensional guidelines for snow accumulation and grade.
- Rooftop Termination: Depicts rooftop termination with flashing, clamp, sheet metal strap, intake air, and exhaust air, including dimensional guidelines.
External Filter Rack Kits
Use: Installing 1" cleanable or disposable filters externally on the side.
Kit Contains (for 1 pack kit):
- 1 - Filter assembly frame
- 1 - Air filter
- 4 - Sheet metal screws
Description | Catalog # | Models |
---|---|---|
1 pack External Filter Kit (16 x 25) | 1.841018 | Upflow / Horizontal |
10 pack External Filter Kit (16 x 25) | 1.841039 |
Diagram: Illustrates filter rack installation, showing the filter rack, filter rack mounting hole, screw, front of cabinet, and corner embossments.
Gas Conversion Kit (Natural to LP Gas Conversion Kit)
Use: For field conversion from natural gas to LP gas.
For 96% Modulating and 80% 2 Stage Variable Speed
Kit Contains:
- 1 - Gas valve
- Required Main burner orifices
- 1 - Gas converter sticker
- 1 - Nameplate conversion sticker
Description | Used With | Catalog # | Models |
---|---|---|---|
Natural to LP Conversion Kit | A96MV | 68W77 | Armstrong Air & AirEase |
Natural to LP Conversion Kit | A802V - 80G2V | 68W76 | All |
For 90% and 80% Single Stage
Kit Contains:
- Required Main burner orifices
- 1 - Gas converter sticker
- 1 - Nameplate conversion sticker
- 1 - LP Spring
Description | Used With | Catalog # |
---|---|---|
Natural to LP Conversion Kit | A93 - 95G - 92G - 95G | 68W75 |
Natural to LP Conversion Kit | A80 - 80G | 72W47 |
Night Service Kits
Use: Common service components packaged conveniently for servicing contractors.
Kit Catalog # | 68W80 | 68W81 | 68W82 |
---|---|---|---|
Description | Single Stage | Two Stage | Modulating |
Used With | A80 - 80G A93 - 92G A95 - 95G |
A802V - 80G2V | A96MV |
Brands | All | All | Armstrong Air & AirEase |
Control Ignition | R10385-01 | R103069-01 | 63W58 |
Gas Valve | 73W17 | 69W44 | 72W34 |
Igniter | 70W16 | 70W16 | 70W16 |
Transformer | 42132 | 42132 | 42132 |
Flame Sensor | 69W43 | 69W43 | 69W43 |
Additional Information
Call Tech Support @ 800-515-3501
- High Altitude Conversion Kits
- LP to Natural Conversion Kits
Coming Soon!
- Low Temperature Condensate Kits
- ULCS636 Canadian Vent Kits
- Retrofit Adapter Kits
- Fresh Air Kits for 80% 2 Stage (Armstrong Air and AirEase only)
- Downflow Filter Box Kit
Related Documents
![]() |
Allied Air Enterprises Equipment Limited Warranty This document outlines the limited warranty provided by Allied Air Enterprises for their heating and cooling equipment, including coverage details, exclusions, and procedures for claims. It covers both a standard limited parts warranty and an extended 5-year limited parts warranty for residential applications. |
![]() |
95G2UHV Gas Furnace Installation Instructions Comprehensive installation instructions for the 95G2UHV Warm Air Gas Furnace, covering upflow, horizontal, direct vent, and non-direct vent configurations. Includes safety information, parts arrangement, building code compliance, and detailed installation procedures. |
![]() |
Allied Air Enterprises 97G2V Two Stage Variable Speed Gas Furnace Specifications Explore the detailed specifications, features, and performance data for the Allied Air Enterprises 97G2V Two Stage Variable Speed Gas Furnace, including technical dimensions and operational capabilities. |
![]() |
BCE3M & BCS3M Series Air Handler Installation Instructions Comprehensive installation guide for BCE3M and BCS3M series air handlers, covering safety precautions, unit dimensions, installation requirements, electrical connections, operation, maintenance, and warranty information. |
![]() |
4SCU13LE 13 SEER Split System Air Conditioner Specifications Detailed specifications for the 4SCU13LE 13 SEER Split System Air Conditioner, including components, design, compressor, cabinet, coils, warranty, physical and electrical data, unit dimensions, sound ratings, accessories, refrigeration data, and cooling performance ratings. |
![]() |
97G2E Two Stage High Efficiency Constant Torque Gas Furnace Product Specifications Detailed product specifications for the Allied Air Enterprises 97G2E series of two-stage, high-efficiency, constant torque gas furnaces, including model guides, electrical data, blower performance, dimensions, and accessories. |
![]() |
4SHP13LB 13 SEER Split System Heat Pump Product Specifications Product specifications and performance data for the Allied Air Enterprises 4SHP13LB 13 SEER Split System Heat Pump, detailing compressor, cabinet, coil, design, accessories, warranty, and comprehensive cooling and heating performance ratings. |
![]() |
Installation and Maintenance Instructions for Allied Air 4SHP13 Series Split System Heat Pump Comprehensive guide for the installation, startup, operation, and maintenance of the Allied Air 4SHP13 Series Split System Heat Pump. Includes safety warnings, electrical wiring, refrigerant piping, charging procedures, and warranty information. |