Fermax MEET Marine Panel
Quick Start and Installation Guide
Connection Terminals
POWER INPUT: 12 Vdc power supply for cases where LAN PoE is not available.
OUTPUT: Relay output for door opener control.
- NC: Normally closed contact.
- NO: Normally open contact.
- C: Common.
NOTE: NC and C contacts are duplicated and internally connected.
EX PROXIMITY:
- (WD0-WD1) Wiegand input/output.
- (+5V, -) 5 Vdc auxiliary output.
EXIT BUTTON / FIRE / DOOR SENSOR:
- (EXIT, -) Connection for interior opening button.
- (FIRE, -) Dry contact input for fire alarm activation and block door unlocking.
- (DS, -) Connection for door open sensor.
RS485: R485 output for module Ref.1491 / Ref.1490 / Ref.1494 / Ref.9545.
RJ 45 NETWORK: RJ 45 connector for LAN.
Basic Diagrams
Diagram 1: Using PoE Switch
A diagram illustrates the connection using a PoE Switch. It shows the MARINE PANEL receiving a +12V input. The panel's RJ45 Network port is connected to a 'Switch PoE'. This PoE switch also connects to an 'Electric lock' and an 'Electric lock power supply', indicating that the PoE switch powers both the panel and the electric lock.
Diagram 2: Using Non-PoE Switch
A diagram illustrates the connection using a non-PoE switch. It shows the MARINE PANEL receiving a +12V input, powered by a separate FERMAX Ref. 4813 (12 Vdc 2A) power supply. The panel's OUTPUT terminals are connected to control an 'Electric lock'. A separate 'Electric lock power supply' is also shown, emphasizing that the panel and the lock should not share the same power source.
Basic Programming from PC
Programming is done via a PC on the same LAN using a web browser (Chrome recommended), accessing the panel's IP.
Default IP: 10.1.0.1
PC IP Requirements: Must be in the same range as the panel's IP (e.g., 10.X.X.X
with subnet mask 255.0.0.0
).
To log in, identify yourself with the username and password.
Default Credentials:
- Username:
admin
- Password:
123456
Assign at least the parameters indicated in the following tables. It is necessary to plan the installation in advance to define the parameters for each device.
General Settings
1. LANGUAGE: Select the desired language (default ENGLISH).
2. TYPE: Choose BLOCK PANEL or G.E. PANEL. Depending on the selection, the fields below will differ.
- If BLOCK PANEL:
- BLOCK: Block number.
- DEVICE NO: Device number within the block. If only one, leave as 1.
- If G.E. PANEL:
- DEVICE NO: General entrance number. If only one, leave as 1.
Confirm with SAVE.
Network Settings
Indicate the network parameters assigned to this panel:
- IP: Panel IP address.
- MASK: Subnet mask.
- GATEWAY: IP of gateway.
- DNS: Valid DNS IP.
Confirm with SAVE.
On-Screen Information
It is possible to get basic information on the equipment configuration through the screen.
1. Dial 9999
followed by the 'B' key.
2. The screen will display information about panel settings:
- Firmware version.
- GENERAL settings.
- Serial number.
- MAC address.
- IP address.