Schneider Electric Harmony Timer Relay RE22R2MMU
Product Data Sheet
Model: RE22R2MMU
Product Availability: Non-Stock - Not normally stocked in distribution facility
Main Specifications
Parameter | Value |
---|---|
Range of Product | Harmony Timer Relays |
Discrete output type | Relay |
Product or Component Type | Modular timing relay |
Device short name | RE22 |
Nominal output current | 8 A |
Complementary Specifications
Parameter | Value |
---|---|
Contacts type and composition | 1 C/O timed contact, 1 C/O timed or instantaneous contact |
Time delay type | Power on-delay, On-delay and off-delay, Interval, Off-delay, Symmetrical flashing |
Time delay range | 0.1...1 s, 1...10 s, 1...10 min, 6...60 s, 1...10 h, 10...100 h, 6...60 min |
Control type | Rotary knob front panel |
[Us] rated supply voltage | 24...240 V AC, 24 V DC |
Voltage range | 0.85...1.1 Us |
Supply frequency | 50...60 Hz +/- 5% |
Connections - terminals | Screw terminals, 2 x 1.5 mm² with cable end, Screw terminals, 2 x 2.5 mm² without cable end |
Tightening torque | 5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1 |
Housing material | Self-extinguishing |
Repeat accuracy | +/- 0.5% IEC 61812-1 |
Temperature Drift | +/-0.05 %/°C |
Voltage drift | +/-0.2%/V |
Setting accuracy of time delay | +/- 10% of full scale 25 °C IEC 61812-1 |
Control signal pulse width | 30 ms |
Insulation resistance | 100 MOhm 500 V DC IEC 60664-1 |
Recovery time | 120 ms on de-energisation |
Immunity to microbreaks | 10 ms |
Power consumption in VA | 50 VA 240 V AC |
Power consumption in W | 0.7 W 24 V DC |
Breaking capacity | 2000 VA |
Minimum switching current | 10 mA 5 V |
Maximum switching current | 8 mA |
Maximum switching voltage | 250 V |
Electrical durability | 100000 cycles for resistive load, 8 A at 250 V, AC |
Mechanical durability | 10000000 cycles |
Rated impulse withstand voltage | 5 kV 1.2...50 µs IEC 60664-1, 5 kV IEC 61812-1 |
Power on delay | 100 ms |
Safety reliability data | MTTFd = 182.6 years, B10d = 170000 |
Mounting position | Any position in relation to normal vertical mounting plane |
Mounting support | 35 mm DIN rail conforming to IEC 60715 |
Status LED | Green LED (timing in progress), Green LED steady (power ON), Yellow LED (relay energised) |
Function available | A: Power on-delay relay - 2 C/O, Ac: On-delay and off-delay relay w/ control signal - 2 C/O, At: Power on-delay relay w/ pause/summation (Y1) - 2 C/O, B: Single interval relay w/ control signal - 2 C/O, Bw: Double interval relay w/ control signal - 2 C/O, C: Off-delay relay w/ control signal - 2 C/O, D: Symmetrical flashing relay (starting pulse-off) - 2 C/O, Di: Symmetrical flashing relay (starting pulse-on) - 2 C/O, H: Interval relay - 2 C/O, Ht: Interval relay w/ pause/summation (Y1) - 2 C/O |
Width | 0.9 in (22.5 mm) |
Net Weight | 0.20 lb(US) (0.09 kg) |
Control Type | With test button |
Number of functions | 10 |
Environment
Parameter | Value |
---|---|
Dielectric strength | 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1 |
Standards | IEC 61812-1, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, IEC 61000-6-4 |
Directives | 2004/108/EC - electromagnetic compatibility, 2006/95/EC - low voltage directive |
Product Certifications | cULus, CSA, CE, CCC, RCM, GL, EAC |
Ambient Air Temperature for Operation | -4...140 °F (-20...60 °C) |
Ambient Air Temperature for Storage | -22...140 °F (-30...60 °C) |
IP degree of protection | IP40 housing: conforming to IEC 60529, IP20 terminal block: conforming to IEC 60529, IP40 front face: conforming to IEC 60529 |
Vibration resistance | 20 m/s² (f= 10...150 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 15 gn 11 ms IEC 60068-2-27 |
Relative humidity | 93%, without condensation IEC 60068-2-30 |
Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2, Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2, Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4, Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4, Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5, Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5, Radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6, Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3, Immunity to microbreaks and voltage drops - test level: 30% (500 ms) conforming to IEC 61000-4-11, Immunity to microbreaks and voltage drops - test level: 100% (20 ms) conforming to IEC 61000-4-11, Conducted and radiated emissions class B conforming to EN 55022 |
Ordering and Shipping Details
Parameter | Value |
---|---|
Category | US10CP222376 |
Discount Schedule | 0CP2 |
GTIN | 3606480676581 |
Returnability | Yes |
Country of origin | ID |
Packing Units
Parameter | Value |
---|---|
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 0.98 in (2.500 cm) |
Package 1 Width | 3.23 in (8.200 cm) |
Package 1 Length | 3.74 in (9.500 cm) |
Package 1 Weight | 3.704 oz (105.000 g) |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 40 |
Package 2 Height | 5.91 in (15.000 cm) |
Package 2 Width | 11.81 in (30.000 cm) |
Package 2 Length | 15.75 in (40.000 cm) |
Package 2 Weight | 10.289 lb(US) (4.667 kg) |
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
Environmental footprint
Parameter | Value |
---|---|
Carbon footprint (kg CO2 eq, Total Life cycle) | 53 |
Materials and Substances
Parameter | Value |
---|---|
Packaging made with recycled cardboard | Yes |
Packaging without single use plastic | Yes |
EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
SCIP Number | 7bdc2711-0ad2-427c-8ece-532c5e9f09d7 |
REACH Regulation | REACH Declaration |
California proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Repack and remanufacture
Parameter | Value |
---|---|
Take-back | No |
Dimensions Drawings
Dimensions:
Diagram:
A 2D drawing showing the dimensions of the relay in millimeters and inches. The main body of the relay is shown from the side, with dimensions 79.5 mm (3.13 in) and 83.5 mm (3.29 in). A separate view shows the terminal block side with dimensions 22.9 mm (0.90 in) and 90 mm (3.54 in).
Connections and Schema
Internal Wiring Diagram
Diagram:
A wiring diagram illustrating the internal connections of the relay. It shows terminals labeled A1, Y1, 15, R1, 25/21, A2, 16, 18, 26/22, 28/24, with connections indicated by lines and symbols.
Technical Description
Function A: Power on Delay Relay
Description: The timing period T begins on energization. After timing, the output(s) relay close(s).
Diagram:
A timing diagram shows the input signal U (blue bar), the control signal Y1 (black bars), and the output signals R1/R2 and R2 inst. (black bars) over time T.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function Ac: On- and Off-Delay Relay with Control Signal
Description: After power-up, closing of the control contact Y1 causes the timing period T to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period, the relay closes. When control contact Y1 re-opens, the timing T starts. At the end of this timing period T, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G).
Diagram:
A timing diagram shows the input signal U (blue bar), the control signal Y1 (black bars), and the output signals R1/R2 and R2 inst. (black bars) over time T.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function At: Power on Delay Relay (Summation) with Control Signal
Description: After power-up, the first opening of control contact Y1 starts the timing. Timing can be interrupted each time control contact closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes.
Diagram:
A timing diagram shows the input signal U (blue bar), the control signal Y1 (black bars), and the output signals R1/R2 and R2 inst. (black bars) over time periods t1, t2, t3, with the total time T = t1+t2+t3.
Function B: Interval Relay with Control Signal
Description: After power-up, pulsing or maintaining control contact Y1 starts the timing T. The output relay closes for the duration of the timing period T then reverts to its initial state.
Diagram:
A timing diagram shows the input signal U (blue bar), the control signal Y1 (black bars), and the output signals R1/R2 and R2 inst. (black bars) over time T.
Legend:
- Relay de-energised
- Relay energised
- Output open
- Output closed
- Y1: Control contact
- R1/R2: 2 timed outputs
- R2 inst.: The second output is instantaneous if the right position is selected
- T: Timing period
- U: Supply
Function Bw: Double Interval Relay with Control Signal
Description: On closing and opening of control contact Y1, the output relay closes for the duration of the timing period T.
Diagram:
A timing diagram shows the input signal U (blue bar), the control signal Y1 (black bars), and the output signals R1/R2 and R2 inst. (black bars) over time T.
Function C: Off-Delay Relay with Control Signal
Description: After power-up and closing of the control contact Y1, the output relay closes. When control contact Y1 re-opens, timing T starts. At the end of the timing period, the output(s) relay revert(s) to its/their initial state.
Diagram:
A timing diagram shows the input signal U (blue bar), the control signal Y1 (black bars), and the output signals R1/R2 and R2 inst. (black bars) over time T.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function D: Symmetrical Flasher Relay (Starting Pulse Off)
Description: Repetitive cycle with two timing periods T of equal duration, with output(s) relay changing state at the end of each timing period T.
Diagram:
A timing diagram shows the input signal U (blue bar), the control signal A1Y1 (black bars), and the output signals R1/R2 and R2 inst. (black bars) over multiple time periods T.
Before power-up Y1 should be permanently connected to A1.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function D: Symmetrical Flasher Relay (Starting Pulse On)
Description: Repetitive cycle with two timing periods T of equal duration, with output(s) relay changing state at the end of each timing period T.
Diagram:
A timing diagram shows the input signal U (blue bar), and the output signals R1/R2 and R2 inst. (black bars) over multiple time periods T.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function H: Interval Relay
Description: On energization of the relay, timing period T starts and the output(s) relay close(s). At the end of the timing period T, the output(s) relay revert(s) to its/their initial state.
Diagram:
A timing diagram shows the input signal U (blue bar), and the output signals R1/R2 and R2 inst. (black bars) over time T.
2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
Function Ht: Interval Relay & With Pause / Summation Control
Description: On energisation of power supply, output(s) R close(s) and timing period T starts. The timing can be interrupted / paused each time X1 energizes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state. Reenergization of X1 will also cause output(s) R close(s) if the time has elapsed and restart the same operation as described at the beginning. Except for RE17*, RE22R2MMW, RENF22R2MMW, RE22R2MMU and RE22R2MJU, timing can be interrupted / paused each time Y1 energizes. The second output (R2) can be either timed (when set to "TIMED" or instantaneous (when set to "INST").
Function: 1 Output
Diagram:
A timing diagram shows the input signal U (blue bar), control signal X1 (black bars), and output R1 (black bar) over time periods t1, t2, with the total time T = t1+t2+...
Function: 2 Outputs
Diagram:
A timing diagram shows the input signal U (blue bar), control signal X1 (black bars), and outputs R1, R2, R2 inst. (black bars) over time periods t1, t2, with the total time T = t1+t2+...
Function: 1 Output with Retrigger / Restart Control
Diagram:
A timing diagram shows the input signal U (blue bar), control signal Y1 (black bars), and output R1 (black bar) over time periods t1, t2, with the total time T = t1+t2+...
Function: 2 Outputs with Retrigger / Restart Control
Diagram:
A timing diagram shows the input signal U (blue bar), control signal Y1 (black bars), and outputs R1, R2, R2 inst. (black bars) over time periods t1, t2, with the total time T = t1+t2+...
Technical Illustration
Dimensions
Diagram:
Two views of the Harmony Timer Relay. One shows the side profile with dimensions 79.5 mm (3.13 in) and 83.5 mm (3.29 in). The other shows the terminal side with dimensions 22.9 mm (0.90 in) and 90 mm (3.54 in).
Product benefits / Features
Technical Benefits
Harmony Timer Relay
- Choice of screw terminals for wiring.
- Product reference offering 28 timing functions, 2 outputs, and a wide range of supply voltage (24...240 V AC/DC).
- LED indicators for status monitoring.
- IP50 front panel protection with a removable settings protection cover.
- A Dial-Pointe indicator that enhances ease of operation in environments such as low-light conditions.
- Different mounting styles to meet user preferences: DIN rail mounting (product width 17.5 mm/0.69 in or 22.5 mm/0.89 in) and plug-in modules with sockets.
Features
Harmony Timer Relay
- "Diagnostic button" to check downstream circuit immediately, shortening commission and troubleshooting time.
- Compatible with a wide range of applications including machines, buildings, water segments, and HVAC.
- Wide range of time delay for adjustment: from 0.01 s to 999 hrs.
- Compliant with IEC 60255-1 standard, and a wide array of product certifications such as UL, CE, CSA, EAC.
- Unprecedented accuracy, predictive maintenance, and superior security.
Image of product / Alternate images
Alternative
Diagram:
Two images of the Harmony Timer Relay. The first image shows the relay from a slightly elevated front-left perspective, highlighting the terminal blocks and adjustment dials. The second image shows the relay from a side perspective, emphasizing its slim profile and mounting mechanism.
The second image also shows a close-up of the relay's side, with labels indicating terminal connections such as A1, 15, 25/21, R1, A2, 18, 26/22, 28/24, and Y1. It also displays adjustment dials for time ranges like "5-10min", "0.1-1s", "1-10s", "6-60s", "1-10h", "10-100h", and "6-60min". Output selection for "R1 TIMED", "R2 TIMED", "R2 INST." is also visible.