GRAPHTEC midi LOGGER GL840 Series & GL240
Isolated/Universal Input, Standalone Multi-Channel Datalogger
Setting New Heights in Data Recording
The GRAPHTEC midi LOGGER series offers advanced data recording capabilities with a flexible input system for a wide array of applications, extended memory capacity using an SD memory card, and a maximum sampling interval of up to 10ms.
Key Models:
- ✨ NEW Multi-Input Model: midi LOGGER GL840-M
- ✨ NEW High Voltage Withstand Model: midi LOGGER GL840-WV
- ✨ NEW 10-Channel Portable Model: midi LOGGER GL240
Visit: www.graphteccorp.com
Setting New Industry Standards for It's Class
Accommodates a Wide Variety of Measurements
- Multifunction Analog Input Ports: Features a highly isolated input mechanism to prevent noise interference between channels. Suitable for combined measurements of voltage, temperature, humidity, logic, and pulse signals.
- 4 Channels of Logic/Pulse Inputs: Supports 4-channel logic or pulse signal inputs. Pulse mode enables cumulative, instant, or rotational value measurements for industrial applications.
- Voltage Ranges: From 20mV to 100V.
- Input Types Supported:
- Temperature: Thermocouple types R, S, B, K, E, T, J, N, W; RTD types Pt100, Pt1000, JPt100 (for GL840 only).
- Humidity: 0 to 100%RH (requires optional sensor B-530).
- Logic/Pulse: 4 channels (requires optional input/output cable B-513). Selectable between Logic or Pulse input.
Maximum Sampling Interval of Up to 10ms
Provides faster sampling rates for voltage measurements, achievable when limiting the number of channels in use.
Sampling Interval | Number of Channels | GL840 Measuring (Voltage/Temp) | GL240 Measuring (Voltage/Temp) |
---|---|---|---|
10ms | 1 | Yes / N/A | Yes / N/A |
20ms | 2 | Yes / N/A | Yes / N/A |
50ms | 5 | Yes / Yes | Yes / Yes (10ch) |
100ms | 10 | Yes / Yes | Yes / Yes (10ch) |
200ms | 20 | Yes / Yes | Yes / Yes (10ch) |
500ms | 50 | Yes / Yes | Yes / Yes (10ch) |
1s | 100 | Yes / Yes | Yes / Yes (10ch) |
2s | 200 | Yes / Yes | Yes / Yes (10ch) |
* Chart applicable when data is saved in GBD binary file format. Limited sampling speed applies when using digital sensors and GL100-WL.
Built-in 4GB Flash Memory with SD Card Support
Enables reliable long-term measurement with 4GB internal flash memory and an SD card slot supporting SDHC memory cards up to 32GB.
Model | Sampling | GBD format (20ch) | CSV format (20ch) | GBD format (10ch) | CSV format (10ch) |
---|---|---|---|---|---|
GL840 | 10ms | 31 days | 3 days | N/A | N/A |
50ms | 77 days | 11 days | |||
100ms | 95 days | 16 days | N/A | N/A | |
200ms | 108 days | 21 days | |||
500ms | 270 days | 54 days | N/A | N/A | |
1s | over 365 | 109 days | |||
10s | over 365 | over 365 | N/A | N/A | |
GL240 | 10ms | N/A | N/A | 41 days | |
50ms | 88 days | 12 days | |||
100ms | 103 days | 18 days | |||
200ms | 207 days | 36 days | |||
500ms | over 365 | 91 days | |||
1s | over 365 | 182 days | |||
10s | over 365 | over 365 |
* Figures are approximate. File size is 2GB. Sampling interval is limited by the number of channels in use (10ms: 1ch, 50ms: 5ch, 100ms: 10ch). Limited sampling speed applies when using digital sensors and GL100-WL.
Useful Functions
- Display Options: Waveform display (Analog + Digital), Digital display, Dual display (Current + Past data).
- Bar Chart: Displays integrated data from digital sensors. Supports line charts with specific sensors (e.g., GS-TH, GS-DPA-AC, GS-LXUV).
- Alarm Output Function: Four channel alarm output ports based on set conditions. Requires optional input/output cable (B-513).
- USB Drive Mode: Enables drag-and-drop data transfer to a PC.
- Ring Capture Function: Saves the most recent data when memory is configured in ring mode (1,000 to 2,000,000 data points).
- Relay Capture Function: Continuously saves data to multiple files up to 2GB without data loss until capturing stops.
- Hot-Swapping the SD Memory Card: Allows SD card replacement during data capturing (with exceptions for GL100-WL).
- Navigation Function: Provides a simple interface for measurement and wireless LAN adapter settings.
- Power Sources: Supports AC power adapter, DC supply (with optional cable B-514), and rechargeable battery pack (optional B-569).
- Networking Features: Web & FTP server for external control and monitoring, FTP client for periodic data backup, and NTP client for clock synchronization. Requires LAN connection.
GL840 Expands to Two Models for Application-Specific Use
- Multi-Input Model (midi LOGGER GL840-M): Ideal for temperature measurement with multiple channels.
- High Voltage Withstand Model (midi LOGGER GL840-WV): Suited for stacked high voltage battery applications and high-precision temperature measurement.
Expandable Up to 200 Channels
Standard configuration includes 20 analog input channels, expandable to 200 channels by adding optional 20-channel extension terminal base units (B-566) and input terminal units (B-564 or B-565). The expansion process involves connecting these units in a daisy-chain configuration.
Configuration | GL840 Unit | Connection Cable (B-567) | Terminal Base (B-566) | Input Terminal (B-564/565) |
---|---|---|---|---|
20 channels | 1 set | N/A | N/A | N/A |
40 channels | 1 set | 1 pc | 2 sets | 1 set |
100 channels | 1 set | 1 pc | 5 sets | 4 sets |
200 channels | 1 set | 1 pc | 10 sets | 9 sets |
* Input terminal blocks can be mixed, but overall voltage and accuracy are limited by the B-564 rating.
Three Types of Input Systems Enable Measurement of Various Signals
The midi LOGGER supports basic analog signals, logic/pulse signals, and digital sensors for comprehensive measurement capabilities.
Support Digital Sensors
Digital sensors and input terminal/adapters for the GL100 can connect directly to the GL840. Supported sensors include:
- Temperature/Humidity: GS-TH
- Acceleration/Temperature: GS-3AT
- Carbon Dioxide: GS-CO2
- Illuminance/UV: GS-LXUV
- Voltage/Temperature: GS-4VT
- Thermistor Input Terminal: GS-4TSR
- AC Current Sensor Adapter: GS-DPA-AC
Longer Cables for Input Terminals: Input terminals can be connected directly or via extension cables (up to 20m) for flexible placement.
Dual Port Adapter: The GS-DPA allows simultaneous connection of up to two sensor modules (e.g., Temp/Humidity & Illuminance/UV).
High Performance Software for PC (GL100_240_840-APS)
This software supports the GL840, GL240, and GL100 series, allowing control of up to 10 units and 1000 channels simultaneously. Key features include:
- Measurement Screens: Y-T waveform, digital monitoring, statistical calculations, and bar charts.
- Scheduling Function: Set automatic measurement start and stop times.
- Group Function: Manage multiple units for simultaneous control and data saving.
- File Operation: Merge multiple data files, import data as new channels, and bind data along a time axis.
- Data Format Conversion: Convert GBD format to CSV, with options for compression or saving interval values (average, max, min).
- Warning Function: Send email notifications upon alarm occurrence.
- Statistical Calculation: Compute maximum, minimum, and average values during data capture.
- Report Function: Automatically create daily or monthly reports.
Main Unit Series Specifications
Item | Description | GL840-M/GL840-WV | GL240 |
---|---|---|---|
Model Number | GL840-M/GL840-WV | GL240 | |
Number of Analog Input Channels | Standard Configuration | 20 channels | 10 channels |
Expandable | Up to 200 channels | N/A | |
Number of Analog Input Terminals | Standard Configuration | 1 terminal | N/A |
Expandable | Up to 10 terminals | N/A | |
Type of Analog Input Terminal | Multi-input type, Withstand-voltage type | N/A | |
Port for Digital Sensor | 1 port for GL100 sensor/terminal | N/A | |
External Input/Output | Input (*2) | Trigger or Sampling (1 channel), Logic/Pulse (4 channels) | |
Output (*3) | Alarm (4 channels) | ||
Sampling Interval | 10 ms to 1 hour (10ms to 50ms: voltage only) (*4), External signal | ||
Time Scale of Waveform Display | 1 sec. to 24 hour /division | ||
Trigger, Alarm Function | Trigger Action | Start or stop capturing data by the trigger | |
Repeat Action | Off, On (auto rearmed) | ||
Trigger Source | Start: Off, Measured signal, Alarm, External, Clock, Week or Time; Stop: Off, Measured signal, Alarm, External, Clock, Week or Time | ||
Condition Setting | Combination: AND / OR; Analog signal: Rising (High), Falling (Low), Window-in, Window-out; Logic signal: Pattern; Pulse (number of count): Rising (High), Falling (Low), Window-in, Window-out | ||
Pulse Input Function | Rotation Count (RPM) Mode | Counts pulses per sampling interval and converts to rpm (rotations per minute). Number of pulses for one rotation can be set. | |
Accumulating Count Mode | Accumulates the number of pulses from the start of measurement. | ||
Instant Count Mode | Counts the number of pulses per sampling interval. | ||
Calculation Function | Between Channels | Addition, Subtraction, Multiplication, and Division for analog input. | |
Statistical | Select two calculations from Average, Peak, Maximum, Minimum, RMS. | ||
Interface to PC | Ethernet, USB 2.0 (Hi-speed) | USB 2.0 (Hi-speed) | |
Storage Device | Internal | Built-in 4GB Flash Memory (*6) | |
External | One SD card slot (Supports SDHC memory card, up to 32GB) (*7) | ||
Saved Contents | Captured data, Setting conditions, Screen copy | ||
Capturing Mode | Mode | Normal, Ring, Relay | |
Ring | Saves most recent data (1000 to 2,000,000 points) (*8) | ||
Relay | Saves data to multiple files without losing data until capturing stops. | ||
Replay Data (GBD/CSV) | Replays captured data saved in GL840 | Replays captured data saved in GL240 | |
Scaling (Engineering Unit) Function | Converts measured value to specified engineering unit (Analog voltage: 4 reference points; Temperature: 2 reference points; Pulse count: 2 reference points). | ||
Action During Data Capture | Displaying past data (dual display), Hot-swapping SD card, Saving data between cursors. | ||
Display (LCD) | Size | 7-inch color TFT (WVGA: 800 x 480 dots) | 4.3-inch color TFT (WQVGA: 480 x 272 dots) |
Language | English, French, German, Chinese, Korean, Russian, Spanish, Japanese | ||
Information (*9) | Waveform (Y-T), Digital values, Statistics, Bar chart (GL840 only). | ||
Operating Environment | 0 to 45 ºC, 5 to 85 % RH (non-condensed) | ||
Power Source | AC Adapter | 100 to 240 V AC, 50/60 Hz | |
DC Power | 8.5 to 24 V DC (requires B-514) | ||
Battery Pack | Mountable battery pack (optional B-569: 7.2V DC, 2900mAh) | ||
Power Consumption (*10) | Max. 38 VA | Max. 36 VA | |
External Dimensions (W x D x H mm) | Approx. 240 x 158 x 52.5 (GL840-M) Approx. 240 x 166 x 52.5 (GL840-WV) | Approx. 188 x 117 x 42 | |
Weight (*11) | Approx. 1010 g (GL840-M) Approx. 1035 g (GL840-WV) | Approx. 500 g |
Analog Input Specifications
Item | Model | Input Method | Measurement Range | Accuracy (Voltage) | Accuracy (Temperature - Thermocouple) | Accuracy (Temperature - RTD) |
---|---|---|---|---|---|---|
Voltage | GL840 Series | All channels isolated balanced input (*12), Screw terminal (M3) | 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100 V, 1-5V F.S. | ±0.1% of F.S. | See detailed table below | See detailed table below |
GL240 | 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100 V, 1-5V F.S. | ±(0.05% of F.S. + 10µV) | ||||
Thermocouple | GL840 Series | Type: K, J, E, T, R, S, B, N, W (WRe5-26) Range: 100, 500, 2000 ºC (*13) |
±0.1% of F.S. | |||
GL240 | Type: K, J, E, T, R, S, B, N, W (WRe5-26) | ±0.1% of F.S. | See detailed table below | See detailed table below | ||
RTD | GL840 Series | Type: Pt100 (IEC751), Pt1000 (IEC751), JPt100 (JIS) Range: 100, 500, 2000 ºC (*13) |
±0.1% of F.S. | |||
Humidity | GL840 Series | 0 to 100 % RH (using optional sensor B-530) | N/A | N/A | N/A | |
Filter | Off, 2, 5, 10, 20, 40 (moving average) |
Detailed Temperature Accuracy (Thermocouple)
Type | Measurement Range (*16) | Measurement Accuracy | ||
---|---|---|---|---|
GL840-M (B-564) | GL840-WV (B-565) | GL240 | ||
R/S | 0 ≤ TS ≤ 100 ºC | ±5.2 ºC | ±4.5 ºC | ±5.2 ºC |
100 < TS ≤ 300 ºC | ±3.0 ºC | ±3.0 ºC | ±3.0 ºC | |
R: 300 < TS ≤ 1600 ºC | ±(0.05% of rdg. + 2.0 ºC) | ±2.2 ºC | ±(0.05% of rdg. + 2.0 ºC) | |
S: 300 < TS ≤ 1760 ºC | ±(0.05% of rdg. + 2.0 ºC) | ±2.2 ºC | ±(0.05% of rdg. + 2.0 ºC) | |
B | 400 ≤ TS ≤ 600 ºC | ±3.5 ºC | ±3.5 ºC | ±3.5 ºC |
600 < TS ≤ 1820 ºC | ±(0.05% of rdg. + 2.0 ºC) | ±2.5 ºC | ±(0.05% of rdg. + 2.0 ºC) | |
K | -200 ≤ TS ≤ -100 ºC | ±(0.05% of rdg. + 2.0 ºC) | ±1.5 ºC | ±(0.05% of rdg. + 2.0 ºC) |
-100 < TS ≤ 1370 ºC | ±(0.05% of rdg. + 1.0 ºC) | ±0.8 ºC | ±(0.05% of rdg. + 1.0 ºC) | |
E | -200 ≤ TS ≤ -100 ºC | ±(0.05% of rdg. + 2.0 ºC) | ±1.0 ºC | ±(0.05% of rdg. + 2.0 ºC) |
-100 < TS ≤ 800 ºC | ±(0.05% of rdg. + 1.0 ºC) | ±0.8 ºC | ±(0.05% of rdg. + 1.0 ºC) | |
T | -200 ≤ TS ≤ -100 ºC | ±(0.1% of rdg. + 1.5 ºC) | ±1.5 ºC | ±(0.1% of rdg. + 1.5 ºC) |
-100 < TS ≤ 400 ºC | ±(0.1% of rdg. + 0.5 ºC) | ±0.6 ºC | ±(0.1% of rdg. + 0.5 ºC) | |
J | -200 ≤ TS ≤ -100 ºC | ±2.7 ºC | ±1.0 ºC | ±2.7 ºC |
-100 < TS ≤ 100 ºC | ±1.7 ºC | ±0.8 ºC | ±1.7 ºC | |
100 < TS ≤ 1100 ºC | ±(0.05% of rdg. + 1.0 ºC) | ±0.6 ºC | ±(0.05% of rdg. + 1.0 ºC) | |
N | -200 ≤ TS < 0 ºC | ±(0.1% of rdg. + 2.0 ºC) | ±2.2 ºC | ±(0.1% of rdg. + 2.0 ºC) |
0 ≤ TS ≤ 1300 ºC | ±(0.1% of rdg. + 1.0 ºC) | ±1.0 ºC | ±(0.1% of rdg. + 1.0 ºC) | |
W | 0 ≤ TS ≤ 2000 ºC | ±(0.1% of rdg. + 1.5 ºC) | ±1.8 ºC | ±(0.1% of rdg. + 1.5 ºC) |
R.J.C. | ±0.5 ºC | ±0.3 ºC | ±0.5 ºC |
Detailed Temperature Accuracy (RTD)
Type | Measurement Range (*16) | Measurement Accuracy | ||
---|---|---|---|---|
GL840-M (B-564) | GL840-WV (B-565) | GL240 | ||
Pt100 | -200 ≤ TS ≤ 100 ºC | ±1.0 ºC | ±0.6 ºC | N/A |
100 < TS ≤ 500 ºC | ±0.8 ºC | |||
500 < TS ≤ 850 ºC | ±1.0 ºC | |||
Pt1000 | -200 ≤ TS ≤ 100 ºC | ±0.8 ºC | ±0.6 ºC | |
100 < TS ≤ 500 ºC | ±0.8 ºC | |||
JPt100 | -200 ≤ TS ≤ 100 ºC | ±0.8 ºC | ±0.6 ºC | |
100 < TS ≤ 500 ºC | ±0.8 ºC |
Technical Details
- A/D Converter: Sigma-Delta type, 16 bits (effective resolution: 1/40000 of the measuring full range).
- Maximum Input Voltage: Varies by range and model (e.g., 60 Vp-p to 110 Vp-p for channels, 60 Vp-p to 300 Vp-p for channel/GND).
- Maximum Withstand Voltage: Varies by configuration (e.g., 350 Vp-p to 2300 Vrms AC for 1 minute).
Options and Accessories
A wide range of optional accessories are available to enhance the functionality of the midi LOGGER series, including:
- Input Terminals (Multi-input B-564, Withstand voltage B-565)
- Extension Base Units (B-566) and Cables (B-567)
- Battery Pack (B-569)
- Input/Output Cable (B-513), DC Drive Cable (B-514)
- Humidity Sensor (B-530)
- Various Digital Sensors (GS-TH, GS-3AT, GS-CO2, GS-LXUV, GS-4VT, GS-4TSR, GS-DPA-AC)
- AC Current Sensors (GS-AC50A, GS-AC100A, GS-AC200A)
- Dual Port Adapter (GS-DPA)
- Shunt Resistor (B-551-10)
- AC Power Adapter (ACADP-20)
- Mounting Brackets (B-570, B-540)
Software Specifications for PC (GL100_240_840-APS)
- Supported OS: Windows 10, 8.1, 8, 7, Vista (32/64-bit).
- Supported Devices: GL840 (USB, Ethernet), GL240 (USB), GL100 (USB).
- Functions: Control GL series units, real-time data capture, data replay, data format conversion.
- Supported Units & Channels: Up to 1000 channels total, up to 4 groups.
- Settings Control: Input condition, capturing condition, trigger/alarm condition, report generation.
- Data Saving: To PC (real-time, GBD or CSV format) or to GL unit (SD card, GBD or CSV format).
- Displayed Information: Y-T waveform, digital values, reports, X-Y graphs, dual display (current/past), statistical calculations, bar charts.
- File Operation: Convert GBD to CSV, merge data files by time axis or as additional channels.
- Warning Function: Email notifications for alarms.
- Statistical Calculation: Maximum, Minimum, Average during capture.
- Report Function: Automatic daily or monthly reports.
Important Notes:
- For correct and safe equipment usage, read the user manual.
- Ensure proper grounding to avoid malfunction or electric shock.
- Data files on the instrument are not guaranteed against loss due to equipment or PC failure; back up data regularly.
- Brand names and product names are trademarks of their respective owners.
- Specifications are subject to change without notice. Refer to the website or contact a representative for the latest information.