Evolved, Simple, Portable, Versatile
The Graphtec GL860 is an isolated multi-channel data logger designed for flexibility and ease of use. It offers 4 terminals for expanded connectivity and features new cloud access capabilities.
Key Features:
- Simple, Portable, Versatile design
- 4 Terminals for More Flexibility
- New Features including Cloud Access
New Features
Cloud Access Services:
- Cloud Server Service: Store data on Graphtec cloud servers.
- Remote Control Service: Remotely control the GL860 via the internet.
- Data Storage Service: Store recorded data on a server.
- *Additional charge for use. *Offered in limited areas only.
Enhanced Functionality:
- Alarm History Function: Easily search event dates and history.
- Enhanced CH to CH Calculation: New calculation functions added.
- Memory Loop Function: Enables recording for longer periods of time.
- Faster Sampling Interval: Twice as fast as previous models.
- CH Copy Function: Easy setup by copying amp settings for the target channel.
- Support Modbus: Communication function with sequencer by Modbus TCP.
Maximum Sampling Interval:
Achieve a maximum sampling interval of 5ms by limiting the number of channels.
Sampling Interval | 1ch | 2ch | 4ch | 10ch | 20ch | 50ch | 100ch | 200ch |
---|---|---|---|---|---|---|---|---|
5ms | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | |||
10ms | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ||
20ms | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | |
50ms | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
100ms | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ | ✔️ |
250ms | ✔️ | ✔️ | ✔️ | ✔️ | ||||
0.5s | ✔️ | ✔️ | ✔️ | |||||
1s | ✔️ | ✔️ |
*Settings required.
User Friendly Features
- 7" Color LCD Display (WVGA: 800 x 480 dots)
- 8GB Internal Memory, SDHC up to 32GB
- Wide Voltage Ranges: 20mV to 100 Vdc & 1-5 Vdc full scale
- Support for Thermocouples (K, J, E, T, R, S, B, N, C) and RTD
- 4 Pulse or Logic Inputs, 4 Alarm Outputs
- Sampling Intervals from 10ms to 1H
- Independent start/stop triggers & external trigger
- Record data to GBD or CSV file format
- USB 2.0, Ethernet, and optional Wi-Fi capability
- Compatible with GL28-APS / GL-Connection SW GUI / G-Remote
- Independent input type, alarm, trigger, and EU scaling per channel
Long Time Recording Available (Built-in 8GB Memory or SD Card)
*Sampling interval is limited by the number of channels in use.
Sampling Interval | 5ms | 10ms | 50ms | 100ms | 200ms | 500ms | 1s | 10s |
---|---|---|---|---|---|---|---|---|
GBD format | 15 days | 24 days | 47 days | 54 days | 108 days | 270 days | 366+ days | 366 days |
CSV format | 1 day | 3 days | 8 days | 11 days | 22 days | 55 days | 111 days | 366+ days |
Terminal Options
The GL860 supports various input terminals for different measurement needs. Terminals are sold separately.
Terminal | Number of CHs | Measuring Voltage | Temperature | Humidity | Max. input voltage | Volt Measurement Accuracy | Dimensions (approx.) | Weight (approx.) |
---|---|---|---|---|---|---|---|---|
20CH High Accuracy, High Isolation Terminal (B-565) | 20ch/per terminal | 20mV-100V | Thermocouple K, J, E, T, R, S, B, N, C (old: W(WRe5-26)) | 0-100% (Optional Humidity Sensor B-530 required) | 20mV - 2V Range: 60Vp-p (between input terminal and (+) / (-) terminal), 5V - 100 V range: 110Vp-p (between input terminal and (+) / (-) terminal) | ±(0.05% of F.S. + 10μV) | 240x166x52.5mm (exclude protrusion) | 1035g (without AC adapter & battery) |
30ch Screwless Input Terminal (B-563 SL-30) | 30ch/per terminal | (RTD cannot be connected) | RTD (*three-wire system only) Pt100, JPt100, Pt1000 (IEC751) | N/A | 600Vp-p (between input terminal and input terminal) | ±0.1% of F.S. | 240x158x52.5mm (exclude protrusion) | 1010g (without AC adapter & battery) |
20ch Screwless Input Terminal (B-563 SL) | 20ch/per terminal | 20mV-100V | (RTD cannot be connected) | N/A | 60Vp-p (between input terminal and input terminal) 300Vp-p (between input terminal and GND) | ±0.1% of F.S. | 240x158x52.5mm (exclude protrusion) | 1010g (without AC adapter & battery) |
20ch Screw Input Terminal (B-563) | 20ch/per terminal | 20mV-100V | (RTD cannot be connected) | N/A | 60Vp-p (between input terminal and input terminal) 300Vp-p (between input terminal and GND) | ±0.1% of F.S. | 240x158x52.5mm (exclude protrusion) | 1010g (without AC adapter & battery) |
*When using B-565 with other terminals, the lower withstand voltage will be applied.
*Weight and Dimensions Values include GL860.
GL860 Main Unit Specifications
Item | Description |
---|---|
Number of analog inputs | Maximum 200ch available for 1 terminal (20ch/30ch) or extension unit. |
External input Number of channels (*1) | Trigger of Sampling (1 channel), or External Sample Inputs 1ch |
Pulse input | Logic / Pulse (4 channel). Revolutions mode, Counts mode, Inst. mode. Maximum input frequency: 50kHz. Maximum number of count: 50kC/sampling. |
External output (*1) | Alarm output: 4ch |
Sampling interval | 5ms-1h (5ms-50ms: voltage only, limited number of CH), external signal. |
Scaling function | 4 points can be set for each channel. The temperature range scaling function is available. |
A/D converter | ΔΣ type, 16Bit (effective resolution: 1/40,000 of ± range). |
PC I/F | Ethernet (10BASE-T/100BASE-TX), USB 2.0 (Hi-SPEED), Wireless LAN (Option). |
Storage media (*2) | Built-in memory: approx. 8GB, SD card slot: 1. |
Data format | GBD, CSV. |
Recording mode | Default, Ring, Relay. |
Other functions | Calculation function, Trigger, Alarm function, Data backup function (*3). |
Display | 7-inch TFT color LCD (WVGA: 800 x 480 dots). |
Operating environment (including terminals) | 0-45°C, 5-85% RH. (0 to 40°C when operated in batteries / 15 to 35°C when a battery is charging). |
Power supply AC adapter | AC100-240V / 50-60Hz. |
DC input | DC8.5-24V (Option: B-514 is required). |
Battery pack | DC7.2V (2875 mAh) 2 packs can be mounted (Optional item). |
Power consumption | 38VA or lower (when using the AC adapter, LCD ON, recharging battery, AC100V). |
Dimensions [WxDxH] (approx.) | (*Refer to terminal specifications). |
Weight (approx.) | (*Refer to terminal specifications). |
Vibration resistance | Equivalent to Automobile parts Type 1 Class A. |
*1: Input/Output cable for GL (option B-513) is required.
*2: Recorded in 2GB per file, SD cards available, Supported SDHC, up to approx. 32GB memory.
*3: If the ring setting and external sampling function is ON, the backup function is not available.
Options and Accessories
Item | Model | Description |
---|---|---|
GL Wireless LAN Unit | B-568 | Standard: IEEE802.11 b/g/n. Approx. Communication Distance: 40m. |
20CH High Accuracy, High Isolation Terminal | B-565 | Analog input terminal. |
30CH Screwless Input Terminal | B-563 SL-30 | Analog input terminal. |
20CH Screw Input Terminal | B-563 | Analog input terminal. |
20CH Screwless Input Terminal | B-563SL | Analog input terminal. |
Base unit for input terminal | B-566 | Used for channel expansion. |
Shunt resistor 250 Ω | B-551-1 | ±250 Ω (0.1%), Rated power of 1 W. |
Connection cable for extension terminal (50cm) | B-567-05 | Expansion cable (50cm). |
Connection cable for extension terminal (2m) | B-567-20 | Expansion cable (2m). |
Battery Pack | B-573 | 1 pack: 7.2V (2875 mAh). 2 packs can be mounted. |
Input/Output cable for GL series | B-513 | Input-Output cable for pulse-logic-alarm, 2m. |
DC drive cable | B-514 | External DC cable, 8.5-24vdc, 2m. |
Humidity sensor (*4) | B-530 | 3 m long (with power plug). Operating temperature range: -25°C to +80°C. |
Type K TC adapter | TC-K-5 | Type K mini-connector-spade lugs, 12", 5 pk. |
Type T TC adapter | TC-T-5 | Type T mini-connector-spade lugs, 12", 5 pk. |
Software and Cloud Services
PC Software
- GL-Connection: Integrated application software for the GL series.
- GL28-APS: Application software to connect GL series and PC. Allows for main unit settings, data recording, storage, and playback.
G-REMOTE Cloud Service
(*Additional charge for use)
Item | Description |
---|---|
Supported OS (*5) | Windows 11/10. (OS no longer supported by manufacturer are not supported by Graphtec). |
Supported WEB browser | Google Chrome (recommended), Microsoft Edge, Firefox (*Internet browser supporting HTML5). |
Service content |
|
*For more information about product, please check the web site.
Calibration and Support
Calibration (Production Data)
Item | Code | Description |
---|---|---|
NIST calibration with cert. | NIST-CAL | NIST calibration with certificate. |
NIST calibration with cert & data | NIST-CAL-DATA | NIST calibration with certificate and data. |
ISO-17025 calibration for GL860 | ISO-17025-860 | ISO-17025 calibration for GL860. |
*Documents ordered at the time of product purchase are data at the time of manufacture.
*Please visit calibration services section of our website for details.
Important Notes:
- Due to the possibility of equipment or PC failure, the data files on the instrument will not be guaranteed to be held on the memory. Please make a backup of data whenever possible to avoid data loss.
- Brand names and product names listed are trademarks or registered trademarks of their respective owners.
- Items mentioned are subject to change without notice. For more information about product, please check the web site or contact your local representative.
- For using equipment correctly and safely: Before using it, please read the user manual and then please use it properly in accordance with the description. To avoid malfunction or an electric shock by current leakage or voltage, please ensure a ground connection and use according to specifications.
CE Mark
Model Number: GL860_KE11005_1D