Streamlining your performance.

ZEISS OPMI Sensera

S7 / OPMI Sensera®

Website: zeiss.com/OPMI-Sensera

Ease of Use

Since ZEISS introduced the first surgical microscope in 1953, the field of otorhinolaryngology has been at the forefront of microsurgery. In collaboration with surgeons, ZEISS has developed trend-setting visualization solutions, providing the functionalities ENT surgeons expect.

OPMI Sensera® from ZEISS enables the surgeon to effortlessly move the system into a comfortable position for performing ear, nose, or throat surgery. At the push of a button, the innovative balancing system ensures that the microscope is perfectly balanced, even when equipped with maximum accessories.

For the ear, precision is key

ZEISS OPMI Sensera is optimized for the delicate and precise techniques demanded for surgical ear procedures. This surgical microscope offers a flexibility in positioning that also ensures high comfort for the extreme approaches often required for skull base surgeries.

Just follow your nose

Varioskop® optics, combined with the tiltable tube, enable the surgeon to maintain an ergonomic posture, particularly in paranasal sinus surgery, where the working distance changes frequently. Surgeons can also refocus at the push of a button and easily adjust the spot size of the illumination to see down narrow nasal passages.

Preserving functionality in throat procedures

CO2 lasers are often used in surgery on the larynx. Because it is so compact, ZEISS OPMI Sensera makes it possible to operate comfortably while achieving the necessary approach angles for laser microsurgery. The optional external fine focus allows surgeons to synchronize the focus of the surgical microscope and the laser without disrupting the procedure.

Image Description: Two images depicting surgeons performing procedures using the OPMI Sensera microscope.

Optical Excellence

Image Description: Image showing a surgical view of an acoustic neuroma. Source: Gruppo Otologico-Piacenza, Prof. Dr. Sanna.

Image Description: Image showing a surgical view of a left middle ear approach for a stapes procedure. Source: Barrow Neurological Institute, Dr. Peter A. Weisskopf.

As demands continue to grow in ENT surgery, quality optics and what they provide in terms of image quality, resolution, and color rendition become much more important. A Varioskop that provides a working distance of 200 – 415 mm coupled with the 1:6 zoom system ensures that the apochromatic optics of ZEISS OPMI Sensera can readily accommodate any surgical application in ENT. The Superlux® xenon illumination ensures that the finest details are visible in true color.

Focused images at the push of a button

The video system with SpeedFokus simplifies procedures by quickly and precisely focusing the optics at the push of a button. The surgical workflow becomes more efficient as surgeons completely concentrate on the treatment. Manual, time-consuming focusing is a thing of the past.

Complete documentation

ZEISS provides the entire chain of video components from co-observation to documentation. The 1Chip HD Camera is optimally aligned with ZEISS apochromatic optics and enables the display of high-definition images with high color fidelity during surgical procedures to further enhance the clinical workflow. The handgrip allows the rapid capture of high-resolution still images and videos for documentation and scientific presentation. To support efficient data handling, digital images can be automatically stored to a network.

Adaptability is key

Combined with ZEISS OPMI Sensera, laser micro-manipulators permit the use of different, easily mounted lasers.

Integration

Clean design lines, form, and functionality define the ZEISS OPMI Sensera. Internal zoom and focus, Superlux xenon illumination, and the optional, workflow-integrated HD video chain are internalized, eliminating cable clutter and potential cable damage while making it easier to clean.

Image Description: Image of the ZEISS OPMI Sensera microscope mounted on a floor stand, featuring the '[Red Dot Design Award]' logo.

Feather-light maneuverability

The floor stand has four freely rotating casters, which makes repositioning in the OR or transferring between different rooms easy. ZEISS OPMI Sensera is also available on the S7 ceiling mount with a rigid column or an optional lifting column.

Personalized settings

In today's increasingly crowded ORs, ZEISS OPMI Sensera easily and quickly adapts to the varying procedural needs of the ENT surgeon. The touch of a button on the S7 graphical interface quickly configures an optimized setup for ear, nose, or throat surgery. Plus, three surgeons can store their personal preferences for magnification, focus, and illumination, making pre-surgical setup a snap.

Options

Thanks to the ZEISS building block principle, OPMI Sensera from ZEISS can be easily configured with the accessories required for different procedures.

Ergonomic design and operating comfort

Optics and illumination

Digital visualization

Technical Data

S7 / OPMI Sensera® from ZEISS

FeatureSpecification
MagnificationMotorized ZEISS zoom, 1:6 ratio, adjustable via handgrips or foot control panel✔️
Eyepieces10x wide-field eyepieces✔️
12.5x wide-field eyepieces✔️
TubesTiltable Tube 0 – 180°, f = 170 mm✔️
Straight Tube, f = 170 mm✔️
Foldable Tube f170/f260, including PROMAG function for additional 50% magnification and integrated rotate function✔️
FocusInternal, motorized, continuously adjustable, triggered via handgrip or foot control panel✔️
SpeedFokus✔️
IlluminationSuperlux 180 W xenon light source✔️
100 W halogen illumination✔️
System operationMultifunctional programmable handgrips✔️
Wired 14 functions foot control panel✔️
Wireless 14 functions foot control panel✔️
Suspension systemsFloor stand✔️
Ceiling mount with rigid column✔️
Ceiling mount with lifting column✔️
Video1Chip HD Camera✔️
HD video recorder✔️
HD monitors✔️
Adaptation of consumer (SLR) photo/video camera✔️
Laser attachmentInterface for laser micro-manipulator✔️
Other optionsStereo co-observer✔️
External motorized fine focus device for laser use✔️
OPMI Drapes sterile with VisionGuard® lenses✔️
Sterilizable asepsis caps✔️
Instrument tray on floor stand✔️

Image Description: Diagram illustrating the S7 Floor stand with dimensions.

Image Description: Diagram illustrating the S7 Ceiling mount with a rigid column, showing dimensions.

Image Description: Diagram illustrating the S7 Ceiling mount with a lifting column, showing dimensions.

Models: S7, S7 OPMI Sensera Surgical Microscope, OPMI Sensera Surgical Microscope, OPMI Sensera, Surgical Microscope, Microscope

File Info : application/pdf, 8 Pages, 1.34MB

PDF preview unavailable. Download the PDF instead.

OPMI-Sensera-Brochure-en-INT-30-010-0421V

References

Adobe PDF Library 15.0

Related Documents

Preview ZEISS EXTARO 300: Advanced Surgical Microscope for Enhanced Visualization and Efficiency
Discover the ZEISS EXTARO 300, a state-of-the-art surgical microscope designed to boost efficiency and simplify visibility in procedures like tympanoplasty, myringotomy, stapedectomy, mastoidectomy, and transoral laser surgery. Featuring innovative MultiSpectral Mode and NoGlare Mode for superior anatomical detail, single-handed operation, and digital data management with the ZEISS Connect App.
Preview ZEISS OPMI LUMERA 300: Best-in-Class Surgical Microscope for Cataract and Retina Surgery
Discover the ZEISS OPMI LUMERA 300, a state-of-the-art surgical microscope offering exceptional optics, BrightFlex LED illumination, and superior quality for cataract and retina procedures. Learn about its features, configurations, and benefits for enhanced visualization and patient comfort.
Preview BLUEMIXS 180 Injector Handling Instructions | ZEISS
Comprehensive handling instructions for the BLUEMIXS 180 injector by ZEISS, detailing the steps for loading and injecting intraocular lenses (IOLs).
Preview ZEISS Pickup Order Form
Official pickup order form for ZEISS logistics services, detailing shipment information, recipient and billing addresses, and preferred shipping options.
Preview ZEISS CT LUCIA 202 IOL Injector Handling Instructions
Detailed handling instructions for the ZEISS CT LUCIA 202 intraocular lens (IOL) injector system, covering preparation, loading, and implantation steps for ophthalmic surgery.
Preview VISCOJECT-BIO 2.2 Injector Set Handling Instructions for 4-Point Haptic IOLs | ZEISS
Detailed handling instructions for the ZEISS VISCOJECT-BIO 2.2 Injector Set, designed for 4-point haptic IOLs. Learn step-by-step usage for ophthalmic procedures.
Preview ZEISS SKYJET Injector Set: Handling Instructions for CT ASPHINA 603P and CT SPHERIS 203P
Detailed handling instructions for the ZEISS SKYJET Injector Set, designed for preloaded CT ASPHINA 603P and CT SPHERIS 203P intraocular lenses. Learn step-by-step preparation and usage for ophthalmic procedures.
Preview ZEISS CALLISTO eye 3.6: Quick Guide to Reference Image Matching
A comprehensive quick guide for ZEISS CALLISTO eye 3.6, detailing the process of matching the reference image for accurate toric IOL alignment. Learn about image capture, microscope requirements, patient data import, and alignment procedures.