Installation Verification
Before starting, please verify the installation according to the following points:
- Visually check that the blade holders are not deformed.
- Ensure the blades are correctly fixed. To do this, use a reference point to check the blades. Place a ruler vertically against the ceiling to measure the height of the blades. Note the distance between the ceiling and the tip of the blades. Keep the ruler in the same position and manually rotate the blades. All measurements should be identical.
- Verify there is no play in the blade fixing.
- Ensure there is no play in the rod and the support.
- Listen for the beep when the circuit breaker is switched on.
Remote Control 555011
Insert 2 AAA 1.5Vdc batteries into the remote control before use.
Button Functions:
- On/Off Button: Short press to turn the fan off. Short press to turn the light on/off.
- Speed Control (1-6): 1 = low speed, 6 = maximum power.
- Summer Mode (Sun Icon): Automatic mode with speed adjustment according to room ventilation.
- Winter Mode (Snowflake Icon): Air circulation downwards for a cooling effect.
- Light Temperature (Lightbulb Icon): Select the color temperature of the light.
- Light Intensity (Plus/Minus Icons): Decrease/Increase light intensity.
- Timer (30', 2H, 4H Icons): Timer setting. The fan will turn off after the selected operating period. Light control is independent.
Pairing, Unpairing, and Synchronization:
Button | When? | Duration of Press |
---|---|---|
Pairing (Summer Icon) | Within 10s after power is restored | 5 seconds |
Unpairing (Winter Icon) | Within 10s after power is restored | 5 seconds |
Synchronization (Fan Icon) | Anytime while powered on | 5 seconds |
Synchronization: Speed 1 / Summer Mode / Minimum Power / 4000K. Synchronize multiple fans using the same control system.
Switch 555010
Insert 1 CR2032 battery into the remote control before use.
Button Functions:
- On/Off Button (Circle Icon): Short press to turn the fan on/off at the last chosen speed.
- Speed Control (Plus/Minus Icons): Short press to increase/decrease fan speed. 6 speeds available.
- Timer (30', 2H, 4H Icons): Timer setting. The fan will turn off after the selected operating period. Light control is independent.
- Summer Mode (Sun Icon): Air circulation downwards for a cooling effect.
- Winter Mode (Snowflake Icon): Air circulation upwards to bring down heat accumulated at the ceiling, without creating a direct draft.
- Light On/Off (Lightbulb Icon): Short press to turn the light on/off.
- Light Intensity (Plus/Minus Icons): Decrease/Increase light intensity.
- Light Temperature (Lightbulb with waves Icon): Select the color temperature of the light.
Pairing, Unpairing, and Synchronization:
Button | When? | Duration of Press |
---|---|---|
Pairing (Summer Icon) | Within 10s after power is restored | 5 seconds |
Unpairing (Winter Icon) | Within 10s after power is restored | 5 seconds |
Synchronization (Fan Icon) | Anytime while powered on | 5 seconds |
Synchronization: Speed 1 / Summer Mode / Minimum Power / 4000K. Synchronize multiple fans using the same control system.
Switch 555009
Connect the driver to the 230Vac using the quick connector to power the remote control.
Button Functions:
- On/Off Button (Circle Icon): Short press to turn the fan on/off at the last chosen speed.
- Speed Control (Plus/Minus Icons): Short press to increase/decrease fan speed. 6 speeds available.
- Timer (30', 2H, 4H Icons): Timer setting. The fan will turn off after the selected operating period. Light control is independent.
- Summer Mode (Sun Icon): Air circulation downwards for a cooling effect.
- Winter Mode (Snowflake Icon): Air circulation upwards to bring down heat accumulated at the ceiling, without creating a direct draft.
- Light On/Off (Lightbulb Icon): Short press to turn the light on/off.
- Light Intensity (Plus/Minus Icons): Decrease/Increase light intensity.
- Light Temperature (Lightbulb with waves Icon): Select the color temperature of the light.
Pairing, Unpairing, and Synchronization:
Button | When? | Duration of Press |
---|---|---|
Pairing (Summer Icon) | Within 10s after power is restored | 5 seconds |
Unpairing (Winter Icon) | Within 10s after power is restored | 5 seconds |
Synchronization (Fan Icon) | Anytime while powered on | 5 seconds |
Synchronization: Speed 1 / Summer Mode / Minimum Power / 4000K. Synchronize multiple fans using the same control system.
Installation Recommendations - Switch
1x Switch for Max 5 Fans
Standard Switch:
Maximum Range: Theoretically, there is no limit to the number of fans that can be controlled simultaneously, provided they are all within the remote control's predefined range. However, we recommend a maximum of 5 fans per remote control to ensure coverage of large areas and avoid desynchronization.
2x Switches per Fan
Combo Switch:
Maximum Range: We also recommend a range of up to 15 meters between the remote control and the furthest fan. This distance can vary depending on the environment and "obstacles" that may block the signal from the remote control. You are nevertheless certain to transmit the signal if the fan is within 15 meters of the remote control in clear line of sight.
2x Switches for Max 5 Fans
Combo Switch:
Maximum Range: Control up to 5 fans with 2 switches, maximum distance of 15 m for the furthest fan.
Installation Recommendations - Remote Control
1x Remote Control for Max 3 Fans
Standard Remote Control:
Maximum Range: Theoretically, there is no limit to the number of fans that can be controlled simultaneously, provided they are all within the remote control's predefined range. However, we recommend a maximum of 5 fans per remote control to ensure coverage of large areas and avoid desynchronization.
2x Remote Controls per Fan
Combo Remote Control:
Maximum Range: We also recommend a range of up to 15 meters between the remote control and the furthest fan. This distance can vary depending on the environment and "obstacles" that may block the signal from the remote control. You are nevertheless certain to transmit the signal if the fan is within 15 meters of the remote control in clear line of sight.
Operation
Summer Mode (Sun Icon):
In summer, the fan blades rotate in a direction that directs air downwards. This creates a refreshing breeze in the room.
Winter Mode (Snowflake Icon):
In winter, the blades rotate in the opposite direction. This allows warm air accumulated at the ceiling to be brought down and evenly distributed in the room, without creating a direct draft.
Certified Performance:
Your selection of fan speeds will ventilate rooms according to needs, while also achieving significant energy savings. These energy savings impacts will translate into a reduction in your carbon footprint and your electricity bill. High-speed air circulation will also help to deter mosquitoes.
Speed | Power (W) | Airflow (m³/H) | Rotation Speed (rpm) | Comfort 0.5m/s (m²) | Comfort 1.0m/s (m²) | Max Air Speed (m/s) | Acoustic (dB) |
---|---|---|---|---|---|---|---|
1 | 6.42 | 5605 | 98 | 3.11 | 1.55 | 1.6 | 18.6 |
2 | 8 | 6710 | 114.4 | 3.72 | 1.86 | 1.86 | 21.5 |
3 | 12 | 7815 | 130.8 | 4.34 | 2.17 | 2.12 | 24.2 |
4 | 18 | 8919 | 147.2 | 4.95 | 2.47 | 2.38 | 27 |
5 | 25 | 10024 | 163.6 | 5.56 | 2.78 | 2.64 | 29.8 |
6 | 31 | 11129 | 180 | 6.18 | 3.09 | 2.9 | 32.6 |
Optimized Classroom Treatment Principle:
The diagram shows a classroom layout with different zones for acoustic tiles, lighting, and support for BAP (presumably a type of lighting or sound system). The zones are color-coded to indicate their function.
Troubleshooting Common Problems
Symptom | Origin(s) of the Problem(s) | Verification Step(s) | Solution(s) |
---|---|---|---|
Remote Control (On/Off, Settings) | Remote control batteries discharged | Check batteries | Replace batteries |
Defective transmitter kit + remote control | Check electrical connections | Change the remote control kit + remote control, or replace the fan | |
Incorrect electrical connections | Verify electrical connections | - | |
Fan does not start | Power outage | Verify power supply and circuit breaker | Turn off power for 1 minute and restart the fan |
Incorrect electrical connections | Verify electrical connections | Change the transmitter kit + remote control, or replace the fan | |
Disconnected wires at the terminals | Verify wiring and blade fixings. | Short the connection wires at the terminals | |
Cabling problems on the fan | Verify wiring | Contact the retailer to replace the fan | |
Motor HS (High Speed/Service) | Verify power supply and circuit breaker | Turn off power for 1 minute and restart the fan | |
Fan moves but does not start | Incomplete commissioning | Verify wiring | Change the transmitter kit + remote control, or replace the fan |
Incorrect electrical connections | Verify electrical connections | Repair or replace defective components | |
DC = Motor, power supply, or remote control | Verify power supply and circuit breaker | Short the connection wires at the terminals | |
Cabling problems on the fan | Verify electrical connections | Contact the retailer to replace the fan | |
Motor HS (High Speed/Service) | Verify power supply and circuit breaker | Repair or replace defective components | |
DC = Motor, power supply, or remote control | Verify power supply and circuit breaker | Repair or replace defective components | |
Abnormal noises | Worn or dusty motor | Verify accumulated dust | Perform maintenance on the fan |
Stuck screws in the motor housing | Verify fixing screws | Replace screws if necessary | |
Motor HS (High Speed/Service) | Verify power supply and circuit breaker | Contact the retailer to replace the fan | |
Vibrations | Imbalance, loose fixings | Tighten fixings for cups/blades | Balance with a balancing kit or replace damaged parts |
Defective support or ball joint | Check the ball joint and support | Fix correctly and use a balancing kit | |
Light does not work | LED module not connected correctly | Verify electrical connections | Replace the LED module |
Defective transmitter control module | Verify electrical connections | Change the transmitter kit + remote control | |
Some LEDs remain on after turning off the light | Significant leakage current | Verify the grounding of connections and wiring. | Isolate electrical connector. |
LED PCB mounting magnets | Verify the grounding of the LED module connections and | Isolate the LED PCB mounting magnets | |
Insufficient airflow | Defective receiver | Verify receiver operation | Change the receiver |
Inverted rotation direction | Check summer/winter mode on remote control | Follow the instructions in the manual | |
Screen broken | Damage during transport or installation | Check for damage during transport or installation | Replace the screen |
Height under blade too short | Low ceiling installation (240 cm) | Ceiling installation (240 cm) | Shorten the rod by 1 cm |
Blades too close to the ceiling | Inclined ceiling (>4°) | Inclined ceiling (>4°) | Use a longer rod |